17
4. Troubleshooting
Weight Sensor
Error
Code
Gas Sensor Error Case (E-1X)
Solution
Page
E-31
Open (When value of HEX is above “FF” for 5 seconds)
Check Sensor .
E-32
Short
E-33
In case the initial value of HEX is under “14” for 30
seconds while a weight sensor in operation .
E-34
In case the initial value of K calculated by a weight
sensor is above and under “±28” as value of HEX .
E-35
In case the value of A is “-” as a weight sensor calculates .
E-36
In case the door opens during sensor cooking .
Cancel the present mode and
restart from the begining .
Easy/Ph Sensor
Error
Code Easy/PH Sensor Error Case (E4)
Solution
Page
E-41
Open
Check Sensor .
E-42
Short
E-43
T1 Max Time Error
E-44
Dry Up
Insert food and restart .
E-45
Cooling Error (3minutes)
Remove moisture from sensor and restart .
E-46
Primary Open Error(3minutes)
Check Sensor .
E-47
The door opens during cooking
Cancel the present mode and restart from the
begining .
Humidity Sensor
Error Code Humidity Sensor Error Case (E-6X)
Solution
Page
E-61
Open
Check Sensor .
E-62
Short
E-63
T1 Max Time Error
Others
Error
Code
Others (E-0X, Letter)
Solution
Page
-SE- Key Short Error (10 seconds)
Turn off set and restart .
E-02 Cooking Time Setting Over Error (MWO)
Check each mode’s setting time .
E-03 Cooking Time Setting Over Error (Grill)
E-04 Cooking Time Setting Over Error
(Convection)
E-05 Cooking Time Setting Over Error
(Combination)
E-06 It fails to sense that the swing heater has
stopped for 20 seconds during cooking .
Check Swing heater’s motor and connector .
18 Page
18 Page
18 Page
18 Page
19 Page
19 Page
19 Page
20 Page
20 Page
20 Page
21 Page
22 Page
23 Page
23 Page
23 Page
27 Page
31 Page
Summary of Contents for GE89M-S