background image

ENGLISHENGLISH

ESP

AÑOL

FR

ANÇ

AIS

IT

ALIANO

POR

TUGU

ÊS

DEUT

SCH

USER’S MANUAL

Wired Remote Controller

MWR-WS00

System Air Conditioner

DB98-25179A(1)

S

E

F I

D

P

G R A

EΛΛHNIK

A

RUSSIAN

MWR-WS00_IB_E_25179.indd   23

2006-03-28   ソタネト 3:27:13

Summary of Contents for MWR-WS00

Page 1: ...ENGLISH ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH USER SMANUAL WiredRemoteController MWR WS00 System Air Conditioner DB98 25179A 1 S E F I D P G R A EΛΛHNIKA RUSSIAN ...

Page 2: ...controller Do not operate the remote controller with wet hands Do not install the remote controller in a location where it will come into contact with the combustible gases machine oil sulphide gas etc Do not press buttons with a pointed thing Do not pull or bend the wired remote controller cable excessively Do not use this wired remote controller for other purpose Do not spray an insecticide or o...

Page 3: ...E 10 SELECTING THE QUIET MODE 11 SELECTING THE SLEEP MODE 12 ADJUSTING THE AIRFLOW DIRECTION 13 CHECKING THE ROOM TEMPERATURE 14 SETTING THE 7 DAY SCHEDULE 15 SETTING AND CANCELING A HOLIDAY SCHEDULE 16 CANCELING DURING SCHEDULE SETUP 17 DELETING A SCHEDULE 17 RESETTING THE CLOCK 18 INITIALIZING THE REMOTE CONTROLLER 19 LOCKING THE REMOTE CONTROLLER 19 SETTING THE AUTO STOP FUNCTION 20 SETTING THE...

Page 4: ...the filter and turn off the display when the button is pressed Restricted will be displayed if the button is pressed for duct type indoor units Restricted will be displayed if the indoor unit does not support the function of the pressed button Note 7 day schedule time setup Indoor temperature Check button Schedule clock Operating mode Fan speed Time schedule reset button Filter reset button Mode s...

Page 5: ...contain much valuable information on using your wired remote controller Please take the time to read them as they will help you take full advantage of the unit s features In the manual you will find a series of step by step procedures for each function available The illustrations in the step by step procedures use 3 different symbols PRESS PUSH HOLD DOWN ...

Page 6: ...n The air conditioner has a built in protection mechanism to prevent the unit from being damaged when it is started immediately after being Plugged in Stopped The air conditioner will start up after 3 minutes 2 To select the AUTO mode press the button until Auto is displayed on the remote controller Result The air conditioner will run in AUTO mode 3 To adjust the temperature press the buttons to s...

Page 7: ... up after 3 minutes 2 To select the COOL mode press the button until Cool is displayed on the remote controller Result The air conditioner will run in cooling mode 3 To adjust the temperature press the buttons to set the desired temperature The temperature can be set between 18 C and 30 C Result The temperature is adjusted by 1 C when the buttons are pressed The air conditioner will start cooling ...

Page 8: ... HEAT mode press the button until Heat is displayed on the remote controller Result The air conditioner will run in heating mode 3 To adjust the temperature press the buttons to set the desired temperature The temperature can be set between 16 C and 30 C Result The temperature is adjusted by 1 C when the buttons are pressed The air conditioner will start heating if the temperature set is higher th...

Page 9: ... mechanism to prevent the unit from being damaged when it is started immediately after being Plugged in Stopped The air conditioner will start up after 3 minutes 2 To select the DRY mode press the button until Dry is displayed on the remote controller Result The air conditioner will run in dehumidifying mode 3 To adjust the temperature press the buttons to set the desired temperature The temperatu...

Page 10: ...ed when the unit was last used Caution The air conditioner has a built in protection mechanism to prevent the unit from being damaged when it is started immediately after being Plugged in Stopped The air conditioner will start up after 3 minutes 2 To select the FAN mode press the button until Fan is displayed on the remote controller Result The air conditioner will run in fan mode 3 Select the fan...

Page 11: ... the ON OFF button to turn on the indoor unit Do not press the ON OFF button if the remote controller is on Result The air conditioner will be turned on with the mode selected when the unit was last used 2 Select the desired operating mode by pressing the button 3 Press the button to select the Quiet mode Result The air conditioner runs in quiet mode Note Press the button again to exit the Quiet m...

Page 12: ... controller is on Result The air conditioner will be turned on with the mode selected when the unit was last used 2 Select the desired operating mode by pressing the button Note Only cooling and heating mode support the sleep mode 3 Press the button to select the SLEEP mode Result The air conditioner will run in sleep mode The air conditioner will gradually raise or lower the set temperature inter...

Page 13: ...ction cannot be set on duct type indoor units 1 If the indoor unit supports 5 step directions Press the button Select the direction of the airflow The airflow blade can be set to one of the five directions or to swing automatically 2 If the indoor unit does not support 5 step directions Press the button The blade will start swinging Press the button again to stop the blade from swinging and to set...

Page 14: ...utton to check the room temperature Result The room temperature will be displayed for 3 seconds and return to set temperature display Note The room temperature may be slightly different depending on the installation location of the remote controller ...

Page 15: ...me Result Each time the button is pressed the time is increased by 1 hour Each time the button is pressed the time is increased by 1 minute Hold down the button to increase the time by 10 minutes 4 Press the button to select on or off schedule Result or is displayed 5 For on schedules mode temperature and fan speed can be set Result Set the mode temperature and fan speed for the on schedule and th...

Page 16: ...to be set as holiday by pressing the button Result Each time the button is pressed the square box shifts to the right 3 Set the holiday by pressing the button Result The schedules are not deleted but the bar below the day becomes invisible to indicate the schedule will not run Press the button to cancel the holiday Note The bar below the day is invisible if there are no schedules set for that day ...

Page 17: ...enter the schedule setup mode The button does not need to be pressed if the mode is already in schedule setup mode 2 Select the day of the schedule to be deleted by pressing the button Result Each time the button is pressed the square box shifts to the right 3 Select the schedule number to be deleted by pressing the button Result Each time the button is pressed the schedule number increases 4 Pres...

Page 18: ...e by pressing the button and the button Result Each time the button is pressed the time is increased by 1 hour Each time the button is pressed the time is increased by 1 minute Hold down the button to increase the time by 10minutes Set the day by pressing the button 3 Press the button Result The clock and day stop blinking and the time is set ...

Page 19: ...the clock Do not initialize the remote controller unless you want all the schedules to be deleted Locking the Remote controller The remote controller buttons can be locked to prevent children from changing the settings or from pressing the buttons by accident 1 To lock the buttons on the remote controller press the button for 5 seconds until Lock is displayed Result The remote controller buttons a...

Page 20: ...oor unit 1 Press the button for 5 seconds to enter the setup mode Result The wired remote controller will enter the setup mode and the menu will dispaly 2 Press the button to enter the auto stop time setup mode 3 The default time setting is The auto stop time can be set between 0 and 12 hours Note Time is adjusted by 1 hour when the buttons are pressed Press the button to save the auto stop time s...

Page 21: ...nter the setup mode and the menu will dispaly 2 Press the button Result The wired remote controller will display on the menu 3 Press the button to enter the temperature limit setup mode 4 The default lower and upper limits are 16 C and 30 C Set the lower limit first by pressing the button followed by the button and set the upper limit Note Press the button again to set the upper limits Even if the...

Page 22: ......