safety information

 

_05

ENGLISH

Install the supplied cables firmly. Fix them securely so that external force is not 

exerted to the terminal block.

• 

If the connection is loose, heat may generate and cause electric shock or fire.

Use a rated circuit breaker only.

• 

Never use steel wires or copper wires as a circuit breaker. It may cause fire or unit malfunction.

Use an exclusive power source for the air conditioner.

• 

Potential risk of electric shock or fire.

Do not put undue stress or place heavy object on the power cable.
Do not bend the power cable excessively.

• 

Potential risk of fire or electric shock.

Always verify that electric connections (cable entry, section of leads, protections...) 

are compliant with the electric specifications and with the instructions provided in the 

wiring scheme. 

Always verify that all connections comply with the standards applicable to the 

installation of air conditioners. 
Use a receptacle that has a ground terminal. The receptacle must be used exclusively 

for the air conditioner.

• 

Improper electrical grounding may cause electric shock or fire.

Be sure to ground the unit. Do not connect the ground wire to gas or water pipes, 

lighting rods, or telephone grounding lines. 

• 

If the unit is not properly grounded, electric shock may result.

Always verify that a suitable grounding connection is available. 
Disconnect the air conditioner from power supply before it is repaired or 

disassembled.

CAUTION SIGNS

Connect the refrigerant tubes first then the electrical lines, when installing the unit.
Always disassemble the electric lines before the refrigerant tubes.
Verify that the air conditioner is connected to the power supply in accordance with the 

instructions provided in the wiring diagram included in the manual.
The manufacturer shall not be responsible for damage originating from unauthorized 

changes or the improper connection of electric and hydraulic lines.  

Failure to comply with these instructions or to comply with the requirements set 

forth in the “Operating limits” table, included in the manual, and shall immediately 

invalidate the warranty.
Ensure no water gets into the air conditioner.

• 

Potential risk or electric shock.

Turn off the air conditioner using the provided remote control or control accessory  

(if provided). Do not unplug to turn off the unit (unless there is an immediate danger).
Do not open the front grille during operation.

• 

Potential risk of electric shock or unit malfunction.

Cool air should not flow directly towards people, pets, and plants.

• 

It is harmful to your health, pets, and plants.

Do not run the air conditioner for an extended period of time in a room with the door 

closed or with babies, elderly or disabled people.

• 

Open the door or windows to ventilate your room at least once an hour to prevent oxygen shortage.

Do not drink drain water coming out of the air conditioner.

• 

Potential risk of health hazard.

Summary of Contents for DC18ET

Page 1: ......

Page 2: ... your own air conditioner Cost Efficient System Your new air conditioner not only provides maximum cooling power in the summer but can also be an efficient heating method in the winter with the advanced Heat pump system This technology is up to 300 more efficient than electrical heating so you can further reduce its running cost Now meet year round needs with one air conditioner Flexible installat...

Page 3: ...mpt Do NOT disassemble Do NOT touch Follow directions carefully Unplug the power plug from the wall socket Make sure the machine is grounded to prevent electric shock Call the contact center for help Recommended instructions or useful information for use These warning signs are here to prevent injury to you and others Please follow them carefully After reading this section keep it in a safe place ...

Page 4: ...nsult the contact center Consult the place of purchase or a contact center to disassemble or reinstall the air conditioner Potential risk of unit malfunction water leakage electric shock or fire Consult the place of purchase or contact center to install the air conditioner Improper installation carries a risk of unit malfunction water leakage electric shock or fire If installing in specialty areas...

Page 5: ...nect the air conditioner from power supply before it is repaired or disassembled CAUTION SIGNS Connect the refrigerant tubes first then the electrical lines when installing the unit Always disassemble the electric lines before the refrigerant tubes Verify that the air conditioner is connected to the power supply in accordance with the instructions provided in the wiring diagram included in the man...

Page 6: ...ol reception error may occur due to the ballast of the lighting apparatus For maximum safety installers should always carefully read the following warnings Do not install the air conditioner in following places Place where there is mineral oil or arsenic acid Resin parts flame and the accessories may drop or water may leak The capacity of the heat exchanger may reduce or the air conditioner may be...

Page 7: ...conditioner If the remote control is not used for a long period of time remove the batteries to prevent leakage of electrolyte When cleaning the outdoor unit touch the heat exchanger radiator fins with extreme care Wearing thick gloves can protect your hands Make sure that the condensed water dripping from the drain hose runs out properly and safely Store the operation and installation manual in a...

Page 8: ...able and the connection cord of the indoor and outdoor units in the protection tube Connect the power cable to the auxiliary circuit breaker You must keep the cable in a protection tube Keep distances of 50mm or more between power cable and communication cable Maximum length of power cable is decided within 10 of power drop If it exceeds you must consider another power supplying method The circuit...

Page 9: ...g your air conditioner CLEANING AND MAINTAINING THE AIR CONDITIONER 12 12 Cleaning the filter 12 Slim duct type 13 MA duct type 14 Maintaining your air conditioner 14 Periodical checks 15 Internal protections via the unit control system APPENDIX 16 16 Troubleshooting 17 Operation ranges INSTALLING YOUR AIR CONDITIONER 18 18 Installation part ...

Page 10: ...ool or warm with optimal efficiency Please read the user manual to get started and to make the best use of the air conditioner SLIM DUCT TYPE MA DUCT TYPE Your air conditioner may look slightly different from the illustration shown above depending on your model Air intake Air outlet Ceiling Air filter the return air side Air intake Air outlet Ceiling Air filter the return air side ...

Page 11: ... The air conditioner stops heating The air conditioner will operate automatically in De ice mode for 10 minutes The steam produced on the outdoor unit in De ice mode is safe No intervention is required after about 10 minutes the air conditioner operates again normally The unit will not operate when it starts to de ice Fan Fan may not operate for about 3 5 minutes at the beginning to prevent any co...

Page 12: ...r is cleaned with a vacuum or by hand washing Slim duct type 1 Way 1 Slide out the Air filter on the rear side panel to the right side Way 2 Take out the Air filter from the panel 2 Clean the Air filter with a vacuum cleaner or soft brush If dust is too heavy then rinse it with running water and dry it in a ventilated area For best conditions repeat every two weeks If the Air filter dries in a con...

Page 13: ... area For best conditions repeat every two weeks If the Air filter dries in a confined or humid area odors may generate If it occurs re clean and dry it in a ventilated area 3 Way 1 Insert the filter back in its original position Way 2 Insert the filter back in its original position The illustration shown above may differ from your depending on your model After cleaning the filter press the Filter...

Page 14: ...Indoor unit Clean the air filter 1 Clean the condensate drain pan 2 Thoroughly clean the heat exchanger 2 Clean the condensate drain pipe 2 Replace the remote control batteries 1 Outdoor unit Clean the heat exchanger on the outside of the unit 2 Clean the heat exchanger on the inside of the unit 2 Clean the electric components with jets of air 2 Verify that all the electric components are firmly t...

Page 15: ... when the heat pump is heating Anti protection of internal battery The compressor will be off to protect internal battery when the air conditioner operates in Cool mode Protect compressor The air conditioner does not start operating immediately to protect the compressor of the outdoor unit after it has been started If the heat pump is operating in Heat mode De ice cycle is actuated to remove frost...

Page 16: ...le for cooling model The fan speed does not change Check if you selected Auto or Dry mode The air conditioner automatically adjusts the fan speed to Auto in Auto Dry mode Timer function does not set Check if you press the Power button on the remote control after you have set the time Odors permeate in the room during operation Check if the appliance is running in a smoky area or if there is a smel...

Page 17: ... IF OUT OF CONDITIONS INDOOR OUTDOOR COOLING 21 C to 32 C 21 C to 54 C 80 or less Condensation may occur on the indoor unit with risk to have either water blow off or drops on the floor DRYING 21 C to 32 C 21 C to 54 C Condensation may occur on the indoor unit with risk to have either water blow off or drops on the floor If the cooling operation is used at over 32 C indoor temperature it does not ...

Page 18: ...QUESTIONS OR COMMENTS COUNTRY CALL OR VISIT US ONLINE AT Turkey 444 77 11 www samsung com tr SOUTH AFRICA 0860 SAMSUNG 726 7864 www samsung com za U A E 800 SAMSUNG 726 7864 8000 4726 www samsung com ae ...

Page 19: ... Thank you for purchasing this Samsung product To receive more complete service please register your product at www samsung com global register Duct Type Series Slim duct MA duct DC18ET DC24ET DC30ET DC36ET DC42ET DC48GT DC60GT DC72GT A S E DB98 29834A 1 ...

Reviews: