Default settings
After changing the setting of PCB, make sure to initialize
the system.
- To initialize the system, press the
,
buttons
at the same time for 5 seconds.
If the indoor unit does not support SW5 and SW6
options, indoor unit temperature sensor will be used
regardless of the settings.
You can check the wired remote controller DIP switch
settings in menu 15 of additional functions. (Refer to
page 29)
- You can check it without disassembling the product.
Installing the Wired remote controller (Continued)
Setting the Wired Remote Controller Options
Switch
No.
Switch OFF
Switch ON
SW1 Cooling and Heating
Cooling Only
SW2 Allow wireless remote
controller
Disable the wireless remote
controller
SW3
Master remote
controller
Slave remote controller
SW4 Temperature display : °C
Temperature display : °F
SW5
Use the indoor unit
Temperature Sensor for the
indoor unit control
Use the wired remote
controller Temperature
Sensor for the indoor unit
control
SW6
-
Use the average of the
indoor unit sensor and the
wired remote controller
sensor for the indoor unit
control
SW7 Auto mode enable
Auto mode disable
SW8
-
-
�
��� ��� ��� ��� ��� ��� ��� ���
� � ��� � � � �
MWR-WH00_IM_E_31219-1.indd 7
2009-12-14 ソタタ・9:01:32