Samsung Electronics
4-27
Troubleshooting
4-3 Buyer-Region Code Setting Method
4-3-1 Inserting Region Code after replacing the Main PBA
[Reference]
- After replacing the Main PBA and System Micom (IC1302), the region code should be inserted.
- The unit will not work properly if you do not insert the correct region code.
- You must use the remote control.
1. Press the “TUNER MEMORY” button on the remote control for 4-5
seconds
2. After step (1), you should see the “T-MODE” message display on
the VFD. Press the “down” direction button during this message.
The “T-MODE” indicator on the VFD only appears for a very
short time.
3. After step (2), you can see “TEST − − −” on the VFD.
Insert the number “46” to select the Region Code.
4. After step (3), you can see “− − −” on the VFD.
Insert the Region Code (see Table on next page) corresponding to
the model and area in which you reside in using the “0-9” buttons on
the remote control.
T-MODE
TEST − − −
2
1
− − −
Summary of Contents for HT-C5200