3. Disassembly and Reassembly
3-1 Replacement of Magnetron
Remove the magnetron including the shield case, permanent magnet, choke coils and capacitors (all of which
are contained in one assembly)
Parts
Explaination Photo
Explaination
Magnetron,
Motor
Assembly
and Lamp
Duct-MGT-L
Nut-Flange
Duct-Fan
Duct-MGT-R
Magnetron
1.
Remove the outer panel .
NOTE
: Before servicing, make
sure to discharge electric charge
remaining on the high voltage
capacitors or wait for more than 5
min .
2.
Remove the back cover .
3.
Disconnect all leadwires from the
magnetron .
4.
Remove screws securing the duct-
MGT and duct-fan .
5.
Remove the nut-flanges securing
the magnetron by using a box
wrench .
6.
Take out the magnetron very
carefully .
NOTE1:
When removing the magnetron, make sure that its antenna does not hit any adjacent parts, or it may be
damaged .
NOTE2:
When replacing the magnetron, be sure to remount the magnetron gasket in the correct position and
make sure the gasket is in good condition .
3-2 Replacement of High Voltage Tranformer
Parts
Explaination Photo
Explaination
HVT
LVT
H. V. Trans
4 Mounting Bolts
1.
Discharge the high voltage capacitor .
2.
Disconnect all the leads .
3.
Remove the mounting bolits securinh the HVT .
4.
Reconnect the leads correctly and firmly.
Summary of Contents for CM1329A