8-3. LOGIC
8-3-1. Power On
Power switch on
NG
Check the VBAT Voltage
C219 or C214 >=3.3V
1.Charge the Battery.
2.If 0V,put more lead C219,C214
NO
Change the UCP200
Check the clock
DCX100 = 26Mhz ?
Check the initial operation
Check the clock generation circuit
Resolder OSC200
Download
Yes
Yes
Yes
NO
NO
L200(VDD_GSM_CORE_1V2)=
1.2V?
L201(VDD_IO_LOW_1V8)=
1.8V?
Yes
NO
Check the clock at
OSC200 =32KHz?
NO
Check the current c
onsumption
>= 100mA?