background image

English  3

Gener

al inf

ormation

General information

IMPORTANT SAFETY INSTRUCTIONS

This product requires a three-prong grounded outlet. The installer must perform a 
ground continuity check on the power outlet box before beginning the installation 
to ensure that the outlet box is properly grounded. If not properly grounded, or 
if the outlet box does not meet electrical requirements noted (under ELECTRICAL 
REQUIREMENTS), a qualified electrician should be employed to correct any 
deficiencies.

CAUTION

For personal safety, remove the house fuse or open the 
circuit breaker before beginning the installation to avoid 
severe or fatal shock injury.

CAUTION

• 

For personal safety, the mounting surface must be capable of supporting the 
cabinet load in addition to the added weight of this 69 pound product, plus 
additional oven loads of up to 50 pounds or a total weight of 119 pounds.

• 

For personal safety, do not install this product in cabinetry configured as an 
island or a peninsula. The microwave oven must be mounted to BOTH a top 
cabinet AND a wall.

NOTE

For easier installation and personal safety, we recommend that two people install 
this product.

IMPORTANT – PLEASE READ CAREFULLY. FOR PERSONAL SAFETY, 
THIS APPLIANCE MUST BE PROPERLY GROUNDED TO AVOID SEVERE 
OR FATAL SHOCK.

Insure proper 
ground exists 
before use.

The power cord of this appliance is equipped with 
a three-prong (grounding) plug which mates with a 
standard three-prong (grounding) wall receptacle to 
minimize the possibility of electric shock hazard from 
this appliance.

You should have the wall receptacle and circuit checked by a qualified electrician 
to make sure the receptacle is properly grounded.
If you have a standard two-prong wall receptacle, it is very important to have 
it replaced with a properly grounded three-prong wall receptacle, installed by a 
qualified electrician.

DO NOT, UNDER ANY CIRCUMSTANCES, CUT, DEFORM OR REMOVE ANY OF THE 
PRONGS FROM THE POWER CORD. DO NOT USE WITH AN EXTENSION CORD.

ELECTRICAL REQUIREMENTS

Product rating is 120 volts AC, 60 Hertz, 14.5 amps and 1.7 kilowatts. This product 
must be connected to a supply circuit of the proper voltage and frequency. Wire 
size must conform to the requirements of the National Electrical Code or the 
prevailing local code for this kilowatt rating. The power supply cord and plug 
should be brought to a separate branch circuit single grounded outlet of at least 
15 A and max of 20 A. The outlet box should be located in the cabinet above 
the microwave oven. The outlet box and supply circuit should be installed by a 
qualified electrician and conform to the National Electrical Code or the prevailing 
local code. 

Install_ME11A7510DG_AC_DE68-04709B-00_EN+CFR.indb   3

Install_ME11A7510DG_AC_DE68-04709B-00_EN+CFR.indb   3

2021-06-16   �� 11:00:48

2021-06-16   �� 11:00:48

Summary of Contents for ME11A7510 Series

Page 1: ...Microwave Oven Installation manual ME11A7510 ME11A7710 Install_ME11A7510DG_AC_DE68 04709B 00_EN CFR indb 1 Install_ME11A7510DG_AC_DE68 04709B 00_EN CFR indb 1 2021 06 16 11 00 48 2021 06 16 11 00 48 ...

Page 2: ...TIONS COMPLETELY AND CAREFULLY Important Save these instructions for local inspector s use Observe all governing codes and ordinances Important note to the installer Be sure to leave these instructions with the Consumer Important note to the consumer Keep these instructions with your user manual for future reference Skill level Installation of this appliance requires basic mechanical and electrica...

Page 3: ...ists before use The power cord of this appliance is equipped with a three prong grounding plug which mates with a standard three prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance You should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded If you have a standard two prong w...

Page 4: ...these next two pages only if you plan to vent your exhaust to the outside If you plan to recirculate the air back into the room proceed to page 12 OUTSIDE TOP EXHAUST EXAMPLE ONLY The following chart contains an example of one possible ductwork installation DUCT PIECES EQUIVALENT LENGTH x NUMBER USED EQUIVALENT LENGTH Roof Cap 24 ft x 1 24 ft 12 Ft Straight Duct 6 Round 12 ft x 1 12 ft Rectangular...

Page 5: ...nd with as few elbows as possible This ensures clear venting of exhaust and helps prevent blockages Also make sure dampers swing freely and nothing is blocking the ducts Exhaust connection The hood exhaust has been designed to mate with a standard 3 x 10 rectangular duct If a round duct is required a rectangular to round transition adaptor must be used Do not use less than a 6 diameter duct Maximu...

Page 6: ...the unit is damaged by the customer repair or replacement is the responsibility of the customer If the unit is damaged by the installer if other than the customer repair or replacement must be made by arrangement between the customer and installer PARTS INCLUDED HARDWARE PACKET PART QUANTITY Template Wood Screws 1 Template INSTALLATION TRUCTIONS Toggle Bolts and wing nuts 2 Self aligning Machine S...

Page 7: ...ovided are the minimum required for mounting the microwave oven Local codes and the practical use of the range will likely require you to provide more than the 13 5 shown between the range and the bottom of the microwave TOOLS YOU WILL NEED 1 and 2 Phillips screwdriver Pencil Ruler or tape measure and straight edge Carpenter square optional Tin snips for cutting damper if required Scissors to cut ...

Page 8: ... OF PRODUCT 46 11 16 1185 9mm With Plate mounting 29 7 8 758 8mm 10 11 16 272 0mm 19 3 16 486 7mm With Plate mounting Install_ME11A7510DG_AC_DE68 04709B 00_EN CFR indb 8 Install_ME11A7510DG_AC_DE68 04709B 00_EN CFR indb 8 2021 06 16 11 00 50 2021 06 16 11 00 50 ...

Page 9: ...ate A Removing the microwave oven from the carton Removing the mounting plate Carton Styrofoam Mounting Plate Screws Screws 1 Remove the installation instructions Exhaust Adaptor filters glass tray and the small hardware bag Do not remove the Styrofoam protecting the front of the oven 2 Fold back all 4 carton flaps fully against carton sides Then carefully roll the oven and carton over onto the to...

Page 10: ... below the cabinet to mark how far the inside of the front overhang descends below the cabinet Tape the Rear Wall Template onto the wall so that the top of the template touches the bottom of the horizontal line and the centerline on the template lines up with the vertical line C L 24 1 5 Plate position beneath a framed recessed cabinet bottom Draw a vertical line on the wall at the center of the 3...

Page 11: ...R WILL DISCHARGE INTO HOUSE STRUCTURE Locate and mark holes to align with holes in the mounting plate IMPORTANT LOCATE AT LEAST ONE STUD ON EITHER SIDE OF THE CENTERLINE MARK THE LOCATION FOR 2 ADDITIONAL EVENLY SPACED TOGGLE BOLTS IN THE MOUNTING PLATE AREA IT IS RECOMMENDED TO INSTALL BOLTS IN A B AND C HOLES THE LOCATION MAY BE SUBJECT TO CHANGE ACCORDING TO CIRCUMSTANCES BUT IT IS RECOMMENDABL...

Page 12: ...s shipped assembled and attached to the filler upper Select the type of ventilation required for your installation and proceed to that section A Outside top exhaust vertical duct A1 ADAPTING THE COVER PANEL FOR THE EXHAUST ADAPTOR Cover Panel Back Panel 1 Remove 1 screw from Cover Panel and take off Cover Panel 2 Remove 1 screw from Back Panel 3 Assemble the Cover Panel as sliding from top to bott...

Page 13: ... Cover Panel is assembled properly Top assembly A2 INSTALLATION DAMPER Damper 1 Remove the tape securing the Damper 2 Assemble the Damper as sliding from back to front until stopped NOTE Make sure Dampers swing freely House Duct House Duct NOTE You must attach the House Duct to the Exhaust Adaptor after installation is complete You must seal Exhaust Duct joints using Duct Tape Install_ME11A7510DG_...

Page 14: ...nt holes NOTE The Exhaust Adaptor with the Damper is not needed for recirculating type You may want to save them for possible future use You must check bracket picture according to ventilation type at page 12 C Outside back exhaust horizontal duct C1 Adapting the COVER PANEL for outside back exhaust 1 Make sure the Cover Panel is assembled properly Top assembly Install_ME11A7510DG_AC_DE68 04709B 0...

Page 15: ...the dimensions 117 16 290 75mm 631 64 164 5mm DE68 04708A 00 3 1 2 88 7mm 1 27 32 47mm 9 1 4 235mm 1 15 32 37 3mm 26 3 16 664 8mm 1 27 32 47mm 3 Remove the tape securing the Damper 4 Assemble the Damper as sliding from top to bottom until stopped NOTE Make sure Dampers swing freely Step 3 Installation INSTALLATION OVERVIEW F CUT OUT FOR HORIZONTAL OUTSIDE EXHAUSE REAR WALL TEMPLATE A Prepare the R...

Page 16: ...LATE Tape it underneath the top cabinet Drill the holes following the instructions on the TOP CABINET TEMPLATE CAUTION Wear safety goggles when drilling holes in the cabinet bottom A Prepare the rear wall for outside back exhaust You need to cut an opening in the rear wall for outside exhaust C L Read the instructions for outside back exhaust on the REAR WALL TEMPLATE Tape the REAR WALL TEMPLATE t...

Page 17: ... Self Aligning Screw NOTE The self aligning screw can be installed up to 1 15 16 49mm D Mount the microwave oven FOR EASIER INSTALLATION AND PERSONAL SAFETY WE RECOMMEND THAT TWO PEOPLE INSTALL THIS MICROWAVE OVEN IMPORTANT Do not grip or use the handle during installation NOTE If your cabinet is metal use the nylon grommet in the power cord hole to prevent the cord from being cut Filler blocks ar...

Page 18: ...2 self aligning screws through the cabinet bottom shelf and filler block into the outer top cabinet of the unit Continue to support the unit until both screws are inserted and engaged at least two full turns then fully tighten all screws until the unit is secure E Installing the charcoal filters and Grease Filters E1 Charcoal Filter assembly method 1 Insert the Charcoal Filter from the back 2 Rais...

Page 19: ...move all packing material from the microwave oven 3 Install the turntable and ring in the cavity 4 Replace the house fuse or turn the breaker back on Insure proper ground exists before use 5 Plug the power cord into a dedicated 15 amp electrical outlet 6 Read the Owner s Manual Install_ME11A7510DG_AC_DE68 04709B 00_EN CFR indb 19 Install_ME11A7510DG_AC_DE68 04709B 00_EN CFR indb 19 2021 06 16 11 0...

Page 20: ...1 800 SAMSUNG 726 7864 www samsung com us support CANADA 1 800 SAMSUNG 726 7864 www samsung com ca support English www samsung com ca_fr support French DE68 04709B 00 Scan the QR code or visit www samsung com spsn to view our helpful How to Videos and Live Shows Requires reader to be installed on your smartphone Install_ME11A7510DG_AC_DE68 04709B 00_EN CFR indb 20 Install_ME11A7510DG_AC_DE68 04709...

Page 21: ...our à micro ondes Manuel d installation ME11A7510 ME11A7710 Install_ME11A7510DG_AC_DE68 04709B 00_EN CFR indb 1 Install_ME11A7510DG_AC_DE68 04709B 00_EN CFR indb 1 2021 06 16 11 00 54 2021 06 16 11 00 54 ...

Page 22: ...es instructions d installation afin que la personne chargée du contrôle local puisse s y reporter Conservez précieusement ce manuel en vue du passage éventuel d un technicien en cas de réparation Remarque importante destinée à l installateur Assurez vous de laisser ces instructions à l utilisateur Remarque importante destinée à l utilisateur Conservez ces instructions avec votre manuel d utilisati...

Page 23: ...A TERRE AFIN D ÉVITER TOUT RISQUED ÉLECTROCUTION Assurez vous que le four est correctement mis à la terre avant de l utiliser Le cordon d alimentation de cet appareil est équipé d une prise tripolaire mise à la terre correspondant à la prise murale tripolaire standard mise à la terre afin de réduire le risque d électrocution Faites vérifier la prise murale et le circuit par un électricien qualifié...

Page 24: ... pages ne vous concernent que si vous souhaitez utiliser un système d évacuation de l air Si vous souhaitez que la circulation de l air se fasse en circuit fermé passez à la page 12 SYSTÈME D ÉVACUATION PAR LE HAUT EXEMPLE UNIQUEMENT Le tableau suivant contient un type d installation de conduits possible COMPOSANTS DE L ÉVACUATION LONGUEUR ÉQUIVALENTE x NOMBRE UTILISÉ LONGUEUR ÉQUIVALENTE Chaperon...

Page 25: ... moins de coudes possible Cela garantit une ventilation dégagée de l échappement et aide à prévenir les blocages Assurez vous également que les registres oscillent librement et que rien ne bloque les conduits Raccord d échappement L évacuation de la hotte a été conçue pour s accoupler avec un conduit rectangulaire standard de 3 x 10 po Si un conduit rond est requis un adaptateur de transition rect...

Page 26: ...ou remplacé Si l appareil est endommagé par l utilisateur sa réparation ou son remplacement lui incombe Si l appareil est endommagé par l installateur autre que l utilisateur un accord devra être trouvé entre l utilisateur et l installateur en vue d une réparation ou d un remplacement PIÈCES INCLUSES AVEC LE PRODUIT MATÉRIEL PIÈCE QUANTITÉ Template Vis à bois 1 Template INSTALLATION TRUCTIONS Boul...

Page 27: ...2 po Les dimensions indiquées sont celles minimales nécessaires pour le montage du four micro ondes Les codes locaux et l utilisation pratique de la cuisinière peuvent nécessiter un espace supérieur aux 13 5 po indiqués entre la cuisinière et la partie inférieure du four micro ondes OUTILS NÉCESSAIRES Tournevis cruciforme n 1 et n 2 Crayon Règle ou mètre à ruban et règle plate Équerre de charpenti...

Page 28: ...DUIT 46 11 16 po 1185 9 mm avec plaque de support 29 7 8 po 758 8 mm 10 11 16 po 272 0 mm 19 3 16 po 486 7 mm avec plaque de support Install_ME11A7510DG_AC_DE68 04709B 00_EN CFR indb 8 Install_ME11A7510DG_AC_DE68 04709B 00_EN CFR indb 8 2021 06 16 11 00 57 2021 06 16 11 00 57 ...

Page 29: ...étape Étape 1 Emplacement de la plaque de fixation A Retrait du four micro ondes du carton retrait de la plaque de fixation Carton Polystyrène Plaque de fixation Vis Vis 1 Retirez les consignes d installation l adaptateur du système d évacuation les filtres le plateau en verre et le sachet contenant le matériel Ne retirez pas la mousse de polystyrène protégeant l avant du four 2 Pliez les 4 rabats...

Page 30: ... le meuble afin de marquer la distance dont la partie intérieure du débord frontal descend sous le meuble Fixez le gabarit du fond au mur afin que la partie supérieure du gabarit touche le bas de la ligne horizontale et que le trait central du gabarit soit aligné avec la ligne verticale C L 24 1 5 po Position de la plaque sous un fond d armoire encastré encadré Tracez un trait vertical sur le mur ...

Page 31: ...ARIT POUR MUR ARRIÈRE Ce modèle de paroi arrière permet de placer la plaque de fixation inférieure et de localiser la sortie d air horizontale 1 Utilisez un niveau pour vous assurer que le modèle est correctement positionné 2 Localisez et marquez d un repère au moins un goujon à droite ou à gauche de l axe médian REMARQUE Utilisez au moins une vis à bois et fixez la solidement dans un goujon afin ...

Page 32: ...teur du système d évacuation est livré assemblé et fixé à la cale supérieure Sélectionnez le système de ventilation adapté à votre installation et reportez vous à la section correspondante A Système d évacuation par le haut conduit vertical A1 ADAPTATION DU PANNEAU DE PROTECTION POUR L ADAPTATEUR D ÉCHAPPEMENT Panneau de couverture Panneau arrière 1 Retirez 1 vis du panneau de couverture et retire...

Page 33: ...u de couverture est assemblé correctement Assemblage supérieur A2 MONTAGE DU REGISTRE Registre 1 Retirez le ruban fixant le registre 2 Assemblez le registre en le glissant de l arrière vers l avant jusqu à l arrêt REMARQUE Assurez vous que les registres oscillent librement House Duct Conduit de maison REMARQUE Vous devez fixer le conduit de l habitation à l adaptateur du système d évacuation après...

Page 34: ...tateur d échappement avec le registre n est pas nécessaire pour le type à recirculation Vous pouvez toutefois les conserver en vue d une utilisation ultérieure éventuelle Vous devez vérifier l image du support en fonction du type de ventilation à la page 12 C Système d évacuation par l arrière conduit horizontal C1 Adaptation du PANNEAU DE COUVERTURE pour échappement arrière extérieur 1 Assurez vo...

Page 35: ...les vis dans les trous D et E vérifiez les dimensions 631 64 164 5mm Vissez la longueur d exposition du fond du placard à l extrémité du boulon sans l option de Supporter 28 32 126 32 46mm 22mm Vissez la longueur d exposition du fond du placard à l extrémité du boulon lorsque vous utilisez l option Supporter 28 32 130 32 49mm 22mm DE68 04708B 00 Découpez d abord ce trou avant de découper l ouvertu...

Page 36: ...lez le sous le plancher du meuble haut Percez les trous en respectant les instructions figurant sur le GABARIT DU MEUBLE HAUT ATTENTION portez des lunettes de sécurité pendant cette dernière opération A Préparez la paroi arrière pour l échappement arrière extérieur Vous devez pratiquer une ouverture dans le mur du fond pour installer le système d évacuation C L Lisez les instructions relatives au ...

Page 37: ...irez le supporter de la vis d autoalignement REMARQUE La vis autocentreuse peut être installée jusqu à une profondeur de 1 15 16 po 49 mm D Montage du four micro ondes POUR PLUS DE FACILITÉ ET DE SÉCURITÉ LORS DE L INSTALLATION DE L APPAREIL DEUX PERSONNES SONT NÉCESSAIRES IMPORTANT évitez de saisir ou d accrocher la poignée du four pendant l installation REMARQUE si votre meuble est en métal plac...

Page 38: ... four micro ondes sur le meuble haut 5 Insérez 2 vis autocentreuses à travers le fond du meuble et des cales dans les trous extérieurs du meuble haut de l unité Continuez le soutien l unité jusqu à ce que les deux vis soient insérées et engagées d au moins deux tours complets puis serrez complètement toutes les vis jusqu à ce que l unité soit sécurisée E Installation des filtres à charbon et des f...

Page 39: ...tions 2 Retirez tout élément d emballage du four micro ondes 3 Installez le plateau tournant et la bague dans la cavité 4 Remplacez le fusible ou remettez le disjoncteur sous tension Assurez vous que le four est correctement mis à la terre avant de l utiliser 5 Branchez le cordon d alimentation sur une prise dédiée de 15 A 6 Lisez le manuel d utilisation Install_ME11A7510DG_AC_DE68 04709B 00_EN CF...

Page 40: ...e l appareil corriger une installation non correcte ou exécuter des travaux de nettoyage ou d entretien réguliers UNE QUESTION UN COMMENTAIRE PAYS N DE TÉLÉPHONE SITE INTERNET U S A Consumer Electronics 1 800 SAMSUNG 726 7864 www samsung com us support CANADA 1 800 SAMSUNG 726 7864 www samsung com ca support English www samsung com ca_fr support French DE68 04709B 00 Install_ME11A7510DG_AC_DE68 04...