13
ENGLISH
Connecting 2 or more wired remote controller
Outdoor unit
COM1(F1, F2)
COM1(F1, F2)
COM2(F3, F4)
COM2(F3, F4)
COM1(F1, F2)
Hydro
unit/
Hydro
unit HT
Wired remote
controller
Wired remote
controller
Hydro
unit/
Hydro
unit HT
Hydro
unit/
Hydro
unit HT
Unit No. 1
Unit No. 2
Unit No. 3
Hot water tank sensor
Hot water tank
ex)
Unit No.
Water tank sensor cable wiring
05 Series install option SEG24 setting
1
Connected
0
2
Connected
0
3
Not connected
1
•
If the hydro unit/ hydro unit HT needs to share the temperature value of the hot water tank, it must be
connected to the same remote controller that is connected to other hydro unit/ hydro unit HT that is connected
directly to the hot water tank with a temperature sensor. Also, when there are more than 2 wired remote
controllers, they should be connected to same communication line.
•
When multiple units (hydro unit/hydro unit HT) are connected to one wired remote controller, type of the units
must be same.
- Different types of units (hydro unit/ hydro unit HT) should not be connected to the same wire remote
controller
CAUTION