4-16
4. Troubleshooting
When replacing the panel
After replacing the panel, select the Panel Ch. No. item and press the MENU key for five seconds.
The Panel Ch. No. will then increment by one and the panel’s time information will be set to 0.
At the same time, the panel cycle will be set to 0.
Service Mode features
Auto Auto : On / Off
-
PixelShift : On / Off
-
Country : English / Korean / Chinese / Japanese
-
HDCP HP-DVI : On / Off (Hotplug function On/ Off for DVI)
-
HDCP HP-HDMI : On / Off (Hotplug function On/ Off for DVI)
-
HotPlug Time : 5~50 (Default 9 : 0.9sec)
-
=> This feature lowers the level of voltage to that of Hotplug Time during communication for recognizing the
recognition pin inside the monitor for HDCP authentication between a player and the monitor.