background image

Labor

1 Year  (In home)

Parts

1 Year 

Printed in Korea

YOUR SAMSUNG ROOM AIR CONDITIONER

WARRANTY

Limited Warranty to Original Purchaser

Samsung will repair or replace, at our option, this product if found defective within the warranty
period beginning from the original date of purchase. This Samsung Product is warranted by
SAMSUNG ELECTRONICS CANADA Inc. against manufacturing defects in materials or
workmanship for the period specified.

Limited 5-Years Compressor Warranty

Within one year of purchase Samsung Electronics Canada Inc. will provide a replacement
compressor if it is found to be defective in material or workmanship. During the existing four
years (second through fifth year) Samsung Electronics Canada Inc. will provide a replacement
only, without charge, if it is found to be defective in material or workmanship. Labor to install
the compressor during these existing four years is not included in the warranty. All warranty
repairs must be performed by a Samsung Authorized Service Centre.

Obligation of the Original Owner

The original dated purchase receipt must be retained as proof of purchase and presented to
the Authorized Service Centre before warranty services are rendered.

Exclusions of the Warranty

This warranty does not cover damage due to accident, fire, flood and/or other Acts of God:
misuse, incorrect line voltage, improper installation, improper or unauthorized repairs,
commercial use, or damages which occur in shipping. Exterior and interior finish and plastic
parts, are not covered under this warranty, Customer adjustments which are explained in the
instruction manual are not covered under the terms of this warranty. This warranty will
automatically be voided for any unit found with a missing or altered serial number.
This warranty is valid only on products purchased and used in Canada.

SAMSUNG ELECTRONICS CANADA INC.

55 Standish Court, Mississauga, Ontario L5R 4B2

Summary of Contents for AW 050BM

Page 1: ...DB98 17031A 5 AW0505M AW0595M Window type Room Air Conditioner Cool E F OWNER S INSTRUCTIONS AW050BM AW050DM ...

Page 2: ...power source which must be installed in compliance with national wiring earthing and safety regulations If the power cord is damaged in any way it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard This device must be installed according to the national electrical rules The appliance must be installation that the plug should be easi...

Page 3: ... Cooling Your Room 6 Ventilating Your Room 7 Switching the Air Conditioner Off 8 Adjusting the Air Flow Direction Horizontally 9 Adjusting the Air Flow Direction Vertically 9 RECOMMENDATIONS FOR USE Power Failure 10 Temperature and Humidity Ranges 10 Cleaning Your Air Conditioner 11 Solving Common Problems 12 Technical Specifications 13 E 3 ...

Page 4: ...Air inlet Inside Outer air flow blades up down orientation Except AW0505M AW0595M Power plug The type of power plug may differ depending on the local power supply Operating mode selection dial Thermostat control Ventilation lever Except AW0505M AW0595M Air outlet Air inlet Outside Air filter Inside AW050BM AW050DM AW050BMAW050DM ...

Page 5: ...your Owner s Instructions Your Owner s Instructions contain much valuable information on using your air conditioner Please take the time to read them as they will help you take full advantage of the unit s features The illustrations in the step by step procedures use four different symbols E 5 PRESS PUSH IMPORTANT NOTE ...

Page 6: ...up in cool mode You can change modes at any time Turn the THERMOSTAT control to the desired position You must select the COOL mode if you wish to adjust the Cooling temperature Fan speed when Cooling 1 2 Possible temperatures Can be set between 18 C and 29 C Result The air conditioner starts cooling if the room temperature is higher than the selected temperature E 6 ...

Page 7: ... fan turns rapidly The fan turns slowly You can change modes at any time 2 To control the direction of the air flow refer to page 9 3 If you wish to discharge stale air push the ventilation lever on the front of the unit to the right and open position Result The air inside the room circulates and stale air is discharged outside Otherwise push the ventilation lever to the left and closed position R...

Page 8: ...he Air Conditioner Off To switch the unit off simply set the operating mode selection dial to the position Result The air conditioner stops operating You can switch the air conditioner off whenever you want 1 E 8 ...

Page 9: ... Adjust the air flow blades to the desired position by pushing them upwards or downwards If you orient the air flow blades downwards and the unit operates in Cool mode for long periods of time dew may Form on the surface of the blades Drip from the blades E 9 Depending on the position of the unit in your room you can adjust the orientation of the inner air flow blades on the unit Adjust the air fl...

Page 10: ...Higher humidity levels Water may condense on and drip from the surface of the unit if it is used for long periods The following table indicates the temperature and humidity ranges within which the air conditioner can be used Mode Indoor Temperature Outdoor Temperature Indoor Humidity Cooling 21 C to 32 C approx 21 C to 43 C approx 80 or less If a power failure occurs the air conditioner is switche...

Page 11: ...o use benzene solvent or other chemical products 5 Be sure to clean the air filter periodically to maintain the air conditioner in the best condition for a long period of time When cleaning the air conditioner turn it off and pull out the power plug Set the fan going for a few hours to dry the inside of the air conditioner thoroughly If you Then Will not be using the air conditioner for a long per...

Page 12: ...hether there is any obstacle adversely affecting the flow of the air inside and outside the room Remove the obstacle or change the position of the air conditioner Check to see whether the air filter is clogged with dust or contaminated with foreign substances Clean the air filter Check to see whether there is any direct sunlight facing the air conditioner Block the sunlight with a sunshade Check t...

Page 13: ...Technical Specifications Model Power Supply AW0505M AW0595M Design and specifications are subject to change without notice 115V 60Hz E 13 AW050BM AW050DM ...

Page 14: ...ompressor during these existing four years is not included in the warranty All warranty repairs must be performed by a Samsung Authorized Service Centre Obligation of the Original Owner The original dated purchase receipt must be retained as proof of purchase and presented to the Authorized Service Centre before warranty services are rendered Exclusions of the Warranty This warranty does not cover...