background image

Air conditioner

Installation manual

Wired remote controller MWR-WG00JN

 

Thank you for purchasing this Samsung Product. 

 

Before operating this unit, please read this installation manual carefully and retain it for 
future reference.

Summary of Contents for MWR-WG00JN

Page 1: ...er Installation manual Wired remote controller MWR WG00JN Thank you for purchasing this Samsung Product Before operating this unit please read this installation manual carefully and retain it for futu...

Page 2: ...trol with YourWired Remote Controller 10 Controlling the 2 remote controller 13 Initializing YourWired Remote Controller Communication 16 Errors displayed on the Wired Remote Controller 16 Installatio...

Page 3: ...n manual Incorrect installation may cause electric shock or fire The electric work must be done by qualified person according to national wiring regulations and installation guide If an unauthorized p...

Page 4: ...te ControllerInstallation 4 English Wired Remote ControllerInstallation Wired Remote Controller Installation Wired Remote ControllerInstallation External Dimensions Unit mm inch 120 0 4 72 19 0 0 75 1...

Page 5: ...to lift the front cover for removal from the rear cover 2 Arrange the power cable and the communication cable so that they fit in the housing along the edges of the rear cover When the cable is not c...

Page 6: ...or more or more Screw hole Rear cover 9 space of upper side left side space of bottom side screws into the screw holes 4 Connect the communication cables F3 F4 to the terminals of the back of the fro...

Page 7: ...CAUTION A communication cable and the power cable separately Electrical interference can cause the Wired Remote Controller to malfunction When installing yourWired Remote Controller on the wall consid...

Page 8: ...ening torque is greater it may damage the screw thread Tracking YourIndoorUnit from the Wired Remote Controller See the image A 1 Tracking of yourWired Remote Controllerwill automatically start when y...

Page 9: ...indoor unit orventilator ERV When connected to an indoorunit only Outdoor unit Indoor A A A A A Wired Remote Controller Indoor Indoor Wired Remote Controller Wired Remote Controller When connected to...

Page 10: ...ly Using One Wired Remote Controller to control three indoor Units Outdoor unit A A Wired Remote Controller A A A Indoor Indoor Indoor Using One Wired Remote Controller to control indoor units connect...

Page 11: ...rventilator ERV Wired Remote Controller A A Ventilator ERV Ventilator ERV Ventilator ERV A A A NOTE k A k A controlled in group When connecting an indoor unit and a ventilator ERV together Using One W...

Page 12: ...nt outdoor unit and ventilator ERV Outdoor unit Indoor Wired Remote Controller Outdoor unit Indoor A A A Ventilator ERV A NOTE A k A When controlling indoor units and ventilator ERV together in group...

Page 13: ...controller 2 Remote controller is controlling one indoor unit ventilator ERV or one group of indoor units and ventilator ERV with two remote controllers When connected to an indoorunit only Outdoor u...

Page 14: ...n When connected to a ventilator ERV only Wired Remote Controller Main A Masterventilator ERV A Ventilator ERV Wired Remote Controller Sub NOTE For the sub Wired Remote Controller settings please see...

Page 15: ...a ventilator ERV together Outdoor unit Indoor A Wired Remote Controller Main A Wired Remote Controller Sub A Ventilator ERV NOTE A A controlled by the 2 remote controller For the sub Wired Remote Con...

Page 16: ...ote Controllerwill be displayed in the LCD display Wired Remote Controllererrorcodes Indication Description Remarks Communication error between wired remote controller and indoor ERV units after succe...

Page 17: ...s screen for installation service mode appears 3 See the list of additional functions for the Wired Remote Controller on the next page and then select the desired menu Once you have entered the settin...

Page 18: ...ndoor unit Ventilation Auto mode ON OFF ON Cool Heat selection Cool Only Cool Heat Cool Heat Wireless remote controller ON OFF ON 9 Temperature unit Temperature unit Celsius C Celsius C Set temp Unit...

Page 19: ...al of the connected indoor unit or ventilator Installation option1 3 Installation option 2 3 A A 00 to15 A A to F Device Information Wired Remote Controller code Program version Touch code Touch IC co...

Page 20: ...Indoor unit status information Central control ON OFF Drain pump ON OFF Electric heater ON OFF Hot water coil ON OFF External control ON OFF ON OFF Filter replacement cycle 2000 hr 1000 hr Heating ca...

Page 21: ...ifferent temp setting ON OFF alternation operation air cooling 5 to15 C 15 C ERV Plus Cold air prevention ON OFF Humidification when Heating thermo off ON OFF Fan operation in Defrost ON OFF Humidific...

Page 22: ...TE Address is displayed in hexadecimal Please refer to the following table Hexadecimal Decimal Hexadecimal Decimal Hexadecimal Decimal 00 0 10 16 20 32 01 1 11 17 21 33 02 2 12 18 22 34 03 3 13 19 23...

Page 23: ...e controller program change the file name to A 9 and then download to microSD Card 3 Insert the microSD Card with the Wired Remote Controller active and then reset the system For system reset press th...

Page 24: ...load starts again after finishing the reset NOTE When you reset the Wired Remote Controllerwhile the microSD Card is removed the above message appears on the screen in standby mode When you reset the...

Page 25: ...25 English Installation Service mode Memo...

Page 26: ......

Reviews: