How To Wire The Electric Meters
It is now a requirement to measure the electricity being used by the heat pump so the end user can see what the unit costs to run. We
provide a Smart Process electric meter with every unit. Ideally it should measure the total draw for the heat pump (outdoor and indoor
unit combined). The outdoor unit takes most of the current so in many installations it will only be used to measure the outdoor unit.
Valve Z2
Power In
Valve Z1
Valve Z2
Valve Z1
Pump Z1
Pump Z1
Run Signal to
Heat Pump
B20
B22
B19
B22
Power In
Header,
Buffer or
Heat
Exchanger
Neutral fom
mains and out
to heat pump
Live to heat pump
Live from mains