5.
TROUBLESHOOTING
SENS R5
5
5-28
5-5 Others
5-5-1 BATTERY
z
Battery Time Standard
-
LCD : Lowest Brightness, Power Option : Maximum Battery Mode,
Benchmark Program : BatteryMark 4.0.1, Wireless Lan : Off , Close
all program(Ex:V3), Using New Battery.
- FIRENZE : Battery life time is 5hr
5-5-2 FAN Control/Thermal/Noise
z
Basic Mode
CPU
Voltage Address
(for CPU
temperature)
(for Video
temperature)
SPEED
(Volt)
(Hexa)
RPM
Noise
CPU Sensor(on/off) Video Sensor(on/off)
2.5
73
1800 rpm
26dBA
3.0
8C
2000 rpm
30dBA
55/50
65/61
3.5
A0
2250 rpm
32dBA
60/55
4.0
B9
2500 rpm
34dBA
67/62
I Level
4.5
D2
2700 rpm
36dBA
75/70
II Level
4.5
D2
2700 rpm
36dBA
80/75
110/90
III Level
4.5
D2
2700 rpm
36dBA
85/80
OS Throttling
90/85
ACPI Notify
95
Dos Throttling
95/90
Shutdown
100