background image

ENGLISH-2

Contents

PREPARATION

Safety precautions   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3
Checking before using the product     .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  6

BASIC OPERATION

Using the remote controller   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  7
Basic operation     .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  10

TIMER

Setting the On/Off timer   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  13
Setting the good’sleep mode     .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  15

OPTIONS

Using the Turbo function   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  17
Using the Purity function     .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  18
Using the Quiet function   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  19

SETTINGS

Selecting an indoor unit     .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  20
Selecting a blade     .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  20

OTHERS

Appendix   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  21

System_WRC_IB_DB68-05423A-00_EN.indd   2

2017-02-13   오후 5:04:33

Summary of Contents for MR-EH01

Page 1: ...Air conditioner user manual imagine the possibilities ThankyouforpurchasingthisSamsungproduct This manual is made with 100 recycled paper EN NO SV DA FI ET DE RU DB68 05423A 00 System_WRC_IB_DB68 05423A 00_EN indd 3 2017 02 13 오후 5 04 32 ...

Page 2: ...ntroller 7 Basic operation 10 TIMER Setting the On Off timer 13 Setting the good sleep mode 15 OPTIONS Using theTurbo function 17 Using the Purity function 18 Using the Quiet function 19 SETTINGS Selecting an indoor unit 20 Selecting a blade 20 OTHERS Appendix 21 System_WRC_IB_DB68 05423A 00_EN indd 2 2017 02 13 오후 5 04 33 ...

Page 3: ...ounded to prevent electric shock Unplug the appliance Do NOT disassemble FOR INSTALLATION WARNING The installation of this product must be performed by a qualified technician X X Failure to do so may result in electric shock fire product malfuction explosion or injury Do not install this product near a heater or inflammable material Do not install this product in a humid oily or dusty location in ...

Page 4: ...duct damage FOR OPERATION WARNING If the product generates a strange noise a burning smell or smoke unplug the product immediately and contact your nearest service center X X Otherwise electric shock or fire may occur Do not attempt to repair disassemble or modify the product yourself X X Otherwise electric shock fire product malfuction or injury may occur System_WRC_IB_DB68 05423A 00_EN indd 4 20...

Page 5: ...oduct malfunction Do not give a strong impact to the product and do not disassemble the product Do not use this product for other purposes X X This product is designed to be used only for a system air conditioner Do not press the buttons with any sharp objects X X Otherwise electric shock or part damage may occur Do not clean the product by spraying water directly onto it Do not use benzene thinne...

Page 6: ...roller holder Where there is no interference to the remote controller signal Not exposed to direct sunlight or heat source More than 1 m away from a television or stereo system NOTE 1 Mark the spots with a pencil where you will install the remote controller holder 2 Drill the marked holes 2EA for screws on the wall 3 Install the remote controller holder on the wall by using the screws System_WRC_I...

Page 7: ...r on or off Temperature Adjusts the temperature Options Selects options during operation Direction Moves to select and set an option Fan speed Adjusts the fan speed Air flow direction Up and down Adusts the air flow direction up and down Not applicable to Duct type models SET Selects or cancels an option Settings Selects settings Timer Sets timer option In case you wish to cancel the options or se...

Page 8: ...rning off the remote controller are cancelled However the fan direction does not change NOTE Battery changing time When the battery is exhausted will be displayed on the remote controller display When the icon appears change the batteries The remote controller requires two 1 5V AAA type batteries Storing the remote controller When you do not use the remote controller for a long time remove the bat...

Page 9: ...y clean the filter and press the Settings or Settings Filter Reset blinking SET button Beep off To silence the beep sound press the Settings or Settings Beep blinking SET button If you press the Settings or Settings Beep blinking SET button again the beep sound will ring again NOTE Correctdisposalofbatteriesinthisproduct Applicableincountrieswithseparatecollectionsystems This marking on the batter...

Page 10: ...ence immediately to avoid generating a cold breeze f f During the Heat mode defrost operation may be performed to remove the frost formed on the outdoor unit When the frost is removed by the defrost operation in Heat mode steam is generated from the outdoor unit f f If you stop operating the air conditioner after heating operation the fan will operate for some time to cool the indoor unit f f When...

Page 11: ...y 1 C within the range of 18 C 30 C Cool Temperature can be adjusted by 1 C within the range of 18 C 30 C Dry Temperature can be adjusted by 1 C within the range of 18 C 30 C Fan Temperature cannot be adjusted Heat Temperature can be adjusted by 1 C within the range of 8 C 30 C Selecting the fan speed Press the button to adjust the fan speed Auto Auto Cool Auto Low Med High Dry Auto Fan Low Med Hi...

Page 12: ...ion up and down or left and right while the air conditioner is turned on Remote controller display f f When the blade reaches the desired position press the or button one more time to set the air flow direction The up down and left right tilting of the blade will stop Duct type model cannot adjust air flow direction up and down System_WRC_IB_DB68 05423A 00_EN indd 12 2017 02 13 오후 5 04 35 ...

Page 13: ...ntroller display On timer setting will be cancelled if you don t press the SET button within 10 seconds after setting the time Therefore check for the On indicator on the remote controller display Cancel f f Press the Timer button select On press the or button set the timer to press the SET button Additional options available in On timer Select the mode from Auto Cool Dry Fan and Heat You can adju...

Page 14: ...utton set the timer to press the SET button Only the latest setting timer will be applied between the OffTimer and good sleep off timer functions NOTE Combining On timer and Off timer When the air conditioner is turned off When the air conditioner is turned on When set time on On timer is shorter than Off timer e g On timer 3 hours Off timer 5 hours The air conditioner will be turned on after 3 ho...

Page 15: ...minimum 30 minutes to maximum 12 hours Default time setting for the good sleep mode is 8 hours 3 Press the SET button to complete the good sleep mode setting indicator and the set time of the good sleep mode will be displayed on the remote controller display good sleep mode will be cancelled if you don t press the SET button within 10 seconds after setting the time Therefore check for the indicato...

Page 16: ...ween 25 C 27 C and 26 C is the most ideal temperature If the set temperature is too low you may feel cold during sleep or catch a cold Optimal operation hour of good sleep mode is 8 hours Therefore if the time is set too short or long you may not feel as comfortable as you would expect If the good sleep mode is set over 5 hours Wake up stage will begin when 1 hour is remaining in the operation tim...

Page 17: ...d on the remote controller display andTurbo function will operate for 30 minutes Cancel f f Press the Options button press the or Options button to make the Turbo indicator blink and press the SET button Turbo function is only available in Cool Heat mode If theTurbo function is selected while Quiet function is on the Quiet function will be cancelled Air flow direction can be adjusted with every di...

Page 18: ...re If the purity function is selected additionally in fan mode the temperature cannot be adjusted When the air conditioner and the purity function are turned on simultaneously and you press the Power button both air conditioner and purity function will stop operation You can still use the purity function when the On timer is set with the air conditioner is turned off There will not be much differe...

Page 19: ...and Quiet function will begin Cancel f f Press the Optionsbutton press the or Options button to make the Quiet indicator blink and press the SET button Additional options available in Quiet function In Cool mode Temperature can be adjusted by 1 C within the range of 18 C 30 C In Heat mode Temperature can be adjusted by 1 C within the range of 8 C 30 C Fan speed is set to Auto Air flow direction ca...

Page 20: ...time Selecting a blade You can select and operate individual blades out of 4 blades When the air conditioner is turned on Remote controller display 1 Press the button Blade 1234 will be displayed 2 Press the Settings button 3 Press the or Settings button until Blade indicator starts to blink 4 Press the SET button to select the blade you want to operate You can select the individual blades in orde...

Page 21: ...ed Not supported good sleep Not supported Not supported Not supported Turbo Not supported Not supported Not supported Purity Supported Supported Not supported Individual blade control Supported Supported Not supported Multi channel Indoor unit selection Supported Supported Supported Beep Supported Supported Not supported Forced trial operation Not supported Not supported Not supported Refrigerant ...

Page 22: ...System_WRC_IB_DB68 05423A 00_EN indd 2 2017 02 13 오후 5 04 32 ...

Reviews: