PROBLEM

EXPLANATION / SOLUTION

The air conditioner does not
operate at all

The air conditioner does not
cool

The air flow direction does not
change when you set the air
flow blade swing switch to the
on position

Odours are permeated in the
room during air conditioning

Check that the circuit breaker used for the air conditioner
has not been triggered.
Check that the power cable is plugged into a wall socket and the
socket is switched on, if necessary.
Check that the correct operating mode has been selected
(cooling or airing).

Check that the correct operating mode has been selected.
The room temperature may be too low.
Dust may be blocking the air filter;
refer to page 9 cleaning instructions.
Check that there is no obstacle blocking the air flow into or out of the unit.

Check that the air conditioner has been switched on;
if necessary, turn the operating mode selection dial;
refer to page 7.

Air the room.

E-

9

HSI

L

GN

E

Summary of Contents for AW07P1HBA

Page 1: ...ondicionadordeaireadomésticosistemadetipoventana Reirigeración ClimatiseurdetypeFenêtre Refroidissement OarCondicionadodeWindow Type Refrigeracçã Condizionatored ariaperambientidafinestra Raffreddamento AW07P1HEA AW07P1HBA AW09P1HDA AW09P1HBA AW09P1HAA AW09P1HEA AW12P1HAA AW12P1HEA AW12P1HDA AW12P1HBA AWT12P1HEA AWT12P1HBA AW14P1HBA AW24P1HBA BB BC BD AW18P1HBA AW18P1HEA AW24P1HEA EB AWT18P1HEA EB...

Page 2: ...power source which must be installed in compliance with national wiring earthing and safety regulations If the power cord is damaged in any way it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard This device must be installed according to the national electrical rules The appliance must be installation that the plug should be easi...

Page 3: ...r motor can have adverse effects to the operation of other equipment under unfavorable mains conditions This equipment does not comply with the relevant technical standards for the limitation of voltage fluctuations and flicker Before connection this equipment to the power supply system please report to your suply authority and obtain the consent Do not connect other electric appliances to the sam...

Page 4: ...wer plug may differ according to the type of local power supply Inner air flow blades right left orientation Outer air flow blades up down orientation Air inlet Outside Ventilation lever Power Cable Air inlet Inside The air filter is located in side Operating mode selection dial Temperature control dial Air flow blade swing switch Air Outlet Coolest ...

Page 5: ...W Low fan speed HI COOL MED COOL LOW COOL Result The air conditioner starts up in Cool mode The fan starts up at the speed selected You can change modes at any time 2 To adjust the temperature turn the temperature control dial to the desired position Possible temperatures Between 18 C and 29 C inclusive Result The air conditioner starts cooling if the room temperature is higher than the selected t...

Page 6: ... the operating mode selection dial to the OFF position Result Result The air inside the room circulates and stale air is evacuated outside Otherwise push the ventilation lever to the left and the closed position The air simply circulates inside the room Result The air conditioner starts up in Fan mode Result The air conditioner stops operating 2 Set the operating mode selection dial to the HI FAN ...

Page 7: ...et the switch to the off position when the blades are in the desired position Again depending on the position of the unit in your room you can adjust the orientation of the outer air flow blades on the right hand side of the unit RECOMMENDATION When Adjust the blades to face Cooling Upwards Adjust the air flow blades to the desired position by pushing them upwards or downwards Temperature and Humi...

Page 8: ...lean the air conditioner Open the grille as much as possible 1 Grasp the lower part of the front grille and the front grille handle then open the grille The open angle of front grille has not to be exceeded 25 degree 2 Lift the front grille slightly and remove it from the front panel 3 Reassembling of front grille should be done in reverse order of disassembly If you Then Will not be using the air...

Page 9: ...t the circuit breaker used for the air conditioner has not been triggered Check that the power cable is plugged into a wall socket and the socket is switched on if necessary Check that the correct operating mode has been selected cooling or airing Check that the correct operating mode has been selected The room temperature may be too low Dust may be blocking the air filter refer to page 9 cleaning...

Page 10: ...0 Technical Specifications Design and specifications are subject to change without notice Model Power Supply AA BA BB BC BD CA DA EA EB EC 115V 60Hz 220V 230V 60Hz 230 208V 60Hz 200 220V 50Hz 220 240V 50Hz ...

Page 11: ... plug on the power cord of this appliance Follow national electrical codes or local codes and ordinances If the electric supply provided does not meet the above specifications call a licensed electrician Aluminum house wiring may pose special problems consult a qualified electrician This unit requires a separate circult serving only this appliance 115V 15 AMP Circuit parallel type 230V 208V 20 AMP...

Page 12: ...le circumstances it is advisable to install the sunshade to prevent the direct sunlight In this case take care not to cause any hindrance to the flow of outside air 3 When installing the air conditioner be sure to obtain sufficient space on the rear side of the unit for smooth flow of air When operating the air conditioner in closed areas such as inner building with cooling operation and result in...

Page 13: ...t grille It is secured in the section depending on the model In the case of an area where the drain pan can not be directly installed on the rear side of the unit after installing the air conditioner Example High storage In the case of an area where the drain pan can be directly installed on the rear side of the unit after installing the air conditioner 3 1 Press both sides of the cabinet in the d...

Page 14: ...IR CONDITIONER IS MANUFACTURED BY ESTE ACONDICIONADOR DE AIRE HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQUÉ PAR ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR QUESTO CONDIZIONATORE D ARIA È PRODOTTO DA ...

Reviews: