background image

E-

3

 

Contents

  S

AFETY

 P

RECAUTIONS

 

 .....................................................................          

2

  B

EFORE

 I

NSTALLING

 

THE

 DMS2

 

 ...................................................          

4

  A

CCESSORIES

 

 .....................................................................................          

  V

IEWING

 

THE

 P

ARTS

 

 ........................................................................          

6

  P

RODUCT

 D

IMENSIONS

 

 ...................................................................          

8

  S

YSTEM

 A

RCHITECTURE

 

 ...................................................................          

9

  C

OMPATIBLE

 D

EVICES

 

 .....................................................................           

10

  I

NSTALLING

 

THE

 DMS2 

 

 ................................................................           

12

  S

ETTING

 

THE

 C

OMPUTER

 E

NVIRONMENT

 

 ......................................           

21

  S

ETTING

 

THE

 DMS2

 

 ......................................................................           

23

  T

RACKING

 

 .........................................................................................           

35

  PIM S

ETTING

 

 ..................................................................................           

47

  S

ETTING

 

THE

 P

OWER

 D

ISTRIBUTION

 

 ..............................................           

49

  A

PPENDIX

 

 .........................................................................................           

52

MIM-D00A_DMS2_IM_E 32138-2.indd   3

2010-07-22   ソタネト 2:31:21

Summary of Contents for DMS2

Page 1: ...Data Management Server2 MIM D00A Air Conditioner installation manual DB98 32138A 3 E imagine the possibilities ThankyouforpurchasingthisSamsungproduct MIM D00A_DMS2_IM_E 32138 3 indd 57 2010 09 03 오후 2 12 02 ...

Page 2: ...WARNING CAUTION Do not use inflammable gases near the DMS2 Do not install the DMS2 in a location where it will come into contact with combustible gases machine oil sulphide gas etc Avoid locations where acid alkali solution or special spray is used Choose a location that is dry and sunny but not exposed to direct sunlight Suitable temperature is between 0 C 32 F and 39 C 102 2 F Do not spill water...

Page 3: ... THE PARTS 6 PRODUCT DIMENSIONS 8 SYSTEM ARCHITECTURE 9 COMPATIBLE DEVICES 10 INSTALLING THE DMS2 12 SETTING THE COMPUTER ENVIRONMENT 21 SETTING THE DMS2 23 TRACKING 35 PIMSETTING 47 SETTING THE POWER DISTRIBUTION 49 APPENDIX 52 MIM D00A_DMS2_IM_E 32138 2 indd 3 2010 07 22 ソタネト 2 31 21 ...

Page 4: ...e TCP IP DHCP is used to automatically assign IP addresses In other words the IP address of the host is supported only when the PC is on 3 Installation connection wire The LAN cable and the communication cables from centralized controllers interface modules must be installed in such a way that the wires can be connected to the DMS2 with ease Note TheDMS2isaserverandsupportsstaticIPand DynamicIP To...

Page 5: ...n your country or service provider Accessories The DMS2 must be installed by a trained installer Ensure the main power is turned off before installing the DMS2 Be sure to use adapter and power cable we provide The power cable and the communication cable must be installed according to the national electrical wiring regulations MIM D00A_DMS2_IM_E 32138 2 indd 5 2010 07 22 ソタネト 2 31 22 ...

Page 6: ... Alive CPU operation indicator Blinks in orange with 1 second intervals during normal operation Ethernet Linked Internet connection indicator Turns green during normal connection Ethernet Active Internet data transmission reception indicator Blinks in orange during normal transmission reception COM1 5 TX Channel 1 5 Centralized controller Interface module Data transmission Indicator Blinks in gree...

Page 7: ...2 error status using this terminal SD card socket Sub memory for program update and set information saving socket RS485 Communication Terminal Connect for RS485 communication with devices such as centralized controller Interface module COM1 COM5 Ethernet Terminal Connect LAN cable Cable tie groove Groove for arranging cables Cable tie groove SD Card Socket Serial Terminal Power Terminal Reset Butt...

Page 8: ...tion switch Main Board Sub Board DMS2 Interior Main Parts Viewing the Parts Continued Note If you need external circuit configuration consult with the manufacturer Refer to page 20 for DI contact input operation Product Dimensions MIM D00A_DMS2_IM_E 32138 2 indd 8 2010 07 22 ソタネト 2 31 23 ...

Page 9: ...ame communicationchannel onlyoneofthemwillcommunicateaccordingtothe communicationchannelmodesettingof SystemSettings Tracking Therefore donotconnectthecentralizedcontrollerandinterfacemoduletothesame communicationchannel Ifyousetthecommunicationchannelmodeasinterfacemodule virtualcentralized controlleraddresswillbeassigned Thereforepleaseawareofthatifyousetthe centralizedcontrolleraddressasvirtual...

Page 10: ...nterface module MIM B04A DVM DVM PLUS etc MIM B13 DVM PLUS II etc MIM B13A DVM PLUS II DVM PLUS III DVM PLUS IV etc MIM B13B 6 Watt hour Meter RS485 comm type Connected with SIM Needed for power distribution Please consult Samsung for compatible power meters Pulse type Connected with PIM Pulse Width 20 400 ms Pulse 1 10000 Wh Pulse Products with are not Samsung products and must be purchased separ...

Page 11: ...er 1 channel total 80 units are connectable when connecting interface module to DMS2 directly 256 units are connectable when using centralized controller SIM PIM 8 Maximum 8 SIM PIM units can be connected Watt hour Meter 64 Maximum 8 units can be connected to 1 SIM PIM Maximum Devices Attachable MIM D00A_DMS2_IM_E 32138 2 indd 11 2010 07 22 ソタネト 2 31 25 ...

Page 12: ...Separate the installation plate on the rear side of DMS2 2 Fix the installation plate on the wall using 4 screws 3 Hang the DMS2 on the groove which is on the top of the installation plate MIM D00A_DMS2_IM_E 32138 2 indd 12 2010 07 22 ソタネト 2 31 25 ...

Page 13: ...sistant holes Screws for assistant hole are not provided by our company 5 If you install DMS2 inside of the wall or wiring from the rear side is needed use wiring groove on the bottom of DMS2 To prevent breakdown and damage of DMS2 and for safe usage itisrecommendedtoinstallDMS2onthewall MIM D00A_DMS2_IM_E 32138 2 indd 13 2010 07 22 ソタネト 2 31 25 ...

Page 14: ...erminal Arrange the adapter as the right figure 3 Separate 1 terminal block from 5 terminal blocks which are attached to RS485 communication terminal Then connect centralized controller communication cable C1 C2 to the terminal block C1 A C2 B 4 Connect LAN cable to the Ethernet terminal of DMS2 Then arrange it using cable tie 5 Fasten the bottom cover of DMS2 and fix it using 2 screws Maximum16ce...

Page 15: ...ange the adapter as the right figure 3 Separate 1 terminal block from 5 terminal blocks which are attached to RS485 communication terminal Then connect interface module communication cable R1 R2 to the terminal block R1 A R2 B 4 Connect LAN cable to the Ethernet terminal of DMS2 Then arrange it using cable tie 5 Fasten the bottom cover of DMS2 and fix it using 2 screws Maximum80interfacemodulescan...

Page 16: ...er terminal Arrange the adapter as the right figure 3 Separate 1 terminal block from 5 terminal blocks which are attached to RS485 communication terminal Then connect SIM PIM communication cable C1 C2 to the terminal block C1 A C2 B 4 Connect LAN cable to the Ethernet terminal of DMS2 Then arrange it using cable tie 5 Fasten the bottom cover of DMS2 and fix it using 2 screws Maximum8SIM PIMunitsca...

Page 17: ...int control signal Pattern 2 Level Emergency stop Commands that stop all indoor unit operation and disable remote control when inputting contact point control signal In level emergency stop status it will not be controlled even if the command is set from upper controller Pattern 3 Level Operation Stop Level signal input timing It changes operation stop status of all indoor units Pattern 4 pulse Op...

Page 18: ...t setting screen appears again with all items are disabled Note Pattern1issetasfactorysetting DMS2hastotal10DIports However actuallyusedDIports areCh1andCh2 andtherestoftheports Ch3 Ch10 are foradditionalfunctions Therefore makesuretoconnect Ch1orCh2whenusingit ForDO Ch1andCh2arecurrentlyusedinsideofDMS2 Ch9andCh10arereservedincaseofneed Thereforeyou canonlyuseCh3 Ch8 5 MIM D00A_DMS2_IM_E 32138 2 ...

Page 19: ...al of port 1 changes from ON to OFF all indoor units will be given Stop command 3 If the contact signal of port 2 is OFF you cannot control all indoor units using remote controller 4 If the contact signal of port 2 changes from OFF to ON you can control all indoor units using remote controller 5 If the contact signal of port 2 changes from ON to OFF you cannot control all indoor units using remote...

Page 20: ...ontact signal control Pattern 4 Pulse signal control Emergency Stop Resume Operation No Connection Operation Stop A C Enable Disable remote control Operation Stop A C A C Installing the DMS2 Continued DI Digital Input Circuitry according to Control Switch Pattern MIM D00A_DMS2_IM_E 32138 2 indd 20 2010 07 22 ソタネト 2 31 30 ...

Reviews: