Installation
English
26
Installation
STEP 3
Connect the electrical wiring (for electric models)
Before connecting the electrical wiring, make sure you have read the “
” section on page
3-wire system
A B
C L2
L1
D
E
A.
External ground connector
B.
Neutral grounding wire (white)
C.
Center silver-colored terminal block
screw
D.
Neutral wire (white or center wire)
E.
3/4” (1.9 cm) UL-listed strain relief
1.
Loosen or remove the screws from the
center terminal block.
2.
Connect the neutral wire (white or
center wire) of the power cable to the
center, silver-colored terminal screw of
the terminal block. Tighten the screws.
3.
Connect the other wires to outer
terminal block screws. Tighten the
screws.
4.
Tighten the strain relief screws.
5.
Insert the terminal block cover into the
rear panel of the dryer. Then, secure the
cover with a hold-down screw.
CAUTION
• To convert from the 4-wire system
to 3-wire system, connect the ground
strap to the terminal block support to
ground the dryer frame to the neutral
conductor.
• Ring-type terminals are recommended.
If using strap terminals, make sure they
are tightened.
• Before Installing the Dryer, confirm
240 V is present between L1 and L2 at
the power receptacle. If the Voltage is
low, it may not dry properly. Review
the “
Untitled-5 26
7/3/2020 5:52:19 PM
Summary of Contents for DVG45T6020 Series
Page 1: ...Dryer User manual DVE G 45T6020 Untitled 5 1 7 3 2020 5 52 13 PM ...
Page 63: ...Memo Untitled 5 63 7 3 2020 5 52 35 PM ...
Page 65: ...Sèche linge Manuel d utilisation DVE G 45T6020 Untitled 2 1 7 7 2020 11 50 19 AM ...
Page 127: ...Mémo Untitled 2 63 7 7 2020 11 50 43 AM ...
Page 129: ...Secadora Manual del usuario DVE G 45T6020 Untitled 3 1 7 7 2020 12 03 09 PM ...