background image

SAMSUNG IPX-G5X0 

Installation Manual v1.0

Mar 2016

IPX-G5X0 Series Installation 

 

 

The IPX-G5X0 series gateways provide interfaces to a number of protocols such as PRI, FXS and FXO. 

It interfaces with the Samsung Communication Manager (SCM) by SIP protocol and can be extended to 
remote locations as a survivable gateway.   

 
 
To install an IPX-G5X0 Series Media Gateway you first have to setup your gateway information in the 

Samsung Communication Manager (SCM). Additionally some basic information must be set within the 
IPX-G5X0 Series system. 

The  IPX-GX0  Series  is  compatible  with  SCM  software  version  5.4  or  higher.  If  your  SCME  software 

version is prior to version 5.4, you must upgrade the SCM first. Please refer to the SCM documentation 
for upgrade instructions.   

 
 

Summary of Contents for IPX-G5X0 series

Page 1: ...SAMSUNG IPX G5X0 Installation Manual v1 0 Mar 2016 1 ...

Page 2: ...ly installing and operating the product Every effort has been made to eliminate errors and ambiguities in the information contained in this document All reasonable care has been made to ensure that this document is accurate SAMSUNG Electronics Co Ltd disclaims all liabilities for damages arising from the erroneous interpretation or use of information presented in this manual If you have any commen...

Page 3: ... used to distinguish between the main content and console output screen text Bold Courier New font will indicate the value entered by the operator on the console screen Revision History Revision Date Of Issue Remarks 1 0 Mar 2016 First Version Provides information or instructions that the reader should follow in order to avoid personal injury or fatality Provides information or instructions that t...

Page 4: ...SAMSUNG IPX G5X0 Installation Manual v1 0 Mar 2016 4 Table of Contents ...

Page 5: ...4 port FXO 2 port PRI No Card Type Limit IPX G520S 20 port FXS Expansion Cabinet Optional Power Redundancy Expandable to maximum of 6 cabinets 240 ports 50p Champ Connector IPX G540S 40 port FXS Expansion Cabinet Optional Power Redundancy Expandable to maximum of 6 cabinets 240 ports 50p Champ Connector Station Trunk Capacity Max stations FXS port 256 136 port power redundancy SIP Phone Survivabil...

Page 6: ...remote locations as a survivable gateway To install an IPX G5X0 Series Media Gateway you first have to setup your gateway information in the Samsung Communication Manager SCM Additionally some basic information must be set within the IPX G5X0 Series system The IPX GX0 Series is compatible with SCM software version 5 4 or higher If your SCME software version is prior to version 5 4 you must upgrade...

Page 7: ...IPX G5X0 Server AC Power Cord RJ45 to DB9 Serial Cable Gateway Link Setting Begin by creating a new gateway link in the SCM Administrator at Configuration Gateway Gateway Link Setting Enter a gateway Name Local IP Address Public IP Address and enable or disable NAT Note If NAT is enabled then Public IP Address should be entered ...

Page 8: ...samsung by default You don t need to enter any IP addresses here These fields are not needed for this implementation Slot Configuration There are 4 slots on the back of the gateway This tells the SCM what is configured on each slot On the left side of the slot configuration tab enter the slot and expansion configuration of the gateway Select the option cards and expansion cabinets installed in the...

Page 9: ... IPX G500B has 2 internal hardware units the CMU and GWU The LAN IP Address will be assigned to CMU and GWU IP Address will be assigned to the GWU board If you have optional universal cards enter Slot IP Addresses for optional cards PRI cards need individual IP addresses etc If you selected to Use WAN enter WAN IP Address and WAN Subnet Mask The IPX G5X0 Series has an internal DHCP server If you w...

Page 10: ...g FXS phone users you may also use those Enter the Extension Number Name Application User ID Application Password Application User ID Authentication Password Profile Login ID Profile Login Passcode and PIN Number The Phone Type should be set to Analog FXS Phone Assigning Analog Phones Assign the created Analog FXS Phone to the Slot and Port of the gateway in the SCM at Configuration Gateway IPX Se...

Page 11: ... information for the new gateway in the SCM at Configuration Trunk Routing Route Basic configuration Select Register Type and set to Receive REGISTER and enter port 5060 The User Name should match the Gateway Name Enter the Gateway IP Address for Proxy Server and also add the proper Authentication User Name and Authentication Password Additional SIP Under the Additional SIP tab set the Call Authen...

Page 12: ...ute Basic Configuration Set the Register Type to Receive REGISTER and enter port 5060 Enter a unique User Name for this trunk This name must not be used elsewhere Then Enter the Gateway IP Address for Proxy Server and also add the proper Authentication User Name and Authentication Password You can also set access code for this trunk route Additional SIP Under the Additional SIP tab set Call Authen...

Page 13: ...t the slot you where your FXO card is installed Assign the created FXO Trunk Route to the Route Name Select other settings at this time such as CID Receive Support and Ring Destination Number SIP Trunk SIP Trunks are configured in the SCM Administrator at Configuration Gateway IPX Setting Gateway SIP Trunk The IPX G5X0 Series supports up to 4 SIP carriers Note SIP Servers must be entered as IP add...

Page 14: ... in the SCM Administrator at Configuration Gateway IPX Setting Gateway PRI Trunk Select the Gateway to edit and press the Change button Then select the Slot where the PRI card is installed Assign the created PRI Trunk Route to the Route Name and select the correct network mode TE Terminal Mode or NT Network Mode ...

Page 15: ...ess of the Expansion Cabinet and Sequence Number Connecting to the Serial Console Use the following steps to connect to the serial console Connect a serial cable to the console port of the system Run a serial terminal program I E PuTTY etc on your PC and set the baud rate to 38 400 The default login ID is admin The default Password is samsung Enter cli to set up the basic gateway configuration Wel...

Page 16: ... the Gateway Name This must match the Gateway Name in the SCM Configuration After all information is entered it will ask if you want to reset the system to apply the changes To reboot the system enter yes otherwise enter no Please enter network mode of this GW 1 Enter Networkmode 0 LAN 1 NAT Enter Key NAT Please enter WAN IP Gateway Subnet Mask of this GW 1 Enter WAN IP Address Enter Key 10 251 0 ...

Page 17: ... Key 10 251 0 1 3 Enter WAN IP Subnet Mask Enter Key 255 255 255 0 Please enter LAN IP Subnet Mask of this GW 1 Enter LAN IP Address Enter Key 192 168 0 1 2 Enter LAN IP Subnet Mask Enter Key 255 255 255 0 Please enter the IP Address of SCME 1 Enter SCME IP Address Enter Key 10 251 0 100 Please enter the name of this GW Max 30char 1 Enter Name of this GW Enter Key G500_default G500Site1 End of Con...

Page 18: ... GW 1 Enter LAN IP Address Enter Key 192 168 0 10 2 Enter Gateway Address Enter Key 192 168 0 1 3 Enter Subnet Mask Enter Key 255 255 255 0 Please enter the IP Address of SCME 1 Enter SCME IP Address Enter Key 192 168 0 100 Please enter the name of this GW Max 30char 1 Enter Name of this GW Enter Key G500_default End of Configuration To apply it please restart the system Do you want to restart yes...

Page 19: ...which this expansion cabinet will be connected to Note The IPX G520S G540S LAN port should be connected to the same LAN network as the IPX0 G500 Assign the sequence number from 1 to 6 for this expansion cabinet It should be unique for each gateway After all information is entered it will ask if you want to reset the system to apply the changes To reboot the system enter yes otherwise enter no Plea...

Page 20: ... the gateway software you have to upload the software to the SCM You can upload it at Configuration Gateway IPX Setting Gateway File Upload Select the Board Type and press the Search button to browse your file system for the gateway software Select the gateway software then press the Send button to upload it Example Board Types IPX SYS IPX G500B software IPX ECU IPX G520S G540S software IPX PRI 1P...

Page 21: ...1 Upgrade Configuration After uploading the file to the SCM set the upgrade configuration at Configuration Gateway IPX Setting Gateway Upgrade Configuration Enter the Gateway Version to update the Transfer Protocol tftp or ftp Port Login ID and Password ...

Page 22: ... software hardware version at Configuration Gateway IPX Setting Gateway Package Upgrade Select the target to update software and press the Change button Then check the target to update software and press the Upgrade or Apply button Then the gateway will then be updated and reboot automatically ...

Page 23: ... FTP server and put the software on it so that the gateway can download it For a manual update you have to access the GWU board To access it you will need a Y type connector to divide the console port of IPX 500B Console port 1 is for CMU and 2 is for GWU IPX G500B CMU software update Connect the serial cable to Console Port 1 of the IPX G500B Baud Rate 38 400 Enter ID and Password to log on Defau...

Page 24: ...38 400 Enter ID and Password to log on Default ID admin Default Password samsung Change the directory on your FTP Server where the software can be downloaded o For example cd tmp Enter the following to download and upgrade the software admin IPT ECU tmp wget ftp ID PASSWORD FTP Server IP ECU Package Name admin IPT ECU tmp upgrade ECU Package Name admin IPT ECU tmp reboot 1PRI 2PRI Card Update Conn...

Page 25: ...Baud Rate 38 400 Enter ID and Password to log on Default ID admin Default Password samsung Enter cli to set up the basic gateway configuration Select 4 Factory Reset It will ask again to confirm the selection Enter yes GW Setup Manager 1 Setup basic configuration 2 Show current configuration 3 Show version 4 Factory Reset 5 Exit Please select the number 4 This will clear all configurations Do you ...

Page 26: ...5ESS5 in SCM 3 Test calling from FXS to PRI a Pick up PhoneA and dial PhoneB TRUNK NUMBER PHONE NUMER Ex 99 2001 b Ensure the call connects and has two way audio 4 Test calling from PRI to FXS a Make an incoming call with PRI assigned DID number to PhoneA b Check that the PhoneA is ringing c Answer and ensure the call connects and has two way audio 5 Test that FXS ringing stops when call is termin...

Page 27: ...All rights reserved Information in this manual is proprietary to SAMSUNG Electronics Co Ltd No information contained here may be copied translated transcribed or duplicated by any form without the prior written consent of SAMSUNG Information in this manual is subject to change without notice ...

Reviews: