- 10 -
Parts
Explanation Photo
Explanation
Assy-Induction
Module
1. Remove 12 screws(4-side direc
-
tion) securing the Assy-Induction
Module to the Assy Case Burner.
2. Disconnect Assy Wire Harness-P
from the Terminal Block.
3. After replacement, connect the
wire according to carved guide.
Warning
Wire connecting position is very improtant.
Please keep attention.
4. Remove the screw(upper side)
securing the Assy-Inverter
Module to the Case-Induction A.
* screw-1 type : 6002-000630
(M3,L8)
* ‘PCB’ marking is carved at the
side of screw.
3-5 Replacement of the Assy-Induction Module
wire connection guide
wire connection guide
Blue
wire
Blue
wire
Brown
wire
Brown
wire
Assy-Inverter
Module L
Assy-Inverter
Module L
Assy-Inverter
Module R
Assy-Inverter
Module R
Assy PCB Parts
Assy PCB Parts
Screw-1
Screw-1
Screw-1
Screw-1
‘PCB’ marking
‘PCB’ marking