•   If you want to cancel your weekly schedules while you are 

setting them, then press the 

ESC

 button.

•   If “Central control” is set, then you can still set a weekly 

schedule, but it won’t be actually executed.

11. After pressing the 

[

]

 button, select a fan speed. 

  

   You can only use this for air conditioner on-operation scheduling or when 

the operational mode is in Cool/Fan/Heat. 

  

    Press the 

[

]/[

]

 buttons repeatedly to toggle the fan speed in order of 

(Low )

(Medium)

(High)

(Auto). If Auto operation or Dry operation is 

selected, then you can’t set the fan speed. 

12. After pressing the 

[

]

 button, select the ventilator(ERV) related operation mode. 

  

   You can only use this for Heat-Ex on-operation scheduling.

  

     Press  the 

[

]/[

]

 button, select the ERV related operation mode: 

(Heat EX)

(Quiet)

(Away)

(Bypass)

(Auto)

(Purifi er)

(Heat-Ex / Purifi er)

(By-Pass / Purifi er)

(Auto / Purifi er)

13. After pressing the 

[

]

 button, select a fan speed for ventilator(ERV). 

  

   You can only use this for Heat-Ex on-operation scheduling.

  

    Press  the 

[

]/[

]

 buttons repeatedly to set the fan speed, in order of 

(High)

(Turbo)

(Medium).

14. Press the 

Set

 button to complete the weekly schedules. 

  

    '_' is displayed for the selected day, and it will be saved in three seconds.

[e.g. when Monday is reserved ( ) ] 

  

    If you need to make additional schedules, start again from the weekly and 

holiday screen. 

15. Press the 

ESC

 button to exit to By-Pass mode.

Weekly Schedule Setting

NASA_Wired Remote Control_MWR-WE10N_EN_IB_DB68-06362A-01.indd   24

2016-08-01   오전 9:18:20

Summary of Contents for MWR-WE11N

Page 1: ...R WE11N Thank you for purchasing this Samsung Product Before operating this unit please read this user manual carefully and retain it for future reference DB68 06362A 01 NASA_Wired Remote Control_MWR WE10N_EN_IB_DB68 06362A 01 indd 1 2016 08 01 오전 9 17 53 ...

Page 2: ...ioner 10 Air Flow 12 IndoorTemperature Checking Function 13 Blade Selection 13 Quiet Sleep Operation 14 Motion Detect Sensor 15 Outdoor Air Intake 15 Humidifying Operation 16 S Plasma Ion 16 Power Consumption Check 17 NASA_Wired Remote Control_MWR WE10N_EN_IB_DB68 06362A 01 indd 2 2016 08 01 오전 9 17 53 ...

Page 3: ...nge Hood Interconnection Control 21 Advanced Instruction Weekly Schedule Setting 22 Setting Holidays during theWeekly Schedule 25 Canceling aWeekly Schedule 26 Initializing aWeekly Schedule 27 Setting Additional User Functions How to Set the Additional User Functions 28 NASA_Wired Remote Control_MWR WE10N_EN_IB_DB68 06362A 01 indd 3 2016 08 01 오전 9 17 53 ...

Page 4: ...product or injury You must connect the product with rated power upon installation Failing to do so may result in problems with the product electric shock or fire Do not install this appliance near a heater inflammable material Do not install this appliance in a humid oily or dusty location in a location exposed to direct sunlight and water rain drops Do not install this appliance in a location whe...

Page 5: ...inspection Neglecting these periodic inspections can result in malfunctions only applicable to GHP model Do not attempt to repair disassemble or modify the appliance yourself This may result in electric shock fire problems with the product or injury FOROPERATION CAUTION Do not allow water to enter the product This may result in fire or electric shock Do not operate the appliance with wet hands Thi...

Page 6: ...ontroller you can turn the air conditioner power on off or set the desired temperature Operation On Off button LED Indicator Green Normal Red Needtobechecked Temperature Setting Button NASA_Wired Remote Control_MWR WE10N_EN_IB_DB68 06362A 01 indd 6 2016 08 01 오전 9 17 54 ...

Page 7: ...Displaysventilator ERV operation DisplaysEnergySavingOperation DisplaysCleanup Displaysventilator ERV fanspeed Common function related information Displays remaining time of the auto stop time ERV delay time Solid Hour unit Blinking Minute unit Displays Demand Response Mode during a Demand Response Event It is applicable to some models for Australia only Displays invalid operation central control ...

Page 8: ...etting button Sets the desired temperature Fan speed button Changes the air conditioner s fan speed Air Flow button Changes the air flow direction Temp button Checks the indoor temperature Blade button Selects a blade for individual control Quiet Sleep button Selects Quiet or Sleep operation for the air conditioner Part Names NASA_Wired Remote Control_MWR WE10N_EN_IB_DB68 06362A 01 indd 8 2016 08 ...

Page 9: ...ed for your Ventilator ERV E Saverbutton Starts Energy Saving Operation Cleanupbutton Selects air purification through the in out load controls After cleaning the filter please press the Filter Reset button The lamp will turn off and it will be turned on again upon the next cleaning period If you press a functional button not supported by the indoor unit then the lamp will turn on If the temperatu...

Page 10: ...ration then the cooling operation is canceled This function produces warm wind so that you can use it in the fall or winter Immediately after starting the heating operation the air conditioner system may stop producing any wind at all for a while to avoid generating any cold wind Defrost indicator Defrost If you start removing frost from the outdoor unit during heating operation the indicator will...

Page 11: ...o You can adjust the desired temperature by 1 C 1 F within a range of 18 C 30 C 65 F 86 F Cool You can adjust the desired temperature by 1 C 1 F within a range of 18 C 30 C 65 F 86 F Dry You can adjust the desired temperature by 1 C 1 F within a range of 18 C 30 C 65 F 86 F Fan You can t change the desired temperature Heat You can adjust the desired temperature by 1 C 1 F within a range of 16 C 30...

Page 12: ...to switch the air flow direction to Spot Mid orWide when a 360 cassette indoor unit is installed together with other types of indoor units the blades of other types of indoor units will be fixed without movement Thus the air flow direction will not change Eventhoughyouchangetheoperationmodeorturnonorofftheremote controller theselectedairflowisnotaffected Fortheducttypeindoorunits whentheAirFlowbut...

Page 13: ... the Room Temp button then the lamp will appear Blade Selection Select only the desired blade to set Air flow function When the air conditioner is on 1 Press the Blade button to select a blade to set the wind direction Each time you press the button it will toggle between The number corresponding to the selected blade will blink 2 PresstheAirFlow buttontoselecttheAirflowdirectionoftheselectedblade...

Page 14: ... will appear Heat Quiet Sleep Quiet Sleep Cancel is repeated If the air conditioner has quiet operation function only Auto Quiet Cancel is repeated Cool Quiet Cancel is repeated Dry Quiet Cancel is repeated Fan Restricted lamp will appear Heat Quiet Cancel is repeated If the air conditioner has sleep operation function only Auto Restricted lamp will appear Cool Sleep Cancel is repeated Dry Restric...

Page 15: ...Away MDS button to use the motion detection function Automatically turn off the power when there is nobody in the room will be displayed and the motion detection function will begin operation Press the Away MDS button one more time Cancel The Away function is applicable only for the duct inverter model with Away function If an indoor unit does not support MDS or AWAY operation but you press the Aw...

Page 16: ...operation and you have pressed the Humidity button then the lamp will be displayed S Plasma Ion Eliminate dangerous airborne contaminants and allergens as well as bacteria and virus When the air conditioner is on press the S Plasma Ion button to select the S Plasma Ion function will be displayed and the S Plasma Ion function is activated Press the S PlasmaIon button one more time Cancel If the ind...

Page 17: ... The temperature is displayed When pressing the kWh button once When pressing the kWh button twice If you don t press any button for 10 seconds the desired temperature will be displayed If the indoor unit is turned off or the kWh is not displayed and you have pressed the kWh button then the lamp will appear NASA_Wired Remote Control_MWR WE10N_EN_IB_DB68 06362A 01 indd 17 2016 08 01 오전 9 18 09 ...

Page 18: ...tilator ERV to the IAQ Heat EX Purifier This can simultaneously operate the Heat ex mode with purifier mode By Pass Purifier This function can clean the air through an intake of fresh external air Intake fresh air will be purified at the same time when this function is used Auto Purifier This function can automatically performVentilator ERV and cleaning at the same time Basic Operation of Ventilat...

Page 19: ...ss the button to change the fan speed Heat EX High Turbo Low Quiet Can t change the fan speed Away Low By Pass High Turbo Low Auto High Turbo Low Purifier High Turbo Auto Low Heat EX Purifier High Turbo Low By Pass Purifier High Turbo Low Auto Purifier High Turbo Low After installing a CO2 sensor in your Ventilator ERV you can select from High Turbo Auto Low Exception Quiet Operation Away Operatio...

Page 20: ... Operation is not available If the ventilator ERV is on or the clean up function is not supported and you have pressed the Clean Up button then the lamp will appear When the ventilator ERV and the air conditioner is connected together This function compares the outdoor and indoor temperatures and then automatically selects Heat EX operation or By Pass operation When the ventilator ERV is installed...

Page 21: ... ERV on or off depending on whether the indoor unit s on or off Even during the external controls you can use your remote controller to control ventilator ERV ENGLISH Range Hood Interconnection Control When the ventilator ERV or MINI AHU indoor operates in another mode it will be indicated if the Range Hood interconnection is achieved If you change operation during Range Hood interconnection the n...

Page 22: ... select a device setting from among Air Conditioner Ventilator ERV Air Conditioner or Ventilator ERV You can only select a Schedule Device that is connected 5 After pressing the button select AM PM Press the buttons to select AM or PM for the time You can select many days for multiple schedules In this case you should directly move to Schedule Device selection without selecting a schedule number I...

Page 23: ...u can only use this for air conditioner on operation scheduling Press the buttons repeatedly to select from Auto Cool Dry Fan Heat operation Depending on the option setting automatic or heating operation sometimes cannot be selected When you install the Wired Remote Controller the setting is available 10 Press the button and select the desired temperature You can only use this for air conditioner ...

Page 24: ...ou can only use this for Heat Ex on operation scheduling Press the button select the ERV related operation mode Heat EX Quiet Away Bypass Auto Purifier Heat Ex Purifier By Pass Purifier Auto Purifier 13 After pressing the button select a fan speed for ventilator ERV You can only use this for Heat Ex on operation scheduling Press the buttons repeatedly to set the fan speed in order of High Turbo Me...

Page 25: ...hedule You can select the holidays Sun Sat by pressing button 3 Press Set button to complete the holiday of weekly schedule setting 4 Press the ESC button to exit to By Pass mode You can select several days for multiple settings If you want to cancel your holiday of weekly schedule while you are setting them press the ESC button You can set the holidays only with the dates with weekly indicator _ ...

Page 26: ...n to select a scheduled day 3 After pressing the button select a schedule number to cancel Press the button to select a schedule number 1 6 4 Press Delete button to cancel the weekly schedule setting you made 5 Press Set button to save the cancellation of your weekly schedule 6 Press the ESC button to exit to general mode NASA_Wired Remote Control_MWR WE10N_EN_IB_DB68 06362A 01 indd 26 2016 08 01 ...

Page 27: ...r 1 Press the Delete button for five seconds All the weekly schedule settings will be erased You can t restore your old settings after deleting the weekly schedule by pressing the Delete button so be careful when you use this function NASA_Wired Remote Control_MWR WE10N_EN_IB_DB68 06362A 01 indd 27 2016 08 01 오전 9 18 23 ...

Page 28: ...he data setting screen Once you have entered the setting screen the current setting will be displayed Refer to the chart for data setting Using the buttons change the settings and press the button to move to the next setting Press the Set button to save the setting and exit to the sub menu setting screen Press the ESC button to exit to general mode Mainmenu Sub menu While setting the data you can ...

Page 29: ...eekly 1 Daily 2 Summer time use Weekly Start Month th Sunday 1 2 4 03 F 1 12th month 1 4 F last week th week 3 Summer time use Weekly End Month th Sunday 1 2 4 10 F 1 12 month 1 4 F last week th week 4 Summer time use Daily Start Month th Sunday 1 2 3 4 03 22 Jan Dec 1 31st day Month date 5 Summer time use Daily End Month th Sunday 1 2 3 4 09 22 Jan Dec 1 31st day Month date 6 Backlight Time Setti...

Page 30: ...ou can modify the year month date setting 3 Press the button to select the Year Press the buttons to select the year 00 99 4 Press the button to select the Month Press the buttons to select month 01 12 5 Press the button to select the Date Press the buttons to select date 01 31 6 Press the Set button to complete your setting of Year Month Date The setting changes will be applied and you can exit t...

Page 31: ... between AM and PM 10 Press the button to select the Hour Press the buttons to select the hour 01 12 11 Press the button to select the Minute Press the buttons to select minute 00 59 12 By pressing the Set button you can complete modifying the setting for the current time The setting changes are applied and you can exit to general mode 13 Press the ESC button to exit to general mode NASA_Wired Rem...

Page 32: ...NASA_Wired Remote Control_MWR WE10N_EN_IB_DB68 06362A 01 indd 32 2016 08 01 오전 9 18 27 ...