![Samsung Bixolon SRP-500 Operator'S Manual Download Page 28](http://html1.mh-extra.com/html/samsung/bixolon-srp-500/bixolon-srp-500_operators-manual_4064999028.webp)
47
ESC ? n
[Name]
Cancel user-defined characters
[Format]
ASCII
ESC
?
n
Hex
1B
3F
n
Decimal 27
63
n
[Range]
32
≤
n
≤
255
[Description]
Cancels user-defined characters.
[Notes]
•
This command cancels the pattern defined for the character code specified
by n. After the user-defined characters is cancelled, the corresponding
pattern for the internal character is printed.
•
This command deletes the defined pattern for the specified code in the
character font selected by the "ESC !" command.
•
If a user-defined character has not been defined for the specified character
code, the printer ignores this command.
[Reference]
ESC &, ESC %
ESC @
[Name]
Initialize printer
[Format]
ASCII
ESC
@
Hex
1B
40
Decimal 27
64
[Description]
Clears the data in the print buffer and resets the printer
mode to the mode that was in effect when the power was
turned on.
[Notes]
•
The DIP switch settings are not checked again.
•
The data in the receive buffer is not cleared.
48
ESC D n1... nk NUL
[Name]
Set horizontal tab positions
[Format]
ASCII
ESC
D
n1...nk NUL
Hex
1B
44
n1...nk 00
Decimal 27
68
n1...nk 0
[Range]
1
≤
d
≤
255
0
≤
k
≤
32
[Description]
Sets horizontal tab positions.
•
n specifies the column number (counted from the beginning of the line) for
setting a horizontal tab position.
•
k indicates the total number of horizontal tab positions to be set.
[Notes]
•
The tab position is set at [character width x n] from the beginning of the
line. The character width includes the right-side space of the character,
and is twice the normal value when double-width is specified.
•
This command deletes horizontal tab positions that have already been set.
•
When "n = 8" has been set for the horizontal tab position, the printing
position moves to the ninth digit when HT is executed.
•
Up to 32 tab positions can be set. Data exceeding 32 tab positions is
processed as normal data. Input <n>k in ascending order and place a NUL
code <00>H at the end when <n>k is less than or equal to the preceding
value <n>k-1, tab setting is finished and the following data is processed as
normal data.
•
ESC D NUL cancels all horizontal tab positions.
•
The previously specified horizontal tab positions do not change, even if the
character width changes.
[Default]
The default tab positions are at intervals of 8 characters
(columns 9, 17, 25, ...) for the font B (12 x 14).
[Reference]
HT
Summary of Contents for Bixolon SRP-500
Page 1: ...Samsung Elector Mechanics Printed In Korea 2003 2 Operator s Manual SRP 500...
Page 16: ...23 Page 3 PC860 Portuguese 24 Page 4 PC 863 Canadian French...
Page 17: ...25 Page 5 PC 865 Nordic 26 page 16 CP1252 WinLatin1...
Page 18: ...27 page 17 PC 866 Russian 28 page 18 CP 852 DosLatin2...
Page 19: ...29 Page 19 PC 858 Euro 30 Page 21 MS DOS 862 Israel...
Page 20: ...31 Page 22 MS DOS 864 Arabic 32 Page 23 MS DOS 874 Thai...
Page 41: ...73 Memo...