background image

30_

cleaning and maintaining

cleaning and maintaining the 

air conditioner

MAINTAINING YOUR AIR CONDITIONER

If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in 
best condition. 

1. 

Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect 
the power plug. There may be internal damage if moisture is left in components.

2. 

Before using the air conditioner again, dry the inner components of the air conditioner again 
by running in Fan mode for 3 to 4 hours. This helps remove odors which may have generated 
from dampness. 

Periodical checks 

Refer to the following chart to maintain the air conditioner properly.

Type

Description

Every 2 

weeks

Every 3 

months

Every 4 

months

Once a 

year

Indoor unit

Clean the air filter (1)

Clean the bio filter (1)

Replace the deodorizing filter (1)

Clean the condensate drain pan (2)

Thoroughly clean the heat exchanger (2)

Clean the condensate drain pipe (2)

Replace the remote control batteries (1)



Outdoor unit

Clean the heat exchanger on the outside 

of the unit (2)

Clean the heat exchanger on the inside 

of the unit (2)

Clean the electric components with jets 

of air (2)

Verify that all the electric components are 

firmly tightened (2)

Clean the fan (2)

Verify that all the fan assembly is firmly  

tightened (2)

Clean the condensate drain pan (2)



:  This check mark requires checking the indoor/outdoor unit periodically, following to the 

description to maintain the air conditioner properly.

The checks and maintenance operations described are essential to guarantee the 
efficiency of the air conditioner. The frequency of these operations varies according to the 
characteristics of the area, the amount of dust, etc.
(1)  The described operations should be performed more frequently if the area of installation 

is very dusty.

(2)  These operations must always be performed by qualified personnel. For more detailed 

information, see the Installation Manual.

Summary of Contents for AVXWVH071EE

Page 1: ...rovides maximum cooling power in the summer but also can be an efficient heating method in the winter with the advanced Heat pump system Heat pump system is 3 times more efficient compare to the other...

Page 2: ...help and information online at www samsung com Important safety symbols and precautions WARNING Hazards or unsafe practices that may result in severe personal injury or death CAUTION Hazards or unsaf...

Page 3: ...damaged or dusted power plug power cable or loosened power receptacle Potential risk of fire or electric shock Install an exclusive circuit breaker and short circuit breaker for the air conditioner P...

Page 4: ...measures to prevent the allowable concentration from being exceeded If the refrigerant leaks and cause the concentration limit to be exceeded hazards due to lack of oxygen in the room may result If th...

Page 5: ...l risk of malfunction electric shock or fire if repairs or installations are attempted by a non qualified service technician Do not spray flammable gases such as insecticide near the air conditioner P...

Page 6: ...disabled people The packaging material and used batteries of the remote controller optional must be disposed of in accordance with the national standards The refrigerant used in the air conditioner m...

Page 7: ...ability to perform routine maintenance and repairs The units components must be accessible and that can be disassembled in conditions of complete safety either for people or things For this reason wh...

Page 8: ...Vertical air flow 19 Horizontal air flow This product has been determined to be in compliance with the Low Voltage Directive 2006 95 EC and the Electromagnetic Compatibility Directive 2004 108 EEC of...

Page 9: ...UNIT AND DISPLAY Carefully unpack your air conditioner and check the indoor unit to make sure it is not damaged Main parts Display Your air conditioner may slightly look different from illustration sh...

Page 10: ...front panel is open you can check the room temperature sensor You can turn on the air conditioner without the remote control by pressing the Power button The room temperature sensor measures indoor ro...

Page 11: ...operating modes see pages 14 18 for instructions Fan Adjust how much air flows through the air conditioner with the 5 different fan speeds such as Auto Silence Low Medium High Air swing Activate Deact...

Page 12: ...est contact center Inserting the batteries Correct disposal of batteries in this product Applicable in the European Union and other European countries with separate battery return systems This marking...

Page 13: ...er button on the remote control 2 Set the operating mode Press the Mode button on the remote control until Auto mode and Auto fan speed indicator appear on the remote control display The air condition...

Page 14: ...can set the desired temperature between the range of 16 C 30 C You can increase decrease the temperature by 1 C 4 Set the fan speed Press the Fan or button on the remote control to set the desired fa...

Page 15: ...display The air conditioner operates in Dry mode and automatically adjust the fan speed to Auto Each time you press the Mode button the mode will change in order of Auto Cool Dry Fan and Heat 3 Set t...

Page 16: ...air conditioner operates in Fan mode and circulate the indoor air Each time you press the Mode button the mode will change in order of Auto Cool Dry Fan and Heat 3 Set the fan speed Press the Fan or...

Page 17: ...the range of 16 C 30 C You can increase decrease the temperature by 1 C 4 Set the fan speed Press the Fan or button on the remote control to set the desired fan speed If room temperature reaches desi...

Page 18: ...ress the Air swing button on the remote control again to keep the air flow direction in a constant position Horizontal air flow Make sure one of the blade pin lever that stick out of the air flow blad...

Page 19: ...0 minutes and then operates in last used mode or in Auto mode if Dry Fan mode is most recent mode used Turbo function is only available in Auto Cool Heat mode If Turbo function is selected in Dry Fan...

Page 20: ...control display will show the hour s you have set for 3 seconds and set desired temperature will display The air conditioner will operate automatically at set time and then On timer indicator stops bl...

Page 21: ...display will show the hour s you have set for 3 seconds and set desired temperature will display The air conditioner will operate automatically at set time and then Off timer indicator stops blinking...

Page 22: ...the preset time of the On Timer is 3 hours and the Off Timer is 5 hours the air conditioner will turn on after 3 hours from the moment you have set the timer Your air conditioner will remain on for 2...

Page 23: ...control to change the time setting while Off timer indicator is blinking You can set the time up to 12 hours increasing in 30 minute unit up to first 3 hours and in hourly unit after first 3 hours 4...

Page 24: ...he temperature Sound sleep Relaxes your body and raises your temperature slightly Wake up from mode Allows you to wake up from comfortable intermittent air and it makes you feel refresh Set Off timer...

Page 25: ...art Saver function is only available in Cool mode When Smart Saver function is activated temperature range will be limited to 24 C 30 C If the desired temperature is lower than 24 C turn off the Smart...

Page 26: ...ure to unplug the power from the unit No special tools are needed to clean it Air filter Washable foam based air filter captures large particles from the air The filter is cleaned with a vacuum or by...

Page 27: ...ed over the hooks of the unit 2 Remove the Air filter Grab the handle and lift it up Then pull the Air filter towards you and slide it down 3 Slide the Bio filter sky blue out to remove it from the sl...

Page 28: ...ightly push the panel up until the panel is hanged over the hooks of the unit 2 Remove the Air filter Grab the handle and lift it up Then pull the Air filter towards you and slide it down 3 Slide the...

Page 29: ...e condensate drain pan 2 Thoroughly clean the heat exchanger 2 Clean the condensate drain pipe 2 Replace the remote control batteries 1 Outdoor unit Clean the heat exchanger on the outside of the unit...

Page 30: ...eat pump is heating Anti protection of internal battery The compressor will be off to protect internal battery when the air conditioner operates in Cool mode Protect compressor The air conditioner doe...

Page 31: ...or Dry mode The air conditioner automatically adjusts the fan speed to Auto in Auto Dry mode Timer function does not set Check if you press the Set Cancel button on the remote control after you have...

Page 32: ...drops on the floor 18 24 10 C to 43 C HEATING 27 C or less 09 12 10 C to 24 C Internal protection triggers and the air conditioner will stop 18 24 15 C to 24 C DRYING 16 C to 32 C 09 12 10 C to 43 C C...

Page 33: ...u NETHERLANDS 0900 SAMSUNG 0900 7267864 0 10 Min www samsung com nl NORWAY 3 SAMSUNG 7267864 www samsung com no POLAND 0 801 1SAMSUNG 172678 022 607 93 33 www samsung com pl PORTUGAL 80820 SAMSUNG 726...

Page 34: ...bilities Thank you for purchasing this Samsung product To receive more complete service please register your product at www samsung com global register AQV09U Series AQV12U Series AQV18U Series AQV24U...