E-
17
ENGLISH
Troubleshooting
����
����
����
��������������
1 2
3
45
67
8
9 0
����������
12
34
5
6 7
8 9
0
Abnormal conditions
LED lamp display
Remarks
White
Power reset
X
X
X
X
Error of temperature sensor
in the indoor unit (Open/Short)
X
X
X
X
Error of heat exchanger sensor
in the indoor unit
X
X
X
Indoor fan motor is non-operative
Indoor fan motor is operating slowly
Indoor fan motor operates at an excessive
speed
X
X
X
X
Indoor motor fan error
Error of the outdoor temperature sensor
Error of the condensor temperature sensor
Error of the discharge temperature sensor
X
X
X
1. No comunication between indoor and outdoor
unit for 2 minutes
2. Error on the communication received from
outdoor unit
3. Outdoor unit tracking time out(3 minutes)
4. Number of Installation doesn't match after
tracking
X
X
X
1. Indoor unit error
(Display is unrelated with
operation)
2. Outdoor unit error
(Display is unrelated with
operation)
Simultaneous cooling/heating operation
error (Multi mode only)
X
X
X
If you turn off the air conditioner when the LED is flickering, the LED is also turned off.
On Flickering X Off
Detection of errors
If an error occurs during the operation, one or more LED flickers and the operation is stopped except the LED.
If you re-operate the air conditioner, it operates normally at first, then detect an error again.
Display Error mode
FJM CONSOLE_IM_29317A_E_12.05.08.indd 17
2008-12-5 15:56:30