SAMSUNG Proprietary-Contents may change without notice
This Document can not be used without Samsung's authorization
Flow Chart of Troubleshooting
9-17
9-11. DCS Receiver
Yes
No
Resolder F100, C118, L112
F100
Pin 8
≥
-70dBm
Pin 9
≥
-70dBm
Yes
Resolder PAM100
Yes
No
Check ANT Switch
control circuit
Check PAM100
Pin9=H, Pin10 = L
No
Yes
No
Resolder PAM100, C152, C151,
L109, L114, C117
Yes
PAM100 Pin15
≥
-
65dBm
RX ON
Cell Power : -60dBm
①
PAM100 Pin17
≥
-68dBm
②
③
Resolder L107,L108,L110,L111
Check UCP200
END