Installing the product

Installing the Multi Tenant Function Controller box

f

f

The size of the Multi Tenant Function Controller box should be more than 210 mm(W) x 130 mm(H) x 100 mm(D).

f

f

Fix the plate (PD, MD) to the Multi Tenant Function Controller box and assemble the holders (for fixing PBA) to install the 
Multi Tenant Function Controller. 
- Make 4 holes to fix PBA on the plate.

HOLE SIZE : 5 mm diameter

W

D

H

65 mm

85 mm

4 PBA holder 

holes

100 mm

Plate

75 mm

25 mm or

 

mor

e

25 mm or

 

mor

e

110 mm

50 mm 

or more

50 mm 

or more

MTFC 

HOLDER 4EA

Close the gap completely to prevent 
rodents or water from entering.

The installation location of Multi Tenant Function Controller box

f

f

For ceiling type indoor unit, the distance between an indoor unit and the Multi Tenant Function Controller box should be 
within 3 m.

When the Multi Tenant Function Controller is installed, the Multi Tenant Function Controller box should be fixed. 

f

f

For wall-mounted indoor unit, the Multi Tenant Function Controller box should be concealed inside the wall and the 
distance between an indoor unit and Multi Tenant Function Controller box should be within 3 m.

For ceiling type: 1 WAY CASSETTE, 4 WAY CASSETTE and DUCT

Within 3 m

Indoor Unit

Multi Tenant Function 
Controller box

For wall-mounted type

Within 

3 m

Indoor 

Unit

Wall

Multi Tenant Function 
Controller box

보조전원 모듈_MCM-C21FR_03929A-06.indd   6

2016-04-21   오후 3:30:10

Summary of Contents for MCM-C210

Page 1: ...ner installation manual imagine the possibilities Thank you for purchasing this Samsung product Multi Tenant Function controller MCM C210 MCM C210N 보조전원 모듈_MCM C210_IM_EN FR_03929A 06 indd 11 2016 04 21 오후 3 30 11 ...

Page 2: ...ATION CAUTION When connecting a wire do not tighten it too much f f Failure to do so may result in breakage of the wire Make sure the MultiTenant Function Controller installation doesn t cause interference with other electrical appliances particularly in a hospital etc f f Failure to do so may result in abnormal operation Do not install the product in an area where combustible gas leaks or possibl...

Page 3: ...Assurez vous que le contrôleur de fonctions multi tenant ne provoque pas d interférence avec d autres appareils électriques en particulier dans un hôpital etc f f Le non respect de cette consigne risque de provoquer un dysfonctionnement N installez pas l appareil dans un emplacement présentant des fuites de gaz combustible ou s il existe un risque potentiel de fuite de gaz f f Le non respect de ce...

Page 4: ...on of the Multi Tenant Function Controller and wiring work must be done in advance so that they can be connected to each other About protection box Protection box for the MultiTenant Function Controller must be purchased separately Installing the MultiTenant Function Controller within an Ingress Protection IP box or a box made of metal metrial is recommended Accessories Name MultiTenant Function C...

Page 5: ...Download Circuit Breaker Fuse Not provided When installing a the AC 24 V transformer use a box or metal material with the same or higher level of fire retardant as the IP box You should close the gap around the place where wires are input so that any rodents or water cannot come into the box and then remove all the sharp surfaces AC 24V needs to be purchased at a local shop You should purchase a r...

Page 6: ... entering The installation location of MultiTenant Function Controller box f f For ceiling type indoor unit the distance between an indoor unit and the MultiTenant Function Controller box should be within 3 m When the MultiTenant Function Controller is installed the MultiTenant Function Controller box should be fixed f f For wall mounted indoor unit the MultiTenant Function Controller box should b...

Page 7: ... cable is correctly connected IfthegreenLEDoftheMultiTenantFunctionControllerdoesnotturnon checkifthepolarityoftheV1andV2arecorrect f f For the products with noV1 andV2 terminal block on the indoor units such as RAC 2WAY connect the 1 wire RED of the 4P connector wire connected to the communication SUB PCB to theV1 V2 connection is not required N L AC power for an indoor unit INDOOR POWER F1 F2 V1...

Page 8: ... option f f To use the MultiTenant Function Controller installation option must be changed f f SEG2 of the installation option on installed indoor units must be set to 5 and SEG11 must be set to 2 SEG11 0 Disable MultiTenant Function Controller 2 Enable MultiTenant Function Controller For detail information on the method of setting the installation option please refer to the indoor unit installati...

Page 9: ...rUnit 1 When installing one transformer with multiple MTFCs MultiTenant Function Controller AC220V AC220V AC24V N 1A Transformer MTFC MTFC N Numberof MTFC DC12V DC5V DC12V DC5V Comm IndoorUnit 2 IndoorUnit 1 f f When one transformer is installed with multiple MTFCs current capacity setting should be 1 A x number of MTFC 보조전원 모듈_MCM C210_IM_EN FR_03929A 06 indd 9 2016 04 21 오후 3 30 11 ...

Page 10: ...보조전원 모듈_MCM C210_IM_EN FR_03929A 06 indd 10 2016 04 21 오후 3 30 11 ...

Reviews: