background image

E-

10

Installation (for 60Hz)

1     Electrical Requirements

For personal safety:

This appliance must be properly grounded.
Do not, under any circumstances, cut or remove the third grounding
prong from the power cord.
We recommend that you do not use an extension cord or an 
adapter plug with this appliance.
Do not change the plug on the power cord of this appliance.
Follow national electrical codes or local codes and ordinances.

If the electric supply provided does not meet the above
specifications, call a licensed electrician.
Aluminum house wiring may pose special problems-
consult a qualified electrician.
This unit requires a separate circult, serving only this appliance.

115V

15 AMP Circuit

"parallel" type

230V/208V

20 AMP circuit

"perpendicular" type

230V/208V

15AMP circuit

"tandem" type

230V/208V

30 AMP circuit

"tandem" type

Summary of Contents for AW07P1H Series

Page 1: ...A Ç N A R F DB98 26003A OWNER S INSTRUCTIONS E S F P I S Ê U G U T R O P O N A I L A T I DB98 20384A indd 23 2006 4 4 16 22 45 AW07P1H Series AW09P1H Series AW12P1H Series AWT12P1H Series AW14P1H Series AW18P1H Series AWT18P1H Series AW24P1H Series AWT24P1H Series AW122PM ...

Page 2: ...to its own specific power source which must be installed in compliance with national wiring earthing and safety regulations If the power cord is damaged in any way it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard This device must be installed according to the national electrical rules The appliance must be installation that the...

Page 3: ...ve adverse effects to the operation of other equipment under unfavorable mains conditions This equipment does not comply with the relevant technical standards for the limitation of voltage fluctuations and flicker Before connection this equipment to the power supply system please report to your suply authority and obtain the consent Do not connect other electric appliances to the same supply lines...

Page 4: ...wer plug may differ according to the type of local power supply Inner air flow blades right left orientation Outer air flow blades up down orientation Air inlet Outside Ventilation lever Power Cable Air inlet Inside The air filter is located in side Operating mode selection dial Temperature control dial Air flow blade swing switch Air Outlet Coolest ...

Page 5: ...W Low fan speed HI COOL MED COOL LOW COOL Result The air conditioner starts up in Cool mode The fan starts up at the speed selected You can change modes at any time 2 To adjust the temperature turn the temperature control dial to the desired position Possible temperatures Between 18 C and 29 C inclusive Result The air conditioner starts cooling if the room temperature is higher than the selected t...

Page 6: ... the operating mode selection dial to the OFF position Result Result The air inside the room circulates and stale air is evacuated outside Otherwise push the ventilation lever to the left and the closed position The air simply circulates inside the room Result The air conditioner starts up in Fan mode Result The air conditioner stops operating 2 Set the operating mode selection dial to the HI FAN ...

Page 7: ...ch to the off position when the blades are in the desired position Again depending on the position of the unit in your room you can adjust the orientation of the outer air flow blades on the right hand side of the unit RECOMMENDATION When Adjust the blades to face Cooling Upwards Adjust the air flow blades to the desired position by pushing them upwards or downwards Temperature and Humidity Ranges...

Page 8: ...lean the air conditioner Open the grille as much as possible 1 Grasp the lower part of the front grille and the front grille handle then open the grille The open angle of front grille has not to be exceeded 25 degree 2 Lift the front grille slightly and remove it from the front panel 3 Reassembling of front grille should be done in reverse order of disassembly If you Then Will not be using the air...

Page 9: ...t the circuit breaker used for the air conditioner has not been triggered Check that the power cable is plugged into a wall socket and the socket is switched on if necessary Check that the correct operating mode has been selected cooling or airing Check that the correct operating mode has been selected The room temperature may be too low Dust may be blocking the air filter refer to page 8 cleaning...

Page 10: ...nge the plug on the power cord of this appliance Follow national electrical codes or local codes and ordinances If the electric supply provided does not meet the above specifications call a licensed electrician Aluminum house wiring may pose special problems consult a qualified electrician This unit requires a separate circult serving only this appliance 115V 15 AMP Circuit parallel type 230V 208V...

Page 11: ...nces it is advisable to install the sunshade to prevent the direct sunlight In this case take care not to cause any hindrance to the flow of outside air 3 When installing the air conditioner be sure to obtain sufficient space on the rear side of the unit for smooth flow of air When operating the air conditioner in closed areas such as inner building with cooling operation and result in trouble wit...

Page 12: ...an and then re assemble it in the original condition 1 Follow steps 6 and 7 only 2 Remove the screw located at the lower section of the front grille It is secured in the section depending on the model In the case of an area where the drain pan can not be directly installed on the rear side of the unit after installing the air conditioner Example High storage In the case of an area where the drain ...

Page 13: ...682 3180 www samsung com latin REP DOMINICA 1 800 751 2676 www samsung com latin TRINIDAD TOBAGO 1 800 7267 864 www samsung com latin VENEZUELA 1 800 100 5303 www samsung com latin AUSTRALIA 1300 362 603 www samsung com au INDIA 3030 8282 1600 1100 11 www samsung com in INDONESIA 0800 112 8888 www samsung com id MALAYSIA 1800 88 9999 www samsung com my PHILIPPINES 1800 10 SAMSUNG 7267864 www samsu...

Reviews: