Samsung Electronics
Troubleshooting
5-1
5. Troubleshooting
5-1 No Power
Abnormal
Normal
Normal
Normal
Normal
Normal
Abnormal
Abnormal
Abnormal
Abnormal
Counect
the Power code
Check the
X-tal,SDA,SCL port
of IC201S
Check the
(33)Pin (H-Drive)
of IC201S
Check the
130V- A Line
Check the
3.3V-A,8V-A Line
of IC201S
Check/Replace
IC802
Replace
IC201 S
Check the
FBT,D805(D806)
Check the
12.5V-A Line
Check the
FD801S, D807, IC801S
or AC-Fuse
Check / Replace
Q401
Summary of Contents for CT26F7SWX/XAP
Page 2: ...ELECTRONICS Samsung Electronics Co Ltd JULY 2002 Printed in Korea AA82 00088A ...
Page 14: ...3 4 Samsung Electronics MEMO ...
Page 23: ...2 4 MEMO ...
Page 25: ...9 2 MEMO ...
Page 34: ...Schematic Diagrams 10 4 Samsung Electronics 10 4 MAIN 4 4 ...
Page 40: ...7 6 Samsung Electronics MEMO ...