Installing a 3-wire conduit
• Aluminum building wire may be used but it must be rated for the correct
amperage and voltage. Connect the wires as described below.
• The wire you use, the location and enclosure of splices, etc., must conform to
good wiring practices and local codes.
1
. Loosen the 3 lower terminal screws from
the terminal block.
2
. Insert the center bare wire (white/neutral)
tip through the bottom center terminal
block opening. On certain models, the
wire will need to be inserted through the
ground strap opening and then into the
bottom center block opening.
3
. Insert the two side bare wire tips into the
lower left and the lower right terminal
block openings.
4
. Tighten the screws until the wire is firmly
secured (35 to 50 inch-lbs.). Do not over-
tighten the screws since it could damage
the wires.
5
. Go to
Step 5
on page 15 to continue
with the installation.
White
Black
Red
Ground
strap
Neutral
terminal
Wire tips
Red
White
Black
English - 13
02
CONNEC
TING THE POWER