- 7 -
Parts
Explanation Photo
Explanation
Assy-Working
Coil
3. Remove the Adiabatic-Coil by using
some tool.
(Do not remove by hand. Adiabatic
can be easily broken.)
4. Disconnect all lead wires from the
Assy-Working Coil.
5. For the replacement of Sensor-Top,
pull the Sensor-Top toward bottom
side.
6. Rotate the Sensor-Wire by
90degree until the Sensor-Top can
be remove from the Coil-Working.
6. Rotate the Spring ETC-Base by
90degree in order to replace.
3-3 Replacement of the Assy-Working Coil
pull & rotate
pull & rotate