Step 5. Plug in and place
WARNING
•
BEFORE OPERATING OR TESTING, follow the grounding requirements on pages
in this manual. Improper connection of the grounding plug can result in a
risk of electric shock.
•
All gas ranges come with a power cord.
The power cord is connected to the rear of
the range. Please review "
" on pages
.
•
All U.S. and Canadian models are produced with a 3-wire, 120-volt, 60-Hertz
electrical system. The entire system, including the power cord, is preinstalled and
prewired at the factory. Altering any part of this system may result in a short or
overload.
Gas Range Plug
1.
The cable tie at the rear of the unit
features a lever that unties the power
cable. To release the tie, do not cut it loose.
Instead, use the lever to release the tie.
2.
Plug in the power cord. Make sure the
outlet meets local or national electrical
codes as referenced on pages
.
3.
Slide the range into place.
4.
Check the gas supply line to make sure
it did not get damaged and it stayed
connected during positioning.
5.
Check to make sure the back leg of the
range has slid into the anti-tip bracket.
Carefully tip the range forward to ensure
that the anti-tip bracket engages the back
brace and prevents tip-over.
Anti-Tip
bracket
*approximatel
1
3
/
8
” (35.1 mm)
Screw must enter wood
or concrete
NOTE
To install the Anti-tip bracket, release the leveling leg using pipe wrench because
Loctite is applied on Bolt for vibration unlocking. A minimum clearance of 1
3
/
8
”
(35.1 mm) is required between the range bottom and the kitchen floor.
To check if the bracket is installed and engaged properly, remove the kick panel
and look underneath the range to see that the leveling leg is engaged in the
bracket. Carefully tip the range forward. The bracket should stop the range within
4 inches (10.2 cm) of tipping. If it does not, the bracket must be reinstalled.
If the range is pulled from the wall for any reason, always repeat this procedure to
verify the range is properly secured by the anti-tip bracket. Never completely remove
the leveling legs or the range will not be secured to the anti-tip device properly.
Install_NX36R9966PS_DG68-01106A-02_EN.indd 23
7/18/2019 6:06:02 PM
Summary of Contents for Chef Collection NX36R9966P Series
Page 30: ...Memo Install_NX36R9966PS_DG68 01106A 02_EN indd 30 7 18 2019 6 06 08 PM ...
Page 31: ...Memo Install_NX36R9966PS_DG68 01106A 02_EN indd 31 7 18 2019 6 06 08 PM ...
Page 62: ...Notas Install_NX36R9966PS_DG68 01106A 02_MES indd 30 7 19 2019 12 12 51 PM ...
Page 63: ...Notas Install_NX36R9966PS_DG68 01106A 02_MES indd 31 7 19 2019 12 12 51 PM ...
Page 94: ...Notes Install_NX36R9966PS_DG68 01106A 02_CFR indd 30 7 18 2019 6 49 15 PM ...
Page 95: ...Notes Install_NX36R9966PS_DG68 01106A 02_CFR indd 31 7 18 2019 6 49 15 PM ...