Samsung AVXC2H056EE Service Manual Download Page 444

PCB Diagram and Parts List

6-97

Samsung Electronics

ASS'Y PCB MAIN MCU : DB9304661G 

(cont.)

CN64 3711-000996 

CONNECTOR-HEADER  BOX,5P,1R,2.5mm,STRAIGHT,SN,BLK 

SNA 

1

CN66 3711-000997 

CONNECTOR-HEADER  BOX,5P,1R,2.5mm,STRAIGHT,SN,BLU 

SNA 

1

CN65 3711-000998 

CONNECTOR-HEADER  BOX,5P,1R,2.5MM,STRAIGHT,SN,RED 

SNA 

1

CN63 3711-000999 

HEADER-BOARD 

TO 

CABLE 

BOX,5P,1R,2.5mm,STRAIGHT,SN,WHT 

SNA 

1

CN67 3711-001000 

HEADER-BOARD 

TO 

CABLE 

BOX,5P,1R,2.5mm,STRAIGHT,SN,YEL 

SNA 

1

CN62 3711-001036 

HEADER-BOARD 

TO 

CABLE 

BOX,6P,1R,2.5mm,STRAIGHT,SN,BLU 

SNA 

1

CN71 3711-003404 

HEADER-BOARD 

TO 

CABLE 

1WALL,2P,1R,7.92mm,STRAIGHT,SN,BLU 

SNA 

1

CN10 3711-005716 

HEADER-BOARD 

TO 

CABLE 

BOX,10P,1R,2mm,STRAIGHT,SN,BLK 

SNA 

1

CN10_SUB 3711-005716 

HEADER-BOARD 

TO 

CABLE  BOX,10P,1R,2mm,STRAIGHT,SN,BLK 

SNA  1

DIS1 

DB07-00054A 

LED DISPLAY 

SSD-A3202GS-A13,LED DISPLAY,2 DIGIT,16 SEGMENT,2  

SNA 

  

 

 

DIGIT,16.6x16x13mm,GREEN,50mW,9 

DIS2 

DB07-00054A 

LED DISPLAY 

SSD-A3202GS-A13,LED DISPLAY,2 DIGIT,16 SEGMENT,2  

SNA 

  

 

 

DIGIT,16.6x16x13mm,GREEN,50mW,9 

ST11 DB26-00015A 

TRANS 

SWITCHING 

-,JT1916-09,-,310V,FERRITE,-,EI1916,130KHZ,-,1.65MH,-,-,-,-, 

SNA 

1

  

 

 

SHIELD 

FT71 

DB27-00019A 

COIL CHOKE 

SSC1905200B,Line Filter,20mH,+50%,-30%,-,0.3ohm,2.5A, 

SNA 

1

  

 

 

20*28 

mm,-,13*18,-,-,-,-25 

PCB 

DB41-00450A 

PCB MAIN-OUT 

HR2,DVM PLUS3 MCU,FR-4,2,T1.6,1,MCU 

SNA 

1

HEAT-SINK2 

DB62-03581B 

HEAT SINK 

DPM,A6063,T1.3,W15,L15,WHT,HEIGHT : 40 

SNA 

1

VA-CAP DB67-00963A 

CAP-VARISTOR 

VERDI-PJT,SHP2,1.0,11.5,14.5,BLUE,DDIA-2, 

105degree,600V 

SNA 

1

C04 

DB91-00648F 

ASSY-MIC 

PLUS3 MCU (DVM PLUS4 HR MCU) Micom,STM-0829-FS,  

SNA 

1

 

  

 

MB90F823, 80QFP, ROM 128KB 

IC05 

DB91-00654A 

ASSY-MIC 

PLUS3 MCU sub Micom,STM-0834-OS, MB90F823,  

SNA 

1

 

  

 

ROM 128K bytes 

Location No.

Code No.

Description

Specification

SA/SNA

Remark

$9;&6+B$BaLQGG

Summary of Contents for AVXC2H056EE

Page 1: ...VXTFH056 071EE ND056 071CHXEA XSE AVXTJH028 036 056EE ND028 036 056JHXEA XSE AVXWBH028 036 056 071EE ND028 036 056 071BHXEA XSE AVXWNH022 028 036 056 071EE ND022 028 036 056 071NHXEA XSE ND022 028 036 045 056 071QHXEA AVXWVH022 028 036 056 071EE ND022 028 036 056 071VHXEA XSE ND0561 0711HXEH ND022 028 036 045 056 071QHXEB ND022 028 036 045 056 071QHXEBSTK OUTDOORUNIT RD080 100 120 140 160 180 200H...

Page 2: ...t Specifacations 2 10 2 2 1 Indoor Unit 2 10 2 2 2 Outdoor Unit 2 31 2 3 Accessory and Option Specifications 2 35 2 3 1 Accessories 2 35 3 Disassembly and Reassembly 3 1 3 1 Indoor Unit 3 2 3 2 Outdoor Unit 3 23 3 3 MCU 3 41 3 4 EEV KIT 3 42 4 Troubleshooting 4 1 4 1 Check up Window Description 4 1 4 2 Troubleshooting 4 2 4 2 1 Setting Option Setup Method 4 2 4 2 2 What to check before diagnosis 4...

Page 3: ...king 4 81 4 5 23 Communication error between main and sub Micom of outdoor unit or between outdoor units 4 82 4 5 24 Communication Error between MCU and Outdoor Unit 4 83 4 5 25 Communication Error between MAIN HUB PBA 4 84 4 5 26 Communication Error between MCU and Outdoor Unit afterTracking is Completed 4 85 4 5 27 MCU branch part setup error inconsecutive connection with the use of 2 branch par...

Page 4: ... Valve oil balance valve 1 Self diagnosis Open Close error Breakaway or Fault of Sensor 4 119 4 5 61 EVI EEV Open Error 4 120 4 5 62 Refrigerant Leakage Error 4 121 4 5 63 Prohibition of the operation of Compressor due to OoutdoorTemperature 4 122 4 5 64 High Pressure Standard Not Met before Air Conditioning Inability to Re operate 4 123 4 5 65 CCH Malfunction and Sump Sensor Miswiring Error 4 124...

Page 5: ...2 3 RD140HHXGA 5 79 5 2 4 RD140HHXGB RD140HHXGASTK 5 83 5 2 5 RD160HHXGA RD180HHXGA RD200HHXGA 5 87 5 2 6 RD160 180 RD200HHXGB RD160 180 200HHXGASTK 5 91 5 2 7 RD080 100 120HRXGA 5 95 5 2 8 RD080 100 120HRXGB RD080 100 120HRXGASTK 5 99 5 2 9 RD140HRXGA 5 103 5 2 10 RD140HRXGB RD140HRXGASTK 5 107 5 2 11 RD160 180 200HRXGA 5 111 5 2 12 RD160 180 200HRXGB RD160 180 200HRXGASTK 5 115 5 2 13 MCU 4EAE3 ...

Page 6: ...B MAIN HUB DB93 11209A B 6 65 6 3 3 ASS Y PCB SUB DRIVER 6 77 6 3 4 ASS Y PCB SUB SENSOR CT UP DB93 11518A 6 86 6 3 5 ASS Y PCB SUB SENSOR CT LOW DB93 11519A 6 89 6 3 6 ASS Y PCB MAIN MCU DB93 04661G 6 90 7 Wiring Diagram 7 1 7 1 Indoor 7 1 7 1 1 Slim 1way cassette type 7 1 7 1 2 2way cassette type 7 3 7 1 3 4way cassette type 7 4 7 1 4 Mini 4way cassette type 7 5 7 1 5 DUCT type Slim I II 7 6 7 1...

Page 7: ... 17 8 2 Outdoor Unit 8 18 8 2 1 ASS Y PCB MAIN 8 18 8 2 2 ASS Y PCB MAIN HUB 8 19 8 2 3 ASS Y PCB SUB DRIVER 8 20 8 2 4 ASS Y PCB SUB SENSOR CT UP 8 22 8 2 5 ASS Y PCB SUB SENSOR CT LOW 8 23 9 Reference Sheet 9 1 9 1 Index for Model Name 9 1 9 1 1 Indoor Unit 9 1 9 1 2 Outdoor Unit 9 3 9 2 Refrigerant Circuit Diagram 9 5 9 2 1 Cycle Operation Mode 9 5 9 3 Pump down Method 9 18 9 3 1 Precautions fo...

Page 8: ...ctricity Please wear insulation gloves before performing PCB repair and measurement O Check if the place of installation is at least 2m away from electronic appliances such as TV video players and stereos This can cause irregular noise or degrade the picture quality O Please make sure the customer does not directly repair the product Arbitrary dismantling may result in electric shock or fire 1 3 P...

Page 9: ...r to workers O Please remove the oxide produced inside the pipe during the welding with nitrogen gas Using another gas may cause harm to the product or others 1 6 Precautions for Additional Supplement of Air Conditioner Refrigerant O Precisely calculate the refrigerant by using a scale and S net and proceed with the test operation Excessive supplement can cause harm to the product since it can cau...

Page 10: ...ear capacity control Installation nature Maximum capacity 80HP Longest pipe 220m Maximum elevation 110m Reduced installation floor area Cooling Heating Achieves world class efficiency Full line up average COP 3 98 Over 90 stable operation at low temp operating condition if 10 C 90 n 55 10 C Low temp Outside Air Q Stronger DVM PLUS 4 Achieves world class efficiency with hyper compressor that applies...

Page 11: ...nditioning and heating with excellent energy efficiency Q Hyper Compressor Q New Concept Plate type Inter cooler Medium pressure refrigerant inlet Low pressure refrigerant outlet Medium pressure refrigerant outlet High pressurerefrigerantoutlet Increased cooling effect due to plate type inter cooler New Concept PHE Inter cooler Plate Heat Exchanger Air Conditioning Efficiency 12 Heating Efficiency 19 9...

Page 12: ...Fin New Φ7 Wide Width Fin Heat Exchange Amount 15 New Φ8 G Fin Heat Exchange Amount 10 10 100 Linear capacity control efficiency with variable scroll compression operation for PWM control Linear capacity variable for every field 10 100 step 1 Increase in refrigerant circulation with vapor injection step 2 Low pressure refrigerant outlet Low pressure refrigerant outlet Compressor operating rate Int...

Page 13: ...220m Elevation 110m Total Pipe Length 1km Possible to connect a maximum of 80HP Maximum of 30 decrease in installation area Longest Pipe Length 220m Elevation between Indoor and Outdoor Units 110m Elevation between Indoor Units 15m Total Pipe Length 1000m Longest Pipe Length after First Air Conditioning 90m 9 6 B B a LQGG ...

Page 14: ...Product Specifications Samsung Electronics 2 5 Feature cont Q Smallest Footprint Area 26 reduction compared to existing 2 module compounded model Outdoor Unit Floor Area 1 34 m 0 99 m 26 9 6 B B a LQGG ...

Page 15: ...Improves heat exchanger efficiency and overall optimiza tion New G Fin Highly efficient new G Fin increased heat transfer performance reinforced corrosion resistance and increased operating duration in frost condition Ø7 2 rows 60 columns FP1 5 Ø7 2 rows 60 columns FP1 5 Ø8 2 rows 60 columns FP1 8 Ø7 3 rows 60 columns FP1 7 Ø8 3 rows 60 columns FP1 8 Changed part ChangedItem andfeature Basic After...

Page 16: ...cting wires improved reliability Installation method for relay station has changed Installed inside power box Changed part ChangedItem andfeature Basic Afterchanged Main PBA Main PBA has changed Separation between load use and control use Optional resistance for each model has been removed Standardization Downloading options are required to change PBA Hub PBA New Hub PBA Separation between load us...

Page 17: ... CT sensor Changed part Changed model ChangedItem andfeature Basic Afterchanged ASS Y PIPE RD080HHXG RD100HHXG RD120HHXG RD140HHXG RD160HHXG RD180HHXG RD200HHXG RD080HRXG RD100HRXG RD120HRXG RD140HRXG RD160HRXG RD180HRXG RD200HRXG Pipe Optimization o Reduced pressure loss o Improved efficiency Service ability improvement o Working space is secured by positioning all pipes hidden by C BOX to the si...

Page 18: ...Product Specifications Samsung Electronics 2 9 Q Position of changing parts C BOX COVER TOP FAN PBA ASS Y PIPE HEAT EXCHANGER CONTROL IN FRONT CABI COVER VALVE 9 6 B B a LQGG ...

Page 19: ...g High m3 min 7 57 5 8 64 5 9 73 5 Refrigerant Type R410A R410A R410A Control Method EEV EEV EEV Temperature Control Micom Thermistors Micom Thermistors Micom Thermistors Safety Devices Fuse Fuse Fuse Piping Connections Liquid Flare ø mm 6 35 6 35 6 35 Gas Flare ø mm 12 7 12 7 12 7 Drain Quick Lock ø mm VP20 OD 25 ID 20 VP20 OD 25 ID 20 VP20 OD 25 ID 20 Weight NetWeight kg 10 5 10 5 10 5 ShippingW...

Page 20: ...t W 54 54 Airflow Rate Cooling High m3 min 15 0 16 5 Heating High m3 min Refrigerant Type R410A R410A Control Method EEV EEV Temperature Control Micom Thermistors Micom Thermistors Safety Devices Fuse Fuse Piping Connections Liquid Flare ø mm 6 35 9 52 Gas Flare ø mm 12 7 15 88 Drain Quick Lock ø mm VP25 OD 32 ID 25 VP25 OD 32 ID 25 Weight NetWeight kg 14 5 14 5 ShippingWeight kg 18 5 18 5 Dimensi...

Page 21: ...ate Cooling High m3 min 14 14 Heating High m3 min 16 16 Refrigerant Type R410A R410A Control Method EEV EEV Temperature Control Micom Thermistors Micom Thermistors Safety Devices Fuse Fuse Piping Connections Liquid Flare ø mm 6 35 9 52 Gas Flare ø mm 12 70 15 88 Drain Quick Lock ø mm VP25 OD 32 ID 25 VP25 OD 32 ID 25 Weight NetWeight kg 21 0 21 0 ShippingWeight kg 25 0 25 0 Dimensions Net Dimensio...

Page 22: ...0x926 Panel Size Model P4SMA P4SMA P4SMA P4SMA NetWeight kg 7 0 7 0 7 0 7 0 ShippingWeight kg 10 3 10 3 10 3 10 3 Net Dimensions W x H x D mm 950x35x950 950x35x950 950x35x950 950x35x950 Shipping Dimensions W x H x D mm 1 042x103x1 042 1 042x103x1 042 1 042x103x1 042 1 042x103x1 042 Functions Auto Restart O O O O Auto Swing O O O O Group Individual Control O O O O External Contact Control O O O O T...

Page 23: ...ight kg 7 0 7 0 7 0 ShippingWeight kg 10 3 10 3 10 3 Net Dimensions W x H x D mm 950x35x950 950x35x950 950x35x950 Shipping Dimensions W x H x D mm 1 042x103x1 042 1 042x103x1 042 1 042x103x1 042 Functions Auto Restart O O O Auto Swing O O O Group Individual Control O O O External Contact Control O O O Trouble Shooting by LED O O O Standard Accessories Installation Manual O O O Operation Manual X X...

Page 24: ...MA P4SMA NetWeight kg 7 0 7 0 7 0 7 0 ShippingWeight kg 10 3 10 3 10 3 10 3 Net Dimensions W x H x D mm 950x35x950 950x35x950 950x35x950 950x35x950 Shipping Dimensions W x H x D mm 1 042x103x1 042 1 042x103x1 042 1 042x103x1 042 1 042x103x1 042 Functions Auto Restart O O O O Auto Swing O O O O Group Individual Control O O O O External Contact Control O O O O Trouble Shooting by LED O O O O Standar...

Page 25: ...ShippingWeight kg 10 3 10 3 10 3 Net Dimensions W x H x D mm 950x35x950 950x35x950 950x35x950 Shipping Dimensions W x H x D mm 1 042x103x1 042 1 042x103x1 042 1 042x103x1 042 Functions Auto Restart O O O Auto Swing O O O Group Individual Control O O O External Contact Control O O O Trouble Shooting by LED O O O Standard Accessories Installation Manual O O O Operation Manual X X X Pattern Sheet for...

Page 26: ...x635 660x310x635 660x310x635 660x310x635 Panel Size Model PMSMA PMSMA PMSMA PMSMA NetWeight kg 3 5 3 5 3 5 3 5 ShippingWeight kg 6 2 6 2 6 2 6 2 Net Dimensions W x H x D mm 670x35x670 670x35x670 670x35x670 670x35x670 Shipping Dimensions W x H x D mm 717x93x717 717x93x717 717x93x717 717x93x717 Functions Auto Restart O O O O Auto Swing O O O O Group Individual Control O O O O External Contact Contro...

Page 27: ...39 0 39 0 Dimensions Net Dimensions W x H x D mm 900x199x600 900x199x600 900x199x600 1 100x199x600 1 100x199x600 Shipping Dimensions W x H x D mm 1 133x330x730 1 133x330x730 1 133x330x730 1 330x330x730 1 330x330x730 Functions Auto Restart O O O O O Auto Swing X X X X X Group Individual Control O O O O O External Contact Control O O O O O Trouble Shooting by LED X X X X X Standard Accessories Insta...

Page 28: ... 54 5 Dimensions Net Dimensions W x H x D mm 1 100x199x600 1 300x295x690 1 300x295x690 1 300x295x690 1 300x295x690 Shipping Dimensions W x H x D mm 1 330x330x730 1 600x444x831 1 600x444x831 1 600x444x831 1 600x444x831 Functions Auto Restart O O O O O Auto Swing X X X X X Group Individual Control O O O O O External Contact Control O O O O O Trouble Shooting by LED X X X X X Standard Accessories Ins...

Page 29: ...39 0 52 0 52 0 ShippingWeight kg 36 36 41 46 0 60 0 60 0 Dimensions Net Dimensions W x H x D mm 900x260x480 900x260x480 1 150x260x480 1 150x320x480 1 200x360x650 1 200x360x650 Shipping Dimensions W x H x D mm 1 146x363x584 1 146x363x584 1 390x345x574 1 396x424x584 1 447x425x769 1 447x425x769 Functions Auto Restart O O O O O O Auto Swing X X X X X X Group Individual Control O O O O O O External Con...

Page 30: ...p Individual Control O External Contact Control O Trouble Shooting by LED X Standard Accessories Installation Manual O Operation Manual O Pattern Sheet for Installation X Flexible Drain Hose O Filter Safety Grille Filter Washable Optional Accessories Wireless Remote Controller MR BH01 Duct Receiver Kits Receiver MRK A01 ReceiverWire MRW 10A Wired Remote Controller Simplified MWR SH00 Standard MWR ...

Page 31: ...x812 Functions Auto Restart O Auto change over O Auto Swing X Group Individual Control O External Contact Control O Trouble Shooting by LED X Standard Accessories Installation Manual O Operation Manual O Pattern Sheet for Installation X Flexible Drain Hose X Filter Safety Grille Filter Washable Drain Pump Pumping speed lift Wireless Remote Controller Optional Accessories Wireless Remote Controller...

Page 32: ...0x470x1 040 1 240x470x1 040 Shipping Dimensions W x H x D mm 1 507x558x1 155 1 507x558x1 155 1 507x558x1 155 Functions Auto Restart O O O Auto Swing X X X Group Individual Control O O O External Contact Control O O O Trouble Shooting by LED X X X Standard Accessories Installation Manual O O O Operation Manual O O O Pattern Sheet for Installation O O O Flexible Drain Hose O O O Filter Safety Grille...

Page 33: ...00 1 100x199x600 Shipping Dimensions W x H x D mm 1 330x330x730 1 330x330x730 Functions Auto Restart O O Auto Swing X X Group Individual Control O O External Contact Control O O Trouble Shooting by LED X X Standard Accessories Installation Manual O O Operation Manual O O Pattern Sheet for Installation X X Flexible Drain Hose O O Filter Safety Grille Filter Washable Filter Washable Optional Accesso...

Page 34: ...x620x199 720x620x199 720x620x199 Shipping Dimensions W x H x D mm 810x710x295 810x710x295 810x710x295 Functions Auto Restart O O O Auto Swing O O O Group Individual Control O O O External Contact Control O O O Trouble Shooting by LED O O O Standard Accessories Installation Manual O O O Operation Manual O O O Pattern Sheet for Installation X X X Flexible Drain Hose O O O Filter Safety Grille Filter...

Page 35: ... 16 5 Dimensions Net Dimensions W x H x D mm 900x304x185 900x304x185 1 100x307x225 1 100x307x225 Shipping Dimensions W x H x D mm 963x349x247 963x349x247 1157x381x292 1157x381x292 Functions Auto Restart O O O O Auto Swing O O O O Group Individual Control O O O O External Contact Control O O O O Trouble Shooting by LED O O O O Standard Accessories Installation Manual O O O O Operation Manual O O O ...

Page 36: ...eight kg 11 5 5 11 5 5 11 5 5 15 0 5 15 0 5 Dimensions Net Dimensions W x H x D mm 825x285x189 825x285x189 825x285x189 1 099x315x217 1 099x315x217 Shipping Dimensions W x H x D mm 900x349x252 900x349x252 900x349x252 1 137x377x299 1 137x377x299 Functions Auto Restart O O O O O Auto Swing O O O O O Group Individual Control O O O O O External Contact Control O O O O O Trouble Shooting by LED O O O O ...

Page 37: ...89 Shipping Dimensions W x H x D mm 900x349x252 900x349x252 900x349x252 Functions Auto Restart O O O Auto Swing O O O Group Individual Control O O O External Contact Control O O O Trouble Shooting by LED O O O Standard Accessories Installation Manual O O O Operation Manual O O O Pattern Sheet for Installation X X X Flexible Drain Hose O O O Filter Safety Grille Filter Washable Filter Washable Filt...

Page 38: ...17 Shipping Dimensions W x H x D mm 1 137x377x299 1 137x377x299 1 137x377x299 Functions Auto Restart O O O Auto Swing O O O Group Individual Control O O O External Contact Control O O O Trouble Shooting by LED O O O Standard Accessories Installation Manual O O O Operation Manual O O O Pattern Sheet for Installation X X X Flexible Drain Hose O O O Filter Safety Grille Filter Washable Filter Washabl...

Page 39: ... ShippingWeight kg 11 5 11 5 11 5 15 15 Dimensions Net Dimensions W x H x D mm 825x285x189 825x285x189 825x285x189 1 065x298x218 1 065x298x218 Shipping Dimensions W x H x D mm 900x349x252 900x349x252 900x349x252 1 137x377x299 1 137x377x299 Functions Auto Restart O O O O O Auto Swing O O O O O Group Individual Control O O O O O External Contact Control O O O O O Trouble Shooting by LED O O O O O St...

Page 40: ... Output kW 4 36 4 36 4 36 4 36 5 87 5 87 4 36 4 36 4 36 4 36 5 87 5 87 Lubricant Type 3MAF POE 3MAF POE 3MAF POE 3MAF POE 3MAF POE 3MAF POE Charging cc 4 370 4 370 4 370 3 370 3 370 3 370 Refrigerant Type R410A R410A R410A R410A R410A R410A Factory Charging kg 5 0 5 0 5 0 7 5 7 5 7 5 FAN Type Control Propeller BLDC Propeller BLDC Propeller BLDC Propeller BLDC Propeller BLDC Propeller BLDC Motor Ou...

Page 41: ...5 87 5 87 5 16 5 16 X 2 5 87 5 87 X 2 5 87 5 87 X 2 5 16 4 36 X 2 5 16 5 16 X 2 Lubricant Type 3MAF POE 3MAF POE 3MAF POE 3MAF POE 3MAF POE 3MAF POE Charging cc 4 370 6 540 6 540 6 540 5055 5055 Refrigerant Type R410A R410A R410A R410A R410A R410A Factory Charging kg 7 0 7 0 8 5 8 5 11 0 11 0 FAN Type Control Propeller BLDC Propeller BLDC Propeller BLDC Propeller BLDC Propeller BLDC Propeller BLDC...

Page 42: ...6 5 87 5 87 4 36 4 36 4 36 4 36 5 87 5 87 Lubricant Type 3MAF POE 3MAF POE 3MAF POE 3MAF POE 3MAF POE 3MAF POE Charging cc 4 370 4 370 4 370 3 370 3 370 3 370 Refrigerant Type R410A R410A R410A R410A R410A R410A Factory Charging kg 5 0 5 0 5 0 7 5 7 5 7 5 FAN Type Control Propeller BLDC Propeller BLDC Propeller BLDC Propeller BLDC Propeller BLDC Propeller BLDC Motor Output W 630 630 630 630 630 63...

Page 43: ... 5 87 5 87 X 2 5 16 4 36 X 2 5 16 5 16 X 2 Lubricant Type 3MAF POE 3MAF POE 3MAF POE 3MAF POE 3MAF POE 3MAF POE Charging cc 4 370 6 540 6 540 6 540 5055 5055 Refrigerant Type R410A R410A R410A R410A R410A R410A Factory Charging kg 7 0 7 0 8 5 8 5 11 0 11 0 FAN Type Control Propeller BLDC Propeller BLDC Propeller BLDC Propeller BLDC Propeller BLDC Propeller BLDC Motor Output W 630 X 2 630 X 2 630 X...

Page 44: ...assette panel P2SMA AVXC2H666 Series 4 way cassette panel P4SMA AVXC4H666 Series ND6664H666 Series mini 4 way cassette panel PMSMA AVXCMH666 Series Drain Pump MDP E075SEE AVXDSH022 071E6 Series AVXTHF056E6 Series ND056CH6 Series MDP E075SEE1 AVXDSH090 140E6 Series AVXTHF071E6 Series ND071CH6 Series MDP E075SEE3 ND022 140L6 Series MDP M075SGU1 AVXDUH071 112E6 Series ND071 112SH6 Series MDP M075SGU2...

Page 45: ... 139 2kW MXJ YA4422S over 139 2kW Y Joint only HR MXJ YA1500S below 23 2kW MXJ YA2500S 23 2 69 6kW MXJ YA3100S 69 6 139 2kW MXJ YA3800S over 139 2kW Outdoor Joint MXJ T3819S below 48 HP MXJ T4422S over 50 HP Outdoor Joint only HR MXJ T3100S below 48 HP MXJ T3800S over 50 HP Header Joint MXJ HA2512S below 46 4kW for 4 rooms MXJ HA3115S below 69 6kW for 8 rooms MXJ HA3819S over 69 6kW for 8 rooms AV...

Page 46: ...unit MXD A13K200E up to 3 6kW possible with 2 unit MXD A16K200E up to 5 6kW possible with 2 unit 3 Room EEV Kit MXD A13K216E up to 3 6kW possible with 2 unit over 5 6 kW possible with 1 unit MXD A13K300E up to 3 6kW possible with 3 unit MXD A16K213E up to 3 6kW possible with 1 unit over 5 6 kW possible with 2 unit MXD A16K300E over 5 6 kW possible with 3 unit Wireless Signal Receiver Kit MRK A00 O...

Page 47: ...0 Option MWR SH00 Option 7 day Scheduler MWR BS00 Option 485 Interface Module MIM B13A Option Ket Tag Interface Module MIM B02 Option Lonworks Interface Module MIM B07 Option External Contact Interface Module MIM B14 Option SIM Interface Module MIM B12 Option Centralized Controller MCM A202A Option AVXCSH022_33425A 2 _1 4 indd 38 2011 09 07 11 50 38 ...

Page 48: ...cessories cont Item Descriptions Code No Q TY Remark Function Controller MCM A100 Option Operation Selection Switch MCM C200 Option DMS MIM D00 Option S NET 3 MST P3P Option S NET mini MST S3W Option AVXCSH022_33425A 2 _1 4 indd 39 2011 09 07 11 50 38 ...

Page 49: ...ies AIXCSH666 2 way cassette AVXC2H666 Series AVXC2H071EA 4 way cassette AVXC4H666 Series ND6664H666 Series AIXC4H666 mini 4 way cassette AVXCMH666 Series AVXCMH666EA SLIM DUCT AVXDSH666Series ND666L6 Series EH666EAV EH666EZMC MSP DUCT AVXDUH666 Series ND666SH666 Series DH666EAMC HSP DUCT ND666H6 Series AVXDUH666 SUPER DUCT AVXDUH666 Series DC666GTSA CEILING AVXTFH666 Series ND666CH666 Series FH66...

Page 50: ...open it 2 Separate 1 clip from the Panel and tilt the Grill to 45 and separate the Grille from the Panel 3 Separate the Filter from the Panel 4 Separate 3 cover screws from it 5 Unscrew 6 fixed screws and separate them from the Indoor Unit Use Screw Driver 3 1 Indoor Unit Q Slim 1 way cassette type 9 6 B B a LQGG ...

Page 51: ...l from the Indoor Unit Panel Filter B type 1 Press Filter Reset Button on the wire less remote controller once Inlet Panel will descend as in the picture on the right 2 Rotate 2 levers that connect the both ends of the Inlet Panel and gear as in the picture on the right 3 Pull the Inlet Panel to the front to remove 9 6 B B a LQGG ...

Page 52: ...edure Remark 4 Remove the induction Filter 2EA 5 Remove the Filter Guide 2EA 6 Remove the 3 screws covers 7 Remove 4 Panel Connecting Wires and unscrew 7 Panel fixing Screws 8 After removing 2 Panel Fixing hooks separate the Panel and the Indoor unit 9 6 B B a LQGG ...

Page 53: ...ews from the Drain Pan Use Screw Driver 2 Pull the Drain Pan to separate them from the Indoor Unit When disassembling the Pan be careful not to touch the heat exchanger board with a bare hand 3 Control In 1 Undo 3 fixing screws in the Control In appliance part to separate the Cover Use Screw Driver 9 6 B B a LQGG ...

Page 54: ...y Samsung Electronics 3 6 No Parts Procedure Remark 2 Separate 8 connecters on the PCB of the Indoor Unit 3 Separate the Control In from the Indoor Unit 4 Drain Sub 1 Push the hook on the Drain Sub to separate it 9 6 B B a LQGG ...

Page 55: ...do fixing screw in the Heat Exchanger Use Screw Driver 2 Separate an Indoor Sensor from the Heat Exchanger 3 Separate the Heat Exchanger from the Indoor Unit 6 Cross Fan 1 Undo 3 fixing screws on the Cover Fan Motor Use Screw Driver 2 Separate the Cover Fan Motor from the Indoor Unit 9 6 B B a LQGG ...

Page 56: ... Parts Procedure Remark 3 Separate the Cross Fan from the Indoor Unit 7 Drain Pump 1 Separate fixing screw in the Cover Drain Pump Use Screw Driver 2 Separate the Drain Hose from the Drain Pump 3 Separate the Drain Pump from the Indoor Unit 9 6 B B a LQGG ...

Page 57: ...n the Grille and open it 2 Separate 1 clip from the Panel and tilt the grille to 90 and separate the grille from the panel 3 Separate the Filter from the Panel 4 Separate 4 cover screws 5 Unscrew 7 fixed screws and separate from the Indoor Unit Use Screw Driver Q Slim 1 way cassette type ND0561 0711HXE 9 6 B B a LQGG ...

Page 58: ...ixing screws from the Drain pan Use Screw Driver 2 Release the 2 hooks that holds the Drain Pan and remove the Drain Pan from the indoor unit When disassembling the Pan be careful not to touch the heat exchanger board with a bare hand 3 Electrical Part 1 Unscrew the 3 fixing screws in the Electrical part and separate the cover Use Screw Driver 9 6 B B a LQGG ...

Page 59: ...cedure Remark 2 Disconnect 8 connectors on the PCB of the Indoor Unit When there is chance of touching the indoor unit fan make sure the power is off you may get injured by the sharp edges of the fan 3 Separate the Electrical part from the Indoor Unit 9 6 B B a LQGG ...

Page 60: ...2 screws that fix the Cover Drain Pump Use Screw Driver 2 Release the Band Ring to separate the Drain Hose from the Drain Pump 3 Separate the Drain Pump from the Indoor Unit 5 Drain Sub 1 Unscrew the fixing screw for Drain Sub Use Screw Driver 2 Hold the hook on the Drain sub and separate it 9 6 B B a LQGG ...

Page 61: ...anger 1 Unscrew a fixing screw for Heat Exchanger Use Screw Driver 2 Separate the Indoor Sensor from the Heat Exchanger 3 Separate the EEV connector from the PCB 4 Separate the Heat Exchanger from the Indoor Unit 5 Separate the Expansion coil from the EEV Body For EEV service 9 6 B B a LQGG ...

Page 62: ...rocedure Remark 7 Cross Fan 1 Unscrew the 3 fixing screws on the Cover Fan Motor Use Screw Driver 2 Unscrew the fixing screw for Holder Fan Use Screw Driver When reassembling make sure that the end of the Holder Fan and Ass y cross Fan_L side aligns 9 6 B B a LQGG ...

Page 63: ... and Reassembly 3 15 Samsung Electronics No Parts Procedure Remark 1 Blower Motor 1 After disassembling 16 places indicating screws detach Ass y Cabi Bottom Blower Use Screw Driver Q SUPER Duct type 9 6 B B a LQGG ...

Page 64: ... from Assy control in the capacitor connection wire b w the motor fan housing connector 3 After disassembling 3 places indicating screws detach Fan Motor and Blower from the set 2 Control In 1 After disassembling 2 Indicating screw detach the Cover control Use Screw Driver 9 6 B B a LQGG ...

Page 65: ... fan sensor connector from the PCB 3 Disassemble 2 indicating screws and detach Control In from the set Use Screw Driver 3 Drain Pan Work is possible when Disassembling the Ass y Cabi Bottom Blower 1 Disassemble 7 indicating screws and detach Ass y Cabi Bottom Drain Use Screw Driver 9 6 B B a LQGG ...

Page 66: ...e Remark 2 Disassemble 4 indicating screws and detach the Drain Pan 2 screws each at left and right side Use Screw Driver 4 Evap Work is possible when Disassembling the Ass y Drain Pan 1 Disassemble 5 indicating screws to detach Cover Pipe Use Screw Driver 9 6 B B a LQGG ...

Page 67: ...amsung Electronics No Parts Procedure Remark 2 Disassemble Sensor on the Evap 3 Disassemble4indicatingscrewswhicharein thenearofHangerPlatetodetachtheEvap 2screwseachatleftandrightside Use ScrewDriver It needs 2 peoples 9 6 B B a LQGG ...

Page 68: ...OR BLOWER 1 Detach the motor connectors from the PCB 2 Unscew 16 screws and detach Cabinet Base Blower Use Screw Driver 3 Unscrew 8 screws and detach Case Blower Use Screw Driver 4 Unscrew 4 bolts and separate Motor blower from Bracket Motor Use Screw Driver Q BIG DUCT 9 6 B B a LQGG ...

Page 69: ...Separate Blower from the motor Use Screw Driver 2 EVAPORATOR DRAIN PAN 1 Detach EEV and Sensor connectors from the PCB Use Screw Driver 2 Unscrew 8 screws and Detach Cover Pipe Use Screw Driver 3 Unscrew 31 screws and detach Cabinet Base Blower andCabinet Base Drain Use Screw Driver 9 6 B B a LQGG ...

Page 70: ...embly and Reassembly Samsung Electronics 3 22 No Parts Procedure Remark 4 Unscrew 10 screws and detach Drain Pan from the indoor unit Use Screw Driver 5 Separate Evaporator from the indoor unit 9 6 B B a LQGG ...

Page 71: ...on in 1 Remove fixing screw from Cabinet and Separate the Cabinet from Outdoor unit Use Screw driver 2 Remove fixing screw from Cabinet and Separate the Cabinet from Outdoor unit Use Screw driver 3 Remove fixing screw separate the Control box cover and Separate the Power box cover Use Screw driver 9 6 B B a LQGG ...

Page 72: ...Disassembly and Reassembly Samsung Electronics 3 24 No Parts Procedure Remark 4 Remove fixing screw Separate the Electrical Component Box from the Outdoor unit Use Screw driver 9 6 B B a LQGG ...

Page 73: ...edure Remark 2 Motor Fan 1 Remove fixing screw from the Bell Mouth Use Screw Driver 2 Separate the Bell Mouth 3 Remove fixing bolt from the Fan 4 Separate the Fan from the Outdoor Unit 5 Remove fixing screw and after removing screws separate the Motor 9 6 B B a LQGG ...

Page 74: ... Vapor Injection 2 3 OIL SEPA OIL Return 1 4 Comp Oil Balance 2 4 OIL SEPA OIL SEPA Out 1 5 Comp PWM 1 5 OIL SEPA Discharge 1 6 Suction Oil Gas 1 6 SubCooler EVI BY Pass 1 7 Vapor Injection EVI BY Pass 1 7 SubCooler Expansion 1 8 4Way Oil SEPA Out 1 8 ACCUM Hot Gas 1 9 Cond In 4Way 1 9 Hot Gas 4Way 1 10 4Way ACCUM 1 10 Oil Gas Oil Return 1 11 Expansion Cond Out 1 11 Expansion Liquid BY Pass 1 12 O...

Page 75: ...re Sensor Hot gas valve 4 way valve Liquid ByassValve Temperature Sensor Suction BlackWire Temperature Sensor EVI Suction WihteWire Insulation No HP Insu Code BindingWire 8 10 12 DB62 04154B 1 2 4 5 9 10 12 DB62 03808G 8 10 DB62 03808B 8 10 12 DB62 03808C Valve Sensor No Valve Sensor MainEEV EVIEEV Temperature Sensor EVI In BlackWire Temperature Sensor Liuid Pipe WhiteWire Insulation No HP Insu Co...

Page 76: ...rature Sensor Sump 2 RedWire PowerWire CompWire Insulation No HP Insu Code BindingWire 8 10 12 DB62 03808C 8 10 12 DB62 03808C 5 8 9 8 10 12 DB62 03808C 1 2 5 6 10 11 Bending Holder Wire SensorWire COMP1 COMP2 t 5IF PVUTJEF UFNQFSBUVSF TFOTPS BOE UIF POE 0VU UFNQFSBUVSF TFOTPS BSF UP CF mYFE XJUI UIF DPOUSPM CPY BMPOH UIF JOUFSJPS TJEF PG UIF DBCJOFU BOE UIF interior of beam as shown in the image ...

Page 77: ...inside the box to fix and use the two holders so they can be tied together Use a holder assigned to BEAM to fix the MAIN POWER COMPWIRE and make sure they do not touch the relay or the fuse ASSY PBA CT LOW Only applied to 2 FAN and 3COMP model MAIN PBA o HUB BLDC COMM andWIRE must be fixed on the same path as the dotted lines MAIN PBA o HUB BLDC COMM andWIRE must be fixed on the same path as the d...

Page 78: ...rk 1 Common in 1 Remove fixing screw from Cabinet and Separate the Cabinet from Outdoor unit Use Screw driver 2 Remove fixing screw from Cabinet and Separate the Cabinet from Outdoor unit Use Screw driver 3 Remove fixing screw separate the Control box cover and Separate the Power box cover Use Screw driver 9 6 B B a LQGG ...

Page 79: ...Disassembly and Reassembly 3 31 Samsung Electronics No Parts Procedure Remark 4 Remove fixing screw Separate the Electrical Component Box from the Outdoor unit Use Screw driver 9 6 B B a LQGG ...

Page 80: ...edure Remark 2 Motor Fan 1 Remove fixing screw from the Bell Mouth Use Screw Driver 2 Separate the Bell Mouth 3 Remove fixing bolt from the Fan 4 Separate the Fan from the Outdoor Unit 5 Remove fixing screw and after removing screws separate the Motor 9 6 B B a LQGG ...

Page 81: ...or Injection 2 3 OIL SEPA OIL Return 1 4 Comp Oil Balance 2 4 OIL SEPA OIL SEPA Out 1 5 Comp PWM 1 5 OIL SEPA Discharge 1 6 Suction Oil Gas 1 6 SubCooler EVI BY Pass 1 7 Vapor Injection EVI BY Pass 1 7 SubCooler Expansion 1 8 4Way Oil SEPA Out 1 8 ACCUM Hot Gas 1 9 Cond In 4Way 1 9 Hot Gas 4Way 1 10 4Way ACCUM 1 10 Oil Gas Oil Return 1 11 Expansion Cond Out 1 11 Expansion Liquid BY Pass 1 12 Oil G...

Page 82: ... High Pressure Sensor Low Pressure Switch Hot gasValve 4wayValve Temperature Sensor Suction BlackWire Insulation No HP Insu Code BindingWire 16 18 20 22 DB62 03808A Valve Sensor No Valve Sensor Main EEV EVI EEV Temperature Sensor EVI In BlackWire Temperature SensorLiquid Pipe WhiteWire Temperature Sensor EVI Out WhiteWire Insulation No HP Insu Code BindingWire 14 DB62 03808E 14 DB62 03808C 14 DB62...

Page 83: ...Sensor Sump 1 RedWire Temperature Sensor Sump 2 RedWire Insulation No HP Insu Code BindingWire 16 18 20 22 DB62 03808C 16 18 20 22 DB62 03808C 1 2 3 4 5 6 7 8 9 t 5IF PVUTJEF UFNQFSBUVSF TFOTPS BOE UIF POE 0VU UFNQFSBUVSF TFOTPS BSF UP CF mYFE XJUI UIF DPOUSPM CPY BMPOH UIF JOUFSJPS TJEF PG UIF cabinet and the interior of beam as shown in the image t JY UIF NPUPS XJSF TP UIBU JU EPFT OPU UPVDI UIF...

Page 84: ...tied together Use a holder assigned to BEAM to fix the MAIN POWER COMPWIRE and make sure they do not touch the relay or the fuse ASSY PBA CT LOW Only applied to 2 FAN and 3COMP model MAIN PBA o HUB BLDC COMM andWIRE must be fixed on the same path as the dotted lines MAIN PBA o HUB BLDC COMM andWIRE must be fixed on the same path as the dotted lines Use a screw to fix the earth wire Pipe Welding Po...

Page 85: ... Vapor Injection 2 3 OIL SEPA OIL Return 1 4 Comp Oil Balance 2 4 OIL SEPA OIL SEPA Out 1 5 Comp PWM 1 5 OIL SEPA Discharge 1 6 Suction Oil Gas 1 6 SubCooler EVI BY Pass 1 7 Vapor Injection EVI BY Pass 1 7 SubCooler Expansion 1 8 4Way Oil SEPA Out 1 8 ACCUM Hot Gas 1 9 Cond In 4Way 1 9 Hot Gas 4Way 1 10 4Way ACCUM 1 10 Oil Gas Oil Return 1 11 Expansion Cond Out 1 11 Expansion Liquid BY Pass 1 12 O...

Page 86: ...witch High Pressure Sensor Low Pressure Switch Hot gasValve 4wayValve Temperature Sensor Suction BlackWire Insulation No HP Insu Code BindingWire 16 18 20 22 DB62 03808A Valve Sensor No Valve Sensor Main EEV EVI EEV Temperature Sensor EVI In BlackWire Temperature SensorLiquid Pipe WhiteWire Temperature Sensor EVI Out WhiteWire Insulation No HP Insu Code BindingWire 16 18 20 22 DB62 03808E 16 DB62 ...

Page 87: ...RedWire Temperature Sensor Sump 2 RedWire Temperature Sensor Sump 3 RedWire Insulation No HP Insu Code BindingWire 16 18 20 22 DB62 03808C C4 10 11 16 18 20 22 DB62 03808C 1 2 3 5 6 7 8 9 12 13 16 18 20 22 DB62 03808C 16 18 20 22 DB62 04154D 1 2 3 6 8 9 13 t 5IF PVUTJEF UFNQFSBUVSF TFOTPS BOE UIF POE 0VU UFNQFSBUVSF TFOTPS BSF UP CF mYFE XJUI UIF DPOUSPM CPY BMPOH UIF JOUFSJPS TJEF PG UIF cabinet ...

Page 88: ...ogether Use a holder assigned to BEAM to fix the MAIN POWER COMPWIRE and make sure they do not touch the relay or the fuse ASSY PBA CT LOW Only applied to 2 FAN and 3COMP model MAIN PBA o HUB BLDC COMM andWIRE must be fixed on the same path as the dotted lines MAIN PBA o HUB BLDC COMM andWIRE must be fixed on the same path as the dotted lines Use a screw to fix the earth wire Binding Wire Large Ch...

Page 89: ...cabinet from MCU 2 Cabinet front 1 Separate 4 fixing screws from the cabinet Use Serew Driver 2 Separate 4 fixing screws from the brackets Use Serew Driver 3 Cabinet front 1 Separate front cabinet from MCU 4 Control box cover 1 Separate 2 fixing screws from the control box cover Use Serew Driver 2 Separate control box cover from MCU 9 6 B B a LQGG ...

Page 90: ... Procedure Remark 1 Cabinet front 1 Separate 1 fixing screw from EEV kit Use Serew Driver 2 Separate cabinet from EEV kit 2 Control parts 1 Separate 2 fixing screws from EEV kit Use Serew Driver 2 Separate control part from EEV kit 9 6 B B a LQGG ...

Page 91: ...3 43 Samsung Electronics MEMO 9 6 B B a LQGG ...

Page 92: ...ing button 2 MAIN MICOM download AS PRO SMW200 07P white 6 Set up the number of connected outdoor units 3 Communications terminal for check up YW396 02V Brown 7 Outdoor unit Option Switch 4 ERROR DISPLAY 8 Condition Check SMW250 04 Red 5 2 1 7 3 8 4 6 4 Troubleshooting 4 1 Check up Window Description 9 6 B B a LQGG ...

Page 93: ...UIF PEF CVUUPO POF time to change it into 0 and then go to step 3 Step 3 Method Input the second digit of option code by pressing the temperature adjustment button up example 021E31142285 Result If 2 is displayed go to the step 4 whenever pressing the button 1 9 A B C D E F are lit in order 4 2 Troubleshooting 4 2 1 Setting Option Setup Method 4 2 1 1 PCB option code input method example 021E31142...

Page 94: ...button down example 021E31142285 Result If 1 is displayed go to the step 5 Step 5 Method Input the fourth digit of option code by pressing the fan speed adjustment button example 021E31142285 Result If E displays go to step 6 Step 6 Method Input the fifth digit of option code by pressing the On timer button example 021E31142285 Result If 3 displays go to step 7 SEG 5 9 6 B B a LQGG ...

Page 95: ...p 8 Step 8 Method After completion up to step 7 pressing mode button 1 7 steps are saved internally If the first number is 1 at the time it is correct So go to step 9 t G XBOUJOH UP TFF UIF TDSFFO of 2 7 steps press the mode button to make the first digit 0 Step 9 Method Input the eighth digit by pressing the temperature adjustment button up example 021E31142285 Result If 4 displays go to step 10 ...

Page 96: ...ure adjustment button down example 021E31142285 Result If 2 displays go to step 11 Step 11 Method Input the tenth digit by pressing fan speed adjustment button example 021E31142285 Result If 2 displays go to step 12 Step 12 Method Input the 11st digit by pressing the On timer button example 021E31142285 Result If 8 displays go to step 13 9 6 B B a LQGG ...

Page 97: ...e controller Operation mode SET TEMP fan speed displays Error If the On Off Timer and Fan indicator is flickering the wrong option code is input Put off the power of indoor unit and turn it on again and then input the option code again If the same error occurs it is the EEPROM is defective or not inserted Replace the PCB If all of On Off Timer Fan and Filter Sign indicator are flickering along wit...

Page 98: ...e which has a default Push the button to set the display panel to Every time you push the button the display panel reads repeatedly 3 Push the button to set the display panel to Every time you push the button the display panel reads repeatedly 4 5 6 Push the button to set the display panel to Every time you push the button the display panel reads repeatedly Push the button to set the display panel...

Page 99: ... set the display part to and check the display part The display part shows Press the Mode Selection key to set the display part to and check the display part The display part shows Step 4 Pressing the ON OFF button When pressing the operation ON OFF key with the direction of remote control for unit the sound Ding or Diriring is heard and the OPERATION ICON lamp of the display is flickering at the ...

Page 100: ...p 1 Entering mode to set option 1 Remove batteries from the remote controller 2 Insert batteries and enter the option setting mode while pressing High Temp button and Low Temp button 3 Check if you have entered the option setting status Step 2 The procedure of option setting After entering the option setting status select the option as listed below Option setting is available from SEG1 to SEG 24 t...

Page 101: ...SEG8 option Press Low Fan button to enter SEG6 value Press High Fan button to enter SEG8 value Each time you press the button will be selected in rotation 6 Setting Fan mode Press Mode button to be changed to FAN mode in the ON status 7 Setting SEG9 SEG10 option Press Low Fan button to enter SEG9 value Press High Fan button to enter SEG10 value Each time you press the button will be selected in ro...

Page 102: ...ge to Dry mode in the OFF status 15 Setting SEG18 SEG20 option Press Low Fan button to enter SEG18 value Press High Fan button to enter SEG20 value Each time you press the button will be selected in rotation 16 Setting Fan mode Press Mode button to be change to Fan mode in the OFF status 17 Setting SEG21 SEG22 option Press Low Fan button to enter SEG21 value Press High Fan button to enter SEG22 va...

Page 103: ...p 4 Input option Press operation button with the direction of remote control for set For the correct option setting you must input the option twice Step 5 Check operation 1 Reset the indoor unit by pressing the RESET button of indoor unit or outdoor unit 2 Take the batteries out of the remote controller and insert them again and then press the operation button 9 6 B B a LQGG ...

Page 104: ...10 SEG11 SEG12 1 Drain pump Hot water heater Electronic heater Opening the electronic expansion valve Master Slave SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 2 External control External control output S Plasma ion Buzzer Number of hours VTJOH mMUFS SEG19 SEG20 SEG21 SEG22 SEG23 SEG24 3 Individual control of a remote controller Heating setting compensation EEV opening of an indoor unit stopped during oil ...

Page 105: ...SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 Explanation PAGE Use of external control Setting the output of external control S Plasma ion Buzzer control Number of hours VTJOH mMUFS Remote Controller Display Indication and Details Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details 2 0 Disuse 0 Thermo on 0 Disuse 0 Mixedoperation control1 Use buz...

Page 106: ...4 0 2 2 C 2 0 0 0 0 0 3 0 0 0 0 0 AVXDSH036E ND036LHXE 0 1 5 2 0 1 1 6 0 3 A 0 2 0 0 0 0 0 3 0 0 0 0 0 Slim Duct 2 AVXDSH045E ND045LHXE 0 1 5 2 2 3 1 7 0 1 3 5 2 0 0 0 0 0 3 0 0 0 0 0 AVXDSH056E ND056LHXE 0 1 5 2 2 3 1 9 0 1 B A 2 0 0 0 0 0 3 0 0 0 0 0 AVXDSH071E ND071LHXE 0 1 5 2 2 3 1 C 0 3 9 E 2 0 0 0 0 0 3 0 0 0 0 0 Slim Duct 3 BLDC AVXDSH090E ND090LHXE 0 1 5 2 1 4 1 E 0 0 d 4 2 0 0 0 0 0 3 0 ...

Page 107: ...mmAq 0 1 5 A 2 4 1 2 0 2 A 6 2 0 0 0 0 0 3 0 0 0 0 0 20mmAq ND140HHXEB 0 1 5 A 2 3 1 3 0 1 9 D 2 0 0 0 0 0 3 0 0 0 0 0 5mmAq 0 1 5 A 2 3 1 3 0 1 C F 2 0 0 0 0 0 3 0 0 0 0 0 10mmAq 0 1 5 A 2 4 1 3 0 2 2 3 2 0 0 0 0 0 3 0 0 0 0 0 15mmAq 0 1 5 A 2 4 1 3 0 2 F F 2 0 0 0 0 0 3 0 0 0 0 0 20mmAq SUPER Duct AVXDUH210E 0 1 5 A 0 0 1 6 0 0 0 0 2 0 0 0 0 0 3 0 0 0 0 0 AVXDUH280E 0 1 5 A 0 0 1 7 0 0 0 0 2 0 0...

Page 108: ...0 0 0 3 0 0 0 0 0 AVXWVH036E ND036VH 0 0 7 6 0 2 1 5 2 2 1 A 2 0 0 0 0 0 3 0 0 0 0 0 AVXWVH056E ND056VH 0 0 5 6 0 6 1 A 2 2 5 E 2 0 0 0 0 0 3 0 0 0 0 0 AVXWVH071E ND071VH 0 0 5 6 0 6 1 C 2 3 7 1 2 0 0 0 0 0 3 0 0 0 0 0 Neo Forte without EEV AVXWNH022E ND022NH 0 2 7 6 0 2 1 1 2 0 F A 2 0 0 0 0 0 3 0 0 0 0 0 AVXWNH028E ND028NH 0 2 7 6 0 2 1 3 2 0 F A 2 0 0 0 0 0 3 0 0 0 0 0 AVXWNH036E ND036NH 0 2 7 ...

Page 109: ...nication between the indoor unit and outdoor unit for 2 minutes When communication error is for over 2 minutes 2 The indoor unit receives the communication error signal from the outdoor unit 3 The outdoor unit tracking 3 minutes error 4 When the outdoor unit transmits a communication error which is caused by difference between the number of the installation unit and the number of communication uni...

Page 110: ... switch 2nd detection COMP DOWN 10 Reverse phase detection error 11 Freezing 6th detection compressor stop 12 Compression sensor self diagnosis G8 G9 13 Compressor down error by compression ratio control Flot switch detection Peripheral control device option setting error EEPROM error EEPROM option error SPI error t 0VUEPPS 6OJU PS TFMG EJBH nosis error Outdoor unit operation error Overflow of con...

Page 111: ...r unit for 2 minutes When communication error is for over 2 minutes 2 The indoor unit receives the communication error signal from the outdoor unit 3 The outdoor unit tracking 3 minutes error 4 When the outdoor unit transmits a communication error which is caused by difference between the number of the installation unit and the number of communication unit after completion of tracking When communi...

Page 112: ...on 18 DISCHARGE high temperature 2nd detection 19 Low pressure switch 2nd detection COMP DOWN 10 Reverse phase detection error 11 Freezing 6th detection compressor stop 12 Compression sensor self diagnosis G8 G9 13 Compressor down error by compression ratio control Flot switch detection Peripheral control device option setting error EEPROM error EEPROM option error SPI error Outdoor Unit Operation...

Page 113: ...unit for 2 minutes When communication error is for over 2 minutes 2 The indoor unit receives the communication error signal from the outdoor unit 3 The outdoor unit tracking 3 minutes error 4 When the outdoor unit transmits a communication error which is caused by difference between the number of the installation unit and the number of communication unit after completion of tracking When communica...

Page 114: ...tection 17 COND high temperature 2nd detection 18 DISCHARGE high temperature 2nd detection 19 Low pressure switch 2nd detection COMP DOWN 10 Reverse phase detection error 11 Freezing 6th detection compressor stop 12 Compression sensor self diagnosis G8 G9 13 Compressor down error by compression ratio control Flot switch detection Peripheral control device option setting error EEPROM error EEPROM o...

Page 115: ...tion error is for over 2 minutes 2 The indoor unit receives the communication error signal from the outdoor unit 3 The outdoor unit tracking 3 minutes error 4 When the outdoor unit transmits a communication error which is caused by difference between the number of the installation unit and the number of communication unit after completion of tracking When communication error is for over 2 minutes ...

Page 116: ...rature 2nd detection 18 DISCHARGE high temperature 2nd detection 19 Low pressure switch 2nd detection COMP DOWN 10 Reverse phase detection error 11 Freezing 6th detection compressor stop 12 Compression sensor self diagnosis G8 G9 13 Compressor down error by compression ratio control Plot switch detection Peripheral control device option setting error EEPROM error EEPROM option error Outdoor Unit O...

Page 117: ...on error for more than 2 minutes 2 Indoor unit receiving the communication error from outdoor unit 3 Outdoor unit tracking 3 minute error 4 When sending the communication error from outdoor unit due to the mismatching of the communication numbers and installed numbers after completion of tracking communication error for more than 2 minutes Self diagnostic error including the indoor unit not detect...

Page 118: ...e phase 11 Compressor down due to 6th detection of freezing 12 Self diagnosis of condensation sensor G8 G9 13 Compressor down due to condensation ratio control Error of float switch Error of setting option switches for optional accessories EEPROM error EEPROM option error Displayed on appropriate indoor unit which is operating Displayed on outdoor unit On Flickering Off If you turn off the air con...

Page 119: ...e outdoor temperature sensor Error of the condensor temperature sensor Error of the discharge temperature sensor Indoor Fan Motor is non operative Indoor Fan Motor is operating slowly Indoor Fan Motor operates at an excessive speed Indoor Fan Motor Error 1 Indoor and outdoor unit time out 2 Abnormal data reception more than 60 packet 3 Indoor unit is not connected 4 Communication error between the...

Page 120: ...rror Inverter Inverter compressor operation failure Inverter DC peak error Inverter DC Link voltage 150V or less 410V or more Inverter Compressor rotation error Inverter Electric current error Inverter DC Link sensor error Inverter EEPROM READ WRITE error Inverter Inverter zerocrossing error Setting the outdoor unit capacity option error Error of setting option switches for optional accessories EE...

Page 121: ... LED lamp display at error detecting Wall mounted type Neo Forte without EEV with EEV Abnormal conditions LED lamp display Remark OPERATION TIMER TURBO Indoor unit room temperature sensor error open or short Indoor unit heat exchanger temperature sensor error open or short Indoor fan motor malfunction EEPROM error Option Setting Option error option wasn t set up or option data error Option Setting...

Page 122: ...ndoor unit heat exchanger in temperature sensor detached Heat exchanger in sensor Indoor unit heat exchanger out temperature sensor detached Heat exchanger out sensor Indoor unit heat exchanger in out temperature sensor detached Heat exchanger in out sensor Indoor unit fan motor malfunction Fan motor and cable More than 2 indoor units cool and heat simultaneously Another indoor unit operation mode...

Page 123: ...U Cable remote control wall mount etc Q Outdoor Unit Meanings of First Alphabetical Character Number of Error Code Classification Error display method Display Example Display method for error that occurred in indoor unit Error Number o Indoor unit address o Error Number repeat display E471 o A002 o E471 o A002 Display method for error that occurred in outdoor unit and other methods of error display...

Page 124: ...e outdoor unit is installed t 0VUEPPS VOJU 8BZ WBMWF t 0VUEPPS VOJU JRVJE WBMWF t 0VUEPPS VOJU 7 7 t 0VUEPPS VOJU BJO 7 will only be identified when running auto inspect on heating mode Auto inspect mode may be terminated in the event of an error in the operation evaluation state If auto inspect mode needs to be terminated please press the reset button K3 on the outdoor unit If outdoor units that ...

Page 125: ... TZTUFN QSPUFDUJPO DPOUSPM NBZ UVSO PO JG PQFSBUJOH CFUXFFO UIF DVTQ PG UIF DPPMJOH IFBUJOH SFHJPOT Normal auto inspection may be difficult if protection control is turned on t O B DPNCJOFE NPEVMF TUBUF JG UIF TVC PVUEPPS VOJU TUPQT JO UIF NJEEMF PG PQFSBUJPO EVF UP MPBEJOH DPOEJUJPOT TVCTFRVFOU evaluations will not be identified Treated as Unconfirmed t 1MFBTF VTF UIF BVUP JOTQFDU NPEF XIFO UIF J...

Page 126: ...or outdoor units t BJO BO CMBEFT t 4FOTPS 0QFO 4IPSU t 4BWF 4 BOE 0QUJPO WBMVFT Operation evaluation t FUFSNJOF DPPMJOH IFBUJOH auto inspect mode t OEPPS VOJU WB JO PVU TFOTPS evaluation t PNQ PQFSBUJPO FWBMVBUJPO t 4FSWJDF WBMWF MPDL FWBMVBUJPO t 0UIFS QSPUFDUJPO TQFDJBM operation general control Safety evaluation t 1SFTTVSF TFOTPS FWBMVBUJPO t PNQSFTTPS PQFSBUJPO DVSSFOU evaluation t 0JM CBMBODF...

Page 127: ...check card and preliminary inspection sheet t 1MFBTF GJMM PVU UIF JOTUBMMBUJPO DIFDL DBSE BUUBDIFE UP UIF DPOUSPM CPY PG UIF PVUEPPS VOJU t 5IFSF JT B QSFMJNJOBSZ JOTQFDUJPO TIFFU QSJOUFE PO UIF CBDL PG UIF DBSE 1MFBTF GJMM UIJT PVU BOE TUPSF JU JO UIF TUPSBHF BSFB JOTJEF UIF control box Preliminary Inspection t OTQFDU JOTUBMMBUJPO PG JOEPPS BOE PVUEPPS units t JMM PVU DIFDL DBSE BOE QSFMJNJOBSZ i...

Page 128: ...re range Errors and inspection requirements may occur even if the installation location and conditions of the system are met Therefore if errors or inspection requirements occur please determine if there are any faults after running cycle operation data analyses and various sensor inspections Yes Yes Yes No No No Start auto inspect mode Is there an error inspected item Re run auto inspect mode Sys...

Page 129: ... please run the auto inspect mode after running air modes for all installed indoor units for at least 10 minutes Air intake indoor units are exempted from auto inspections of the indoor temperature and Eva In Out temperature sensor Yes Do the indoor and Eva in out temperatures deviate by more than 10 C Run air operation for more than 10 minutes Yes Yes Yes No No No No Is the temp sensor connector ...

Page 130: ...tire outdoor unit vacuum mode End Open outdoor unit service valve Reset outdoor unit Perform test run Analyze cycle data check replace faulty pressure sensor Does the pressure sensor value of the installed outdoor unit satisfy Maximum minimum range of high pressure Maximum minimum range of low pressure under 2 No No Pressure sensor auto inspect will not run if outdoor unit is installed by itself W...

Page 131: ...ease run heating operation or test run for at least 1 hour Errors may occur even in normal conditions if outside of the guaranteed range Yes Yes Yes Is the service valve of the installed outdoor unit open Open service valve Inspect 4 way valve Main EEV Inspect system for leaks Insert vacuum refrigerant Did the 4 way valve Main EEV run normally Is there a suitable amount of refrigerant in the syste...

Page 132: ...g properly Is the CT sensor Connector connected properly Is the Comp CT value at 0 when the outdoor unit is in a Stop state Test run mode End Is the compressor operating Is the current reading result and CT sensor value the same for the relevant compressor Is the PWM valve working normally Does the relevant compressor current value satisfy 4 compressor CT 20 Correct power cable connection Replace ...

Page 133: ...spection required is determined for compressor operation an error will be displayed on the relevant outdoor unit When Inspection required is determined for compressor operation auto inspect will end Problematic compressors can be checked using the result report of S net pro 9 6 B B a LQGG ...

Page 134: ... the auto inspect guaranteed range b IfThermo On Off occurs in the indoor unit during inspection c If outdoor unit is implanted or if cold air is prevented from running in the indoor unit during inspection Yes Does the function evaluation result show all valve types as normal 1 Run test run mode for at least 60 minutes 2 Run air operation for at least 10 minutes 3 Re start auto inspect mode Yes Yes...

Page 135: ...run mode for at least 60 minutes 2 Run air operation for at least 10 minutes 3 Re start auto inspect mode Is the current reading esult and CT sensor value the same for the relevant compressor Is the compressor operation current normal Is the interphase resistance of the compressor normal End Replace CT sensor Yes Yes Yes No No No No No No Check correct supplied power specifications and loose Re co...

Page 136: ...E QMFBTF QFSGPSN UIF JOTQFDUJPO JO UIF GPMMPXJOH PSEFS Error code None Print the S net pro result report Inspection required Yes Is the Connector of the PWM valve connected properly Replace Body Yes Yes No No No Is the Coil of the PWM valve disconnected Is the PBA output signal normal End Replace Coil Re connect Connector Replace PBA PWM valve coil operation voltage AC220 240V 50 60Hz 9 6 B B a LQ...

Page 137: ...nutes 2 Run air operation for at least 10 minutes 3 Re start auto inspect mode Is the valve normal Is there a change in pipe temperature following the valve s actions End Yes Yes No No No No No No Inspect relevant valve Re connect Connector Replace Coil Replace PBA Replace Body Yes Yes An Inspection required may occur even in normal conditions depending on the installation location and temperature...

Page 138: ...nt the S net pro result report inspection required Yes Does the function evaluation result show other valve as normal Is the 4 way valve s Connector connected properly Is the Coil of the 4 way valve disconnected Is the PBA output signal normal Replace 4 way valve body perform auto inspect again End Yes Yes Yes No No No No Inspect relevant valve Re connect Connector Replace Coil Replace PBA 4 way v...

Page 139: ...alve Re connect Connector Put Body Coil in normal position Replace Coil Inspect EVI IN sensor Connect Inspect for loose EVI IN sensor An Inspection required may occur even in normal conditions depending on the installation location and temperature conditions Before running an inspection please determine after running a Data analysis of S net pro Examples of when Inspection required can occur even ...

Page 140: ...quired can occur even in normal conditions a If outside the auto inspect guaranteed range b IfThermo On Off occurs in the indoor unit during inspection c If outdoor unit is implanted or if cold air is prevented from running in the indoor unit during inspection Yes Does the function evaluation result show other valve as normal 1 Reset outdoor unit 2 3 times initialize EEV 2 Run air operation for at ...

Page 141: ...ode or cooling mode 20 E 162 EEPROM error of MICOM Physical damage 21 E 163 Option code error of indoor unit s EEPROM 22 E 137 Option setting error of indoor unit s dip switch 23 E 170 Temperature display setting error for USA market product Mixed setting with Celsius and Fahrenheit temperature 24 E 180 Opening error of cooling and heating solenoid valve simultaneously in MCU 1st detection 25 E 18...

Page 142: ...n or Short 56 E 258 Discharge temperature sensor of compressor 3 Open or Short 57 E 261 Discharge temperature sensor of compressor 1 is detached from the sensor hold of the pipe 58 E 262 Discharge temperature sensor of compressor 1 is detached from the sensor hold of the pipe 59 E 263 Discharge temperature sensor of compressor 2 is detached from the sensor hold of the pipe 60 E 264 Discharge tempe...

Page 143: ...cklash error of outdoor unit s fan motor 97 E 458 Over current of CT sensor 98 E 461 Low current of CT sensor 99 E 477 Stop compressor because liquid refrigerant get into the compressor 100 E 559 Indoor unit stop by unidentified error from outdoor units 101 E 560 Option switch setting error of outdoor unit Inapplicable option switch turns on 102 E 561 Fan RPM error of ERV SA Supply air 103 E 562 F...

Page 144: ...1 Option switch setting error of wired remote controller Master Slave 124 E 652 Two wired remote controllers were set to the master mode COM 1 wiring 125 E 653 Room temperature sensor in the wired remote controller Open or Short 126 E 654 Memory data error in the wired remote controller MWR WS00 127 E 701 Floating switch error of indoor unit 1st detection 128 E 702 EEV closing error of indoor unit...

Page 145: ...ration 135 Indoor clean fan rotational frequency feedback error t IFDL UIF GFFECBDL DPOOFDUJPO MJOF t IFDL UIF SPUBUJPOBM PVUQVU PG UIF DMFBO GBO NPUPS t IFDL JG UIF NPUPS PQFSBUFT XFMM 1 Normal operation Normal in other Functions Normal operation page 4 67 151 The 2nd opening error of indoor electrically operated valve t IFDL UIF 1 DPOOFDUJPO PG FMFDUSJDBMMZ PQFSBUFE WBMWF XJSF t IFDL UIF TFBMJOH...

Page 146: ...emperature changes in incorrect indoor unit EVA_IN t IFDL JG UIF JOEPPS VOJU 3 44 JT TBNF BT UIF TFU 3 44 PO 6 t IFDL UIF 6 JOEPPS VOJU TFUUJOH TXJUDI 1 Normal operation Operation off Normal operation page 4 78 191 While pipe testing there are no temperature difference in EVA_OUT or temperature changes in incorrect indoor unit EVA_OUT t IFDL JG UIF JOEPPS VOJU 3 44 JT TBNF BT UIF TFU 3 44 PO 6 t I...

Page 147: ...f page 4 91 217 While MCU pipe use setup switch turned off IU is registered t IFDL UIF DPOOFDUJPO QJQJOH CFU 6 6 t IFDL UIF 6 CSBODI QBSU TFUVQ TXJUDI OEPPS 6OJU BEESFTT TXJUDI TFUVQ 1 Operation off Operation off Operation off page 4 92 218 When the no of registered IUS in MUC is at least one unit more than the no installed t IFDL UIF DPOOFDUJPO QJQJOH CFU 6 6 t IFDL UIF 6 CSBODI QBSU TFUVQ TXJUDI...

Page 148: ... Yes Normal operation Tracking completion E201 error Tracking error ch display E425 error reversed phase no phase error 3 phase power check Is it normal Crank case heater Is preheating completed 4 5 Responses According to Condition 4 5 1 Outdoor Unit Operation Flow 9 6 B B a LQGG ...

Page 149: ... take the appropriate measures 3 If the 3 phase voltage is normal then use the 3 phase tester to display the phase of the power cable Change the power cable connection if reversed phase is displayed 4 Take the above measures press the reset key K3 and then check the power once more 5 If the same problem occurs after another check check the 3 phase power check cable for its color If there is no pro...

Page 150: ...laying parts will display 2 Sub Slave Unit Displays the Micom address of the main PBA inside the sub unit connected to the master unit in order Example C9 CA CB CC CD CE DF g SEG1 a f G1 G2 b c e d SEG2 g SEG3 a f G1 G2 b c e d SEG4 Outdoor Unit Display Parts 3 If the quantity of the indoor units configured with the indoor unit installation quantity setup switch does not match the quantity of the ...

Page 151: ...ll continue to blink on the display module and CCH crank case heater will heat the compressor for 2 and a half hours The compressor cannot be operated during this time and it will be ready for operation once the compressor is sufficiently preheated for 2 and a half hours and the Ch stops flashing 4 The judgment of whether it is possible to operate according to the temperature of the compressor is ...

Page 152: ...blem Yes Yes Is indoor room temperature sensor connector dislocated At that time is the resistance value significantly deviated from the temp table After separating indoor room temperature sensor connector from PCB measure the resistance values between both terminals Re start after replacing PCB Re start after connecting the connector to the PCB As it is due to an indoor oom temperature sensor def...

Page 153: ... check Is indoor EVAP IN sensor connector separated from the PCB At that time is the resistance value significantly deviated from the temp table After separating indoor EVAP IN sensor connector from the PCB measure the resistance values between both terminals Re start after connecting the connector to the PCB As it is due to an indoor EVAP IN sensor defect replace it Yes No No Ex Room temp 26 C Re...

Page 154: ...check Is indoor EVAP OUT sensor connector separated from the PCB At that time is the resistance value significantly deviated from the temp table After separating indoor EVAP OUT sensor connector from the PCB measure the resistance values between both terminals Re start after replacing PCB Re start after connecting the connector to the PCB As it is due to an indoor EVAP OUT sensor defect replace it...

Page 155: ... Tair out 3 C OK Tair in Teva out 4 C NO Tair in Teva out 4 C OK Compressor in operation Indoor unit operation Thermo On OK Error details Indoor heat exchanger s EVAP IN sensor dislocation error 2 During heating operation Average high pressure 25kg OK Average low pressure 8 5kg OK Tcond out Tair out 3 C OK Tair in Teva out 2 C NO Tcond out Tair out 2 C OK Compressor in operation Indoor unit operat...

Page 156: ...nd out Tair out 3 C OK Tair in Teva out 4 C NO Tair in Teva out 4 C OK Compressor in operation Indoor unit operation Thermo On OK Error details Indoor heat exchanger s EVA IN sensor dislocation error 2 During Heating operation Average high pressure 25kg OK Average low pressure 8 2kg OK Tcond out Tair out 3 C NO Tair in Teva out 2 C NO Tcond out Tair out 2 C OK Compressor in operation Indoor unit o...

Page 157: ...ils Simultaneous indoor heat exchanger s EVA IN OUT sensor dislocation error 2 During Heating operation Average high pressure 25kg OK Average low pressure 8 2kg OK Teva out Tair out 3 C NO Tair in Teva out 2 C NO Tcond out Tair out 2 C OK Compressor in operation Indoor unit operation Thermo On OK Error details Simultaneous Indoor heat exchanger s EVA IN OUT sensor dislocation error 2 How to check ...

Page 158: ... Outdoor unit display 1 How to diagnose Occurs when RPM values are not sent as feedback to MICOM at a PID control type fan motor 2 How to check 1 Check the HALL IC connector that carries out RPM value feedback 2 If the operational capacitor is a PCB separation type check the connection terminal 3 Check the operation status of fan motor 4 If there is no problem with the above checkup items replace ...

Page 159: ... is any rust on the surface of the electronic expansion valve with naked eyes then check the resistance between each terminal to find any wire breaking or short circuit 4 Press the RESET KEY K3 of the outdoor unit then see if the same error occurs 4 In case of closure problem operate the indoor unit in which the error has occurred 4 In case of opening problem please do not operate the indoor unit ...

Page 160: ... any rust on the surface of the electronic expansion valve with naked eye then check the resistance between each terminal to find any wire breaking or short circuit 4 Press the RESET KEY K3 of the outdoor unit then see if the same error occurs 4 In case of closure problem operate the indoor unit in which the error has occurred 4 In case of opening problem please do not operate the indoor unit in w...

Page 161: ...check if drain pump operates vibrates during operation Normal operation Indoor unit s power reset after replacement Reassembly Floating Sensor Connector and reset Outdoor Unit power Indoor unit power reset required Normal operation Diagnosed as a defective Floating sensor Indoor unit s power reset after replacement Replace Drain pump Replace Drain pump Replace Indoor Unit PCB Error occurs Operatio...

Page 162: ...e below Indoor unit display Criteria Cause of problem Outdoor unit display 1 How to diagnose 1 Occurs when RPM valve fails to feedback to MICOM at a PID control type fan motor 2 How to check 1 Check HALL IC connector that carries out feedback of RPM value 2 If a fan motor operation capacitor is a PCB separating type check the connection terminal 3 Check the operational status of the fan motor 4 If...

Page 163: ... problem but is displayed when the operational mode input in an indoor unit is different from current operational status other indoor unit s operational mode Check the operational mode of outdoor unit or other indoor unit then re enter or stop the operational mode of the relevant unit If it is necessary to apply a different operational mode to an indoor unit from others please stop other indoor un...

Page 164: ... t Communication failure between EEPROM and MICOM Outdoor unit display Yes Are there any problems such as short or dewetting between EEPROM PIN If you restart after reentering model options and power reset does the error occur again Replace PCB Yes No Normal operation No 1 How to check Check the location of EEPORM by referring to the schematic diagram Replace PCB 9 6 B B a LQGG ...

Page 165: ... then enter correct options 4 5 16 Error due to confused use of Fahrenheit and Celsius Indoor unit display Operation Timer Fan Filter Defrost t JTTFE JOQVU PG SFNPUF DPOUSPMMFS PQUJPOT Criteria Cause of problem t JTQMBZ OVNCFS UZQF PG JOEPPS VOJU o PDDVST BNQ UZQF o BMM MBNQT GMBTI t 0DDVST JO BO JOEPPS VOJU XJUI FMTJVT TFUUJOH Outdoor unit display Check relevant remote controller options for each...

Page 166: ...p methods 1 How to check Yes Are an indoor unit address cooling heating position of the MCU SOL VALVE connector correctly connected Check the indoor unit address cooling heating position and make the correct connection Yes No Yes Replace MCU SOL VALVE BODY Is a coil of MCU SOL VALVE Correctly connected Check the coil connection and fasten it again No When you restart it after replacing MCU SOL VAL...

Page 167: ...e Connection Indoor unit display t Apply power 220V to the terminal of the indoor unit communication block F1 F2 Criteria Cause of problem t Check for Power input 220V for the Terminal block F1 F2 Outdoor unit display Check for disconnected line after turning off the Main power wall mount type 9 6 B B a LQGG ...

Page 168: ...iteria Cause of problem t Check if the output of SPI Feedback is 12V Outdoor unit display 1 How to check 예 Is the SPI connector of an indoor unit separated from PCB Connect the connector to PCB and reoperate Yes No Replace Main PCB Can you measure 12V from 1 4 power with SPI connector being connected Replace SPI No Yes 1 4 9 6 B B a LQGG ...

Page 169: ...vant MCU ports Check if the indoor unit usage setup switch is turned on for the MCU port connected to the indoor unit Outdoor Unit Display No change of EVA IN or wrong EVAN IN change during pipe inspection No change of EVA OUT or wrong EVA OUT change during pipe inspection Indoor Unit Display Judgment Method t 3FGFS UP UIF KVEHNFOU NFUIPE CFMPX Special Cause t 5IF MJRVJE QJQF HBT QJQF PG UIF JOEPP...

Page 170: ...unit If there is no peculiarity then connect the indoor units one by one to find the indoor unit that is interfering with the communication for inspection and change the indoor unit PCB Is the voltage between the 2 cables a square wave with DC 0 7V or more Are the number of actual installed indoor units and the set value for the installation quantity setup switch the same Correctly set the indoor ...

Page 171: ...I Above Yellow Connector of Each Unit Communication IC between outdoor units Other Outdoor Unit Above Communication Connector Communication IC between indoor and outdoor units 2 Measure the resistance of the communication IC Measurement Method Measure the No 5 No 6 Pin resistance Measure the No 5 No 7 Pin resistance 3 Both lights are tested for communication IC by using measured resistance Judging...

Page 172: ...e outdoor unit to the indoor nit and measure the 2 outdoor unit cables with a scope Connect the communication cable again to connect the outdoor unit to the indoor unit Remove all the communication connectors on the PCB of the indoor unit and connect them one by one to find the indoor unit which interferes with the communication to check and change the indoor unit PCB After two minutes find the in...

Page 173: ...Judgment Method Special Cause Outdoor Unit Display 1 Faulty communication between outdoor units Reset error Key 3 Check the outdoor unit with error U200 U201 U202 U203 Is the power supply normal 15V 5V Check wiring of outdoor unit communication cable Check K13 and K14 setup options for outdoor unit Change PCB Check power Change wiring or connect Change settings Yes Yes Yes No No No Essential Requi...

Page 174: ...one by one to find the MCU which interferes with the communication to check and change the MCU PCB Is the voltage between the 2 cables a square wave with DC 0 7V or more Are the quantity of the actually installed MCUs and the set value of the installation quantity setup switch the same Correctly set the installation quantity setup switch of the outdoor unit MCU and press the reset key K3 of the ou...

Page 175: ... DPOOFDUJPO GPS DPOOFDUJPO DBCMF CFUXFFO 1 l HUB PAB t GUFS DIBOHJOH 1 DIFDL GPS SFPDDVSSFODF PG UIF DPNNVOJDBUJPO FSSPS Judgment Method Special Cause t PNNVOJDBUJPO FSSPS CFUXFFO PVUEPPS 1 BOE 6 1 Outdoor Unit Display Indoor Unit Display Operation Reservation Blast Filter Defrost 9 6 B B a LQGG ...

Page 176: ...the MCU and measure the 2 cables of the outdoor unit with a scope Connect the communication cable which connects the outdoor unit to the MCU again remove all communication connectors from the MCU PCB Connect each unit one by one and find the MCU which interferes with communication to check and change the MCU PCB After two minutes find the MCU which displays the communication error and check if the...

Page 177: ...onsecutively Outdoor unit display 1 How to check Find an MCU that is composed as the following picture to carry out assembly of branch part again After completing the re setting press K3 button on the button to reset or turn it off to restart Indoor unit display MCU BOX 0 MCU PCB OFF MCU address setup ON Setting error Indoor unit Indoor unit address Branch part use setup 4 2 1 2 5 6 0 Branch A 4 B...

Page 178: ...MCU Outdoor unit display 1 How to check Find an MCU that is composed as the following picture to carry out assembly of branch part again After completing the re setting press K3 button on the button to reset or turn it off to restart Indoor unit display MCU BOX 0 MCU PCB OFF MCU address setup ON Setting error Indoor unit Indoor unit address Branch part use setup 4 2 2 2 5 6 0 Branch A 4 B 2 C D E ...

Page 179: ...TUFSFE JOEPPS VOJUT Outdoor unit display 1 How to check Find an MCU that is composed as the following picture to carry out assembly of branch part again After completing the re setting press K3 button on the button to reset or turn it off to restart Indoor unit display MCU BOX 0 MCU PCB OFF MCU address setup ON Indoor unit Indoor unit address Branch part use setup 4 4 2 1 5 6 0 Branch A 4 B C D E ...

Page 180: ... it on again Indoor Unit Display MCU BOX 0 Outdoor Unit PCB MCU PCB OFF MCU Address Setup MCU Address Setup Setup for Indoor Quantity Used MCU Address Setup Setup for Indoor Quantity Used ON Indoor Unit Indoor Unit Indoor Unit Address Setup for Using Branch Sphere 4 4 2 1 5 5 1 6 0 Branch Sphere A 4 B C D E 5 F 6 MCU BOX 1 MCU PCB OFF ON 1 3 7 9 0 0 1 Branch Sphere A B D E 0 7 F 1 MCU BOX 0 Outdoo...

Page 181: ...ff to restart MCU BOX 0 MCU PCB OFF MCU address setup ON Indoor unit address Branch part use setup 4 2 2 0 5 6 0 Branch A B C D E F MCU BOX 1 MCU PCB OFF MCU address setup ON Indoor unit address Branch part use setup 4 0 1 2 5 7 1 Branch A B C D E F t 3FQFBUFE JOEPPS VOJU address Criteria Cause of problem t 0DDVST XIFO BO JOEPPS VOJU BEESFTT TFUVQ TXJUDI JO 6 IBT CFFO PWFSMBQQFE Outdoor unit displ...

Page 182: ... After completing resetting press the outdoor unit s K3 button to reset or turn off to restart t 1JQF JT OPU JOTUBMMFE UP UIF JOEPPS VOJU XJUI BTTJHOFE address on MCU Criteria Cause of problem t 0DDVST XIFO 6 1 1 JT TFU BT CFJOH VTFE ZFU OPU DPOOFDUFE UP BO JOEPPS VOJU Outdoor unit display Indoor unit display MCU BOX 1 MCU PCB OFF ON 1 3 7 9 0 0 1 Branch A B C D E 0 F Operation Timer Fan Filter De...

Page 183: ... VOJU JT SFHJTUFSFE Outdoor unit display 1 How to check Check the actual use of the branch part If it is used turn on the Dip switch for branch part setup After completing resetting press the outdoor unit s K3 button to reset or turn off to restart Indoor unit display MCU BOX 1 MCU PCB OFF MCU address setup ON Indoor unit Indoor unit address Branch part use setup 4 4 2 1 5 6 0 Branch A 4 B C D E 5...

Page 184: ...it display 1 How to check Check the number of indoor units connected to MCU then readjust the switch for the number of units After completing resetting press the outdoor unit s K3 button to reset or turn off to restart Indoor unit display MCU BOX 0 Outdoor unit PCB MCU PCB OFF MCU address setup Indoornumbersetup MCUnumbersetup ON Indoor unit address Branch part use setup 1 2 2 1 8 6 1 6 0 Branch A...

Page 185: ...ak away from the PCB Did the resistance value significantly stray from the following temperature table After separating the indoor temperature sensor connector from the PCB measure the resistance value between the terminals Restart operation after changing the PCB Restart operation after connecting the connector to the PCB Change this since it is the fault of the indoor temperature sensor itself Y...

Page 186: ...ture table to the next After separating the outdoor temperature sensor connector from the PCB measure the resis tance value between both terminals Restart after replacing the PCB Restart after connecting the connector to the PCB As it is due to a problem with the outdoor temperature sensor replace it Yes No No Yes Yes Temperature C Resistance KΩ 70 60 50 40 30 21 10 0 10 2 2 3 0 4 2 5 8 8 3 12 1 1...

Page 187: ...or break away from the PCB Did the resistance value significantly stray from the following temperature table After separating the outdoor COND OUT sensor connector from the PCB measure the resistance value between the two terminals Restart operation after changing the PCB Restart operation after connecting the connector to the PCB Change this part as it is the fault of the outdoor COND OUT sensor ...

Page 188: ...rmo On OK Error Content Outdoor COND Out sensor breakaway error Yes Yes Is the COND Out sensor and the sensor holder correctly attached Is the COND Out sensor resistance value reasonable ref E231 Are there any changes in the value of the sensor when operating from stop to heating Complete Re insert sensor Re attach sensor holder Yes No Faulty Sensor Sensor change No Blocked Sensor PATH Change heat...

Page 189: ... PCB Restart operation after connecting the connector to PCB Change this part as it is the fault of the discharge temperature sensor itself Yes No No Temperature C 130 120 100 80 60 25 20 10 0 Resistance KΩ 8 9 11 2 18 5 32 0 59 0 200 0 242 0 362 0 553 0 4 5 39 Digital Compressor Discharge Temperature Sensor Error OPEN SHORT Operation Reservation Blast Filter Defrost t JHJUBM DPNQSFTTPS EJTDIBSHF ...

Page 190: ...sor discharge temperature sensor break away from the PCB Did the resistance value significantly stray from the following temperature table Separate the connector for the outdoor constant rate compressor discharge temperature sensor from the PCB and measure the resistance value between the 2 terminals Restart operation after changing PCB Restart operation after connecting the connector to PCB Chang...

Page 191: ...he sensor Re attach the sensor holder Yes No Compressor non operation cause analysis No Faulty sensor Change the sensor No Outdoor Unit Display No 1 compressor for each outdoor unit Compressor No 2 Compressor No 3 Indoor Unit Display Operation Reservation Blast Filter Defrost Judgment Method 1 Current value of the relevant compressor CT sensor Value is 5A or more 2 Discharge Temperature of Relevan...

Page 192: ...ight before the start of compressor Tsump ini current compressor s SUMP temp Tsump real When the difference between Tsump ini and Tsump real is an absolute value so that it cannot be more than 2 C In other words the condition of Tsump real Tsump ini 2 C has been satisfied for 60 minutes since a compressor started it is diag nosed as an error After 60 minutes of compressor operation there will be n...

Page 193: ...c ini and the suction temperature of the current COMP is set at Tsuc real it is considered to have an error if the condition of Tsuc real Tsuc ini 2 C is maintained for 30 minutes t 4VDUJPO UFNQFSBUVSF TFOTPS CSFBLBXBZ GBVMUZ TFOTPS Outdoor Unit Display 1 Inspection Method Complete Is suction sensor and sensor Holder accurately attached Is suction sensor resistance value reasonable Ref E231 Faulty...

Page 194: ...ensor break away from the PCB Did the resistance value significantly stray from the following temperature table Separate the connector of the outdoor SUMP sensor from the PCB and measure the resistance value between the two terminals Restart operation after changing PCB Restart operation after connecting the connector to PCB Change this part as it is the fault of the outdoor SUMP sensor itself No ...

Page 195: ...ESET and only when set is stopped 2 An OPEN SHORT error will occur if the input voltage standard range of 0 5V 4 95V is exceeded 1 Inspection Method Did the high pressure connector get disconnected from the PCB Out of the PCB high pressure sensor terminals is there voltage between pins 3 and 4 5V Replace high pressure sensor Is there refrigerant inside the set Please check by connecting the menu f...

Page 196: ...ESET and only when set is stopped 2 An OPEN SHORT error will occur if the input voltage standard range of 0 5V 4 95V is exceeded 1 Inspection method Did the low pressure connector get disconnected from the PCB Out of the PCB low pressure sensor terminals is there voltage between pins 3 and 4 5V Replace low pressure sensor Is there refrigerant inside the set Please check by connecting the menu fold...

Page 197: ...ensor break away from the PCB Did the resistance value significantly stray from the following temperature table Separate the connector of the outdoor oil balance sensor from the PCB and measure the resistance value between the two terminals Restart operation after changing PCB Restart operation after connecting the connector to PCB Change this part as it is the fault of the outdoor oil balance sen...

Page 198: ...sensor break away from the PCB Did the resistance value significantly stray from the following temperature table Separate the connector of the outdoor suction sensor from the PCB and measure the resistance value between the 2 terminals Restart operation after changing PCB Restart operation after connecting the connector to PCB Change this part as it is the fault of the outdoor suction sensor itsel...

Page 199: ...sor break away from the PCB Did the resistance value significantly stray from the following temperature table Separate the connector of the liquid pipe temperature sensor from the PCB and measure the resistance value between the two terminals Restart operation after changing PCB Restart operation after connecting the connector to PCB Change this part as it is the fault of the liquid pipe temperatu...

Page 200: ...nector correctly connected to PCB Can you hear the valve operating sound when power on Is the connector of sol valve coil correctly connected Replace sol valve body Check and restart the connector No Yes No Yes No Yes Check and reassemble the coil Restart the set and check if there is error 9 6 B B a LQGG ...

Page 201: ... IN sensor break away from the PCB Did the resistance value significantly stray from the following temperature table Separate the connector of the EVI IN sensor from the PCB and measure the resistance value between the 2 terminals Restart operation after changing PCB Restart operation after connecting the connector to PCB Change this part as it is the fault of the outdoor EVI IN sensor itself No N...

Page 202: ...I OUT sensor break away from the PCB Did the resistance value significantly stray from the following temperature table Separate the connector of the EVI OUT sensor from the PCB and measure the resistance value between the 2 terminals Restart operation after changing Restart operation after connecting the connector to PCB Change this part as it is the fault of the outdoor EVI OUT sensor itself No N...

Page 203: ... 2 sensor break away from the PCB Did the resistance value significantly stray from the following temperature table Separate the connector of the Suction 2 sensor from the PCB and measure the resistance value between the two terminals Restart operation after changing PCB Restart operation after connecting the connector to PCB Change this part as it is the fault of the outdoor Suction 2 sensor itse...

Page 204: ...BNPVOU Judgment Method t 7BMVF PG UIF IJHI QSFTTVSF TFOTPS JT EFUFDUFE BU LH DN PS NPSF Outdoor Unit Display Is the S net estimated value and the Manifold Gauge value in accordance Are the indoor unit and outdoor unit EEVs normally operating Are there any clogs inside the pipe e g filter Check the refrigerant amount Are the outdoor fan operating normally for the air conditioning and the indoor fan...

Page 205: ... Judgment Method t OTQFDUJPO XIFO UIF WBMVF PG MPX QSFTTVSF TFOTPS JT LH DN or less for air conditioning and 1 4 kg cm or less for heating Outdoor Unit Display 1 Inspection Method Are the S net estimated value and the Manifold Gauge value in accordance Are the indoor unit and outdoor unit EEVs normally operating Are there any clogs inside the pipe e g filter Check the refrigerant amount Is there a...

Page 206: ...pressor Refer to the solution method for the liquid compression prevention error E477 Re connect and check the connector Yes Yes Yes No No Re attach and check sensor Check by referring to the other temperature sensor problem check up methods Outdoor Unit Display Indoor Unit Display Operation Reservation Blast Filter Defrost Judgment Method t BJOUBJO TVNQ UFNQFSBUVSF PG PS NPSF GPS GJWF NJOVUFT Spe...

Page 207: ...PU HP FOE PVUEPPS VOJU Judgment Method t 8IFO WBMVF PG DPNQSFTTPS EJTDIBSHF UFNQFSBUVSF TFOTPS JT DIFDLFE BU PS NPSF Outdoor Unit Display 1 Inspection Method Is the resistance value normal for the compressor discharge temperature sensor Refer to item E251 Test Operation Are all service valves open Are the indoor unit and outdoor unit EEVs normally operating Are there any clogs inside the pipe e g ...

Page 208: ...F DJSDVJU wave orders are compared E425 is automatically cancelled when the phase power is restored to normal Indoor Unit Display Judgment Method Special Cause Outdoor Unit Display Check the voltage for the major parts Is the voltage of the CN82 wire between Red White White Black Red Black around AC 380V Turn off the power circuit breaker exchange two cables out of the three cables of the 3 phase ...

Page 209: ... JT NBJOUBJOFE GPS NJOVUFT PS NPSF Outdoor Unit Display 1 Inspection Method No Is the S net estimated value and the Manifold Gauge value in accordance Is the indoor unit and outdoor unit EEV operating normally Are there any clogs inside the pipe e g filter Check the refrigerant amount Test Operation Please open service valve Change low pressure sensor Check relevant EEV Pipe Inspection Yes Yes Yes...

Page 210: ...balance operation and the hot gas by pass is opened 4 Error displayed if the temperature does not change by 7 C when Oil Balance Valve 1 is opened and the hot gas bypass is opened during the process of discharging the oil under oil balance operation Outdoor Unit Display 1 Inspection Method Change the coil Is the resistance value for c oil reasonable Did Oil Valve 1 temperature sensor break away Ch...

Page 211: ...rmal the EVA IN and OUT temperatures for the blast may rise If air conditioning is operated for low temperature with excessive refrigerant amount then the DSH may descend Check refrigerant amount No Reconnect connector Yes No Reassemble coil Yes Breakdown Change super cooler Normal No Change liquid bypass valve Yes Breakdown Change indoor unit EEV Normal Reinstall pipe Breakdown Change EVI EEV Nor...

Page 212: ...f the input voltage standard ranges of 0 5V 4 95V of both the high and low pressure sensors are exceeded 3 Will occur if the measured value of both high and low pressure sensors is 1kgf cm G 1 Inspection method Did the high low pressure connector get disconnected from the PCB Out of the PCB high pressure sensor terminals is there voltage between pins 3 and 4 5V Replace high low pressure sensor Is ...

Page 213: ...ts the operation in outdoor temperature over 15 C Outdoor unit display 1 How to check The above error code is not caused by a product s problem but a function to protect the product by limiting the available tempera ture range so please refer to the usable temperature range in the product manual If the error code is displayed despite a condition that does not belong to any of the above diagnosis m...

Page 214: ...nd check connector No No Yes Yes Supplement or recharge the refrigerant Outdoor Unit Display Indoor Unit Display Operation Reservation Blast Filter Defrost Judgment Method t 0QFSBUJPO TIPVME CF GPSCJEEFO JG UIF IJHI QSFTTVSF TFOTPS WBMVF PG UIF NBJO VOJU CFGPSF UIF QVNQ EPXO JT started at 3 1kg cm G or below for air conditioning and 2 6kg cm G or less for heating for three consecutive seconds Rest...

Page 215: ...display E445 Outdoor Unit Display Indoor Unit Display Judgment Method t 3FGFS UP UIF KVEHNFOU NFUIPE CFMPX Special Cause t POOFDUPS 1 JT OPU DPOOFDUFE 4VNQ TFOTPS DPNQSFTTPS TFQBSBUFE 0XO QSPCMFN PG No Connect CCH connector to PCB Is the CCH connector connected to PCB Yes No Attach the sump sensor to the lower part of the compressor Is the sump sensor attached to the lower part of the compressor Y...

Page 216: ...oor Fan Motor t OEPPS GBO NPUPS MPDL PS EFGFDU t 8IFO BO PQFSBUJOH PVUEPPS GBO NPUPS JT PWFSIFBUFE GPS NPSF UIBO Indoor unit display Criteria Cause of problem Outdoor unit display 1 How to check 1 As it is a function that is programmed to protect overheating or motor protection lower the rotational frequency of the motor to cool it down there would be no problem as long as the motor operates 2 Che...

Page 217: ...ompared to the instructed value Indoor Unit Display Judgment Method Special Cause Outdoor Unit Display 1 Inspection Method No Yes No Yes No Yes No Yes Connect connector as normal Is connection for feedback connector normal Re connect connector Is the connection for the fan connector normal Re connect connector Is connection for fan power condenser normal Complete Is the motor operating condition n...

Page 218: ...istance DVM 4 Small chassis RD080 100 120 X Relevant Code DB31 00330D 1 Motor Condition Inspection before Changing Motors 1 Take out the motor connector of the outdoor unit and measure the resistance of each phase PSNBM 6 7 7 8 8 6 Ʈ FBDI Faulty Short below 4Ω Open cannot be measured 2 Check Motor Sensor hall sensor With the motor motor sensor connector connected to the BLDC drive PBA input the po...

Page 219: ...eed to check if there is a problem with fan load status 4 5 70 Counter Rotation Error of an Outdoor Fan Motor t VF UP XJOE UIBU DBO SVO UIF GBO DPVOUFS XJTF t 8IFO UIF SPUBUJPOBM EJSFDUJPO PG BO PVUEPPS GBO NPUPS JT DPVOUFS DMPDLXJTF CFGPSF PQFSBUJOH Indoor unit display Criteria Cause of problem Outdoor unit display 1 How to diagnose 1 Check if the start instruction of outdoor unit s fan is counte...

Page 220: ...t Method Special Cause Outdoor Unit Display 1 Inspection Method Is the CT sensor connector resistance normal Are all the CT values 0 when the compressor is stopped Is the CT value measured at 20A or more during the operation Is the measured value from the separate ammeter the same as the CT sensor value Test Operation Inspection Complete Change CT sensor Change CT sensor Change CT sensor Breakdown...

Page 221: ...mpression is effective when the relevant compressor is operating If there is no compression then this is a compressor breakdown Is the CT sensor connector resistance normal Are all the CT values 0 when the compressor is stopped Is the compressor still not operating even when a magnetic contactor is connected Is the measured value from the separate ammeter the same as the CT sensor value Test Opera...

Page 222: ...ange the discharge valve leakage Re check the sensor connection attachment No Normal Normals Yes Breakdown Breakdown Resolve the relevant EEV problem Resolve the relevant valve problem Outdoor Unit Display Indoor Unit Display Judgment Method t 46 1 UFNQFSBUVSF EFDSFBTF 4 NJO Special Cause t 7 7 BOE TVQFS DPPMFS MJRVJE CZQBTT WBMWF MFBLBHF SFGSJHFSBOU PWFSDIBSHF JOEPPS VOJU 7 MFBLBHF direct connect...

Page 223: ...ust on the surface of the coil of an electronic expansion valve with the naked eye and then check the resistance between each terminal to find any wire breaking or short circuit 4 Press the RESET KEY K3 of the outdoor unit then see if the same error occurs 4 In case of closure problem operate the indoor unit in which the error has occurred 4 In case of opening problem please do not operate the ind...

Page 224: ...re is any rust on the surface of the coil of an electronic expansion valve with the naked eye and then check the resistance between each terminal to find any wire breaking or short circuit 4 Press the RESET KEY K3 of the outdoor unit then see if the same error occurs 2 In case of closure problem operate the indoor unit in which the error has occurred 2 In case of opening problem please do not oper...

Page 225: ...n Method Is the electronic expansion valve wire connected to the PCB After measuring the coil terminal resistance is there a disconnection or short circuit inside the coil Is the electronic expansion valve coil connected to the main body properly After Resetting the outdoor unit does an error occur even after running it again with the same combination Connect to PCB and run again No No Yes No No Y...

Page 226: ...ere error occurred 1 Inspection Method Is the electronic expansion valve wire connected to the PCB After measuring the coil terminal resistance is there a disconnection or short circuit inside the coil Is the electronic expansion valve coil connected to the main body properly After Resetting the outdoor unit does an error occur even after running it again with the same combination Connect to PCB a...

Page 227: ...MEMO Samsung Electronics 4 136 9 6 B B a LQGG ...

Page 228: ...5 1 Samsung Electronics 5 Exploded Views and Parts List 5 1 Indoor Unit 5 1 1 Slim1 way cassette type Body 9 6 B B a LQGG ...

Page 229: ...17 DB67 00833A DRAIN PUMP PBT 1 0 WHITE 1 SA 18 DB69 00137A BAND RING STS304 T1 5 PI14 1 SNA 19 DB73 00390B RUBBER BASE PUMP NBR 30 BLK 1 SNA 20 DB73 00391B RUBBER CAP PUMP NBR 30 BLK 1 SNA 21 DB63 01699A COVER PUMP ABS 2 5 78 100 GRAY 1 SNA 22 DB95 00131M ASS Y SENSOR FLOAT SLIM1WAY SmH250 02L 180mm RED BLK 1 SA 23 DB94 01367C ASS Y DRAIN PAN ASS Y 1 SA 24 DB73 00133B RUBBER CAP DRAIN SOCKET NBR ...

Page 230: ...Exploded Views and Parts List 5 3 Samsung Electronics Slim1 way cassette type ND0561 0711HXE Series Body 9 6 B B a LQGG ...

Page 231: ... 1 SA 16 DB67 00833A DRAIN PUMP PBT 1 0 WHITE 1 1 SA 17 DB69 00137A BAND RING STS304 T1 5 PI14 1 1 SNA 18 DB73 00494A RUBBER BASE PUMP NBR 30 32 5 BLK 1 1 SA 19 DB73 00391D RUBBER CAP PUMP NBR 30 BLK 1 1 SNA 20 DB63 02265A COVER PUMP ABS T2 0 82 5 40 5 WHT 1 1 SA 21 DB95 01359F ASS Y SENSOR FLOAT FLOAT SWITCH 8 5mm GAUSS 26G 180mm 1 1 SA 22 DB94 02299D ASS Y DRAIN PAN ASS Y 1 1 SA 23 DB73 00306A R...

Page 232: ...Exploded Views and Parts List 5 5 Samsung Electronics Slim 1 way cassette type cont Panel A type 9 6 B B a LQGG ...

Page 233: ... 437 BLK 1 SA 7 DB63 01695A FILTER AIR INLET G ABS 2 196 320 BLK 1 SA 8 DB63 01697A COVER DISPLAY PCB HIPS 2 5 117 154 BLK 1 SNA 9 DB64 00237A PANEL DISPLAY LED AKM 2800 PC 1 SA 10 DB64 01759A PANEL FRONT SLIM 1WAY ABS 40 465 1180 DA White 1 SNA 11 DB64 01760A WINDOW DISPLAY PCB PC 1 5 40 40 MILKY WHT 1 SNA 12 DB64 01762A GRILLE AIR INLET ABS 2 0 213 859 WHT 1 SA 13 DB65 00023A CLIP WIRE ASS Y NYL...

Page 234: ...xploded Views and Parts List 5 7 Samsung Electronics Slim 1 way cassette type ND0561 0711HXE Series cont Panel B type 22 21 20 19 11 24 6 8 1 10 23 24 15 18 24 17 16 14 13 3 12 2 5 7 9 25 9 6 B B a LQGG ...

Page 235: ... T10 32 87 1 SNA 11 DB62 07240A SEAL PANEL SIDE RH FOAM PE GRAY T10 32 84 1 SNA 12 DB66 01402A BLADE H ABS T2 0 68 3 WHT 1 SA 13 DB64 00237A PANEL DISPLAY LED PC 1 SA 14 DB64 01760A WINDOW DISPLAY PCB PC 1 5 40 40 MILKY WHT 1 SNA 15 DB63 02275A COVER DISPLAY PCB ABS T2 0 112 90 NATURAL 1 SA 16 DB93 07960A ASS Y PCB SUB DISPLAY ASS Y 1 SNA 17 DB61 03856A BRACKET MOTOR BLADE H SGCC M T1 50 33 7 NATU...

Page 236: ...ews and Parts List 5 9 Samsung Electronics 5 1 2 2 way cassette type Body 3 2 11 1 5 12 8 9 5 1 5 2 3 1 3 2 1 3 1 1 1 5 4 20 23 22 8 9 12 18 16 17 19 13 24 21 10 11 14 15 25 7 6 1 4 1 2 1 7 1 6 1 8 9 6 B B a LQGG ...

Page 237: ... HOLDER COVER SIDE LF ASS Y EVAP ASS Y EVAP ASS Y TUBE COLLECTOR ASS Y TUBE COLLECTOR ASS Y INLET PART ASS Y INLET PART ASS Y C F FAN MOTOR ASS Y ASS Y COVER MOTOR ASS Y CASE MOTOR ASS Y SENSOR FLOAT ASS Y COVER EVAP GUIDE ASS Y CASE FAN SIDE SUB ASS Y BEARING GUIDE CONTROL DRAIN PUMP HOLDER DRAIN PUMP RUBBER DRAIN PUMP ASS Y DRAIN SOCKET BAND RING CUSHION BODY CLIP BRUSH CABINET BASE CABI SIDE RH...

Page 238: ...Exploded Views and Parts List 5 11 Samsung Electronics 2 way cassette type cont Panel 18 13 7 11 12 2 3 17 15 16 19 9 6 10 8 20 1 14 4 5 9 6 B B a LQGG ...

Page 239: ... 01666A DB39 00875A DB64 00745A DB64 00746A DB61 01238A PANEL FRONT GRILLE FRONT FILTER INLET AIR CASE OUTLET AIR BLADE H BLADE V LINK BLADE V LATCH DC COVER PANEL PLATE HANGER MOTOR STEP HOLDER MOTOR C W MOTOR STEP LONG C W MOTOR STEP SHORT PCB DISPLAY C W DISPLAY INLAY WINDOW INLAY BUTTON CASE LED PCB CABLE CLAMP ABS ABS ASS Y HIPS HIPS PP PP ASS Y HIPS STS304 ASS Y HIPS V0 BLK UL1007 UL1007 UL1...

Page 240: ...Exploded Views and Parts List 5 13 Samsung Electronics 5 1 3 4 way cassette type Body AVXC4H045 056 071 090E ND045 056 071 0904H 9 6 B B a LQGG ...

Page 241: ...M 2 2 SNA 10 DB90 02692A ASS Y COVER PIPE ASS Y 1 1 SNA 11 DB90 03189A ASS Y CABI FEONT ASS Y SGCC M 1 1 SNA 12 DB90 01950B ASS Y COVER DRAIN PUMP ASS Y 1 1 SNA 13 DB94 01389A ASS Y HOSE DRAIN ASS Y 1 1 SNA 14 DB61 03093A HOLDER EVAP STS301 2 2 SNA 15 DB96 08027B ASS Y EVAP UNIT ASS Y 1 SNA DB96 08027A ASS Y EVAP UNIT ASS Y 1 SNA 16 DB90 03190A ASS Y CABI BACK ASS Y SGCC M 1 1 SNA 17 DB90 02090B S...

Page 242: ...CC M 2 2 SNA 10 DB90 02692A ASS Y COVER PIPE ASS Y 1 1 SNA 11 DB90 03189A ASS Y CABI FEONT ASS Y SGCC M 1 1 SNA 12 DB90 01950B ASS Y COVER DRAIN PUMP ASS Y 1 1 SNA 13 DB94 01389A ASS Y HOSE DRAIN ASS Y 1 1 SNA 14 DB61 03093A HOLDER EVAP STS301 2 2 SNA 15 DB96 08027B ASS Y EVAP UNIT ASS Y 1 SNA DB96 08027A ASS Y EVAP UNIT ASS Y 1 SNA 16 DB90 03190A ASS Y CABI BACK ASS Y SGCC M 1 1 SNA 17 DB90 02090...

Page 243: ...MEMO Samsung Electronics 5 16 9 6 B B a LQGG ...

Page 244: ...Exploded Views and Parts List 5 17 Samsung Electronics 4 way cassette type cont Body AVXC4H 112 128 140E ND112 128 1404H 9 6 B B a LQGG ...

Page 245: ...LOCK 4P TERMINAL BLOCK 6P HOLDER SENSOR REUSABLE CABLE TIES ASS Y CUSHION DRAIN BRACKET WASHER FAN ASS Y FAN TURBO CABI SIDE ASS Y COVER SIDE ASS Y CABI FRONT ASS Y COVER DRAIN PUMP ASS Y HOSE DRAIN HOLDER EVAP ASS Y EVAP UNIT ASS Y EVAP UNIT ASS Y CABI BACK SCREW PUMP ASS Y DRAIN PUMP SWITCH FLOAT RUBBER PUMP BRACKET DRAIN PUMP DRAIN PUMP CLIP BRUSH ASS Y CUSHION BASE MOTOR INDOOR ASS Y BRACKET M...

Page 246: ...4P TERMINAL BLOCK 6P HOLDER SENSOR REUSABLE CABLE TIES ASS Y CUSHION DRAIN BRACKET WASHER FAN ASS Y FAN TURBO CABI SIDE ASS Y COVER SIDE ASS Y CABI FRONT ASS Y COVER DRAIN PUMP ASS Y HOSE DRAIN HOLDER EVAP ASS Y EVAP UNIT ASS Y EVAP UNIT ASS Y CABI BACK SCREW PUMP ASS Y DRAIN PUMP SWITCH FLOAT RUBBER PUMP BRACKET DRAIN PUMP DRAIN PUMP CLIP BRUSH ASS Y CUSHION BASE MOTOR INDOOR ASS Y BRACKET MOTOR ...

Page 247: ...MEMO Samsung Electronics 5 20 9 6 B B a LQGG ...

Page 248: ...Exploded Views and Parts List 5 21 Samsung Electronics 4 way cassette type cont Panel 10 11 22 23 17 18 24 19 28 12 3 27 13 21 26 25 20 2 1 9 7 8 6 5 4 16 15 14 9 6 B B a LQGG ...

Page 249: ... KNOB SLIDE A KNOB SLIDE B SPRING KNOB COVER KNOB CORNER COVER CORNER COVER PCB COVER PCB LINK MOTOR A LINK MOTOR B HOLDER LINK BLADE LINK BLADE LINK UNIVERSAL JOINT JOINT UNIVERSAL COVER SIDE A COVER SIDE B COVER SIDE C COVER SIDE D INLAY PCB BUTTON PCB CUSHION IN CUSHION OUT BRACKET STEPPING MOTOR PLATE HANGER ASS Y PCB DISPLAY HF ABS Korea PBT 20 GF Korea HF ABS Korea P P BLK 40 HF ABS Korea HF...

Page 250: ...Exploded Views and Parts List 5 23 Samsung Electronics 31 8 15 16 12 16 11 17 21 5 4 1 2 9 10 6 18 7 3 14 13 20 19 24 26 27 28 29 30 23 25 22 33 32 5 1 4 Mini 4 way cassette type Body 9 6 B B a LQGG ...

Page 251: ...OLE ASS Y COVER PIPE HOLDER EVAP ASS Y DRAIN HOSE ASS Y COVER DRAIN GUIDE EVAP ASS Y EVAP UNIT PUMP DRAIN RUBBER PUMP BRACKET PUMP ASS Y BASE CUSHION MOTOR FAN BRACKET MOTOR IN GROMMET MOTOR ASS Y CABI BASE GUARD SAFETY THERMISTOR EVAP IN ASS Y DRAIN HOSE INSTALL ABS V0 T2 0 MINI 4WAY CASSETTE 1 L 2 N Vc Vc F1 F2 V1 V2 F3 F4 450VAC 3 5uF SGCC M T1 0 103AT 20 100ÞC ABS V0 T2 0 MINI 4WAY CASSETTE SA...

Page 252: ...Exploded Views and Parts List 5 25 Samsung Electronics Mini 4 way cassette type cont Panel 30 19 2 15 3 17 27 18 31 13 1 14 9 20 22 21 32 8 29 7 6 11 25 26 16 10 12 24 23 4 5 33 28 9 6 B B a LQGG ...

Page 253: ...NI POM NTR 8 SA 15 DB65 10074D CLAMP CABLE DA 4N 2 SA 16 DB65 00023A CLIP WIRE ASS Y L130mm 1 SA 17 DB63 01364A COVER A ABS V0 BLK 1 SA 18 DB63 01366A COVER B ABS V1 BLK 2 SA 19 DB63 01377A COVER C ABS V2 BLK 1 SA 20 DB63 01036A COVER KNOB HIPS UL94 HB WHT 2 SA 21 DB64 01145A KNOB SLIDE HIPS 94HB HG 0760 WHT 2 SA 22 DB67 00030A SPRING KNOB STS304 T0 5 2 SA 23 DB69 01269A CUSHION IN EPS 30 4 SA 24 ...

Page 254: ...Parts List 5 27 Samsung Electronics 23 8 13 9 14 2 16 18 17 1 6 15 21 11 24 25 4 5 22 26 10 3 8 7 19 20 23 6 23 4 23 5 23 3 23 7 23 1 23 8 23 2 12 5 1 5 Duct type Slim I AVXDSH022 028 036E ND022 028 036LHXE 9 6 B B a LQGG ...

Page 255: ...A ASS Y SUPPORT EVAP RH ASS Y 1 1 1 SA 15 DB94 00768A ASS Y PARTITION ASS Y 1 1 1 SA 16 DB61 02282A BRACKET MOTOR SGCC M T2 0 1 1 1 SA 17 DB99 00669A BAND MOTOR SINYA 4 4 4 SA 18 DB31 00312A MOTOR SINYA SSR PID 1 1 1 SA 19 DB67 00565A BLOWER ASS Y ABS TORSIONAL BUSH 2 2 2 SA 20 DB90 01947A ASS Y CASE BLOWER UPPER ASS Y 2 2 2 SA 21 DB90 01948A ASS Y CASE BLOWER BOTTOM ASS Y 2 2 2 SA 22 DB94 01007B ...

Page 256: ...t 5 29 Samsung Electronics 5 1 6 Duct type Slim II AVXDSH045 056 071E ND045 056 071LHXE 8 10 9 35 13 11 32 16 22 21 27 28 20 23 24 19 17 3 18 26 25 5 8 4 30 30 1 30 6 30 5 30 2 33 30 4 30 3 12 29 6 7 14 31 15 2 1 34 9 6 B B a LQGG ...

Page 257: ...2A BRACKET MOTOR SGCC M T2 0 1 1 SA 18 DB97 03800A BAND MOTOR SINYA 1 1 SA 19 DB31 00314C MOTOR SINYA 60Hz 1 1 SA 20 DB66 01007A MOTOR SHAFT SINYA 1 1 SNA 21 DB94 00759A MOLD BEARING ASS Y 1 1 SA 22 DB67 00581A CAP BEARING SGCC M T0 8 1 1 SNA 23 DB73 00285A RUBBER SHAFT CR V0 1 1 SNA 24 DB96 04902A COUPLER ASS Y 1 1 SA 25 DB67 00565A BLOWER A ASS Y ABS 1 1 SA 26 DB67 00576A BLOWER B ASS Y ABS 2 2 ...

Page 258: ...ng Electronics 5 1 7 Duct type Slim III AVXDSH090 112 128 140E ND090 112 128 140LHXE 8 10 9 33 13 11 32 16 22 21 27 28 20 23 24 19 17 3 18 26 25 5 8 4 30 30 1 30 4 30 7 30 6 30 2 30 3 30 5 30 9 30 8 12 29 6 7 34 14 31 15 2 1 35 9 6 B B a LQGG ...

Page 259: ... 1 SA 17 DB61 02331A BRACKET MOTOR SGCC M T2 5 1 1 SA 18 DB97 03751A BAND MOTOR SINYA 1 1 SA 19 DB31 00427A MOTOR SINYA SSR 1 1 SA 20 DB81 00617A MOTOR SHAFT SINYA 1 1 SA 21 DB94 00759A MOLD BEARING ASS Y 1 1 SA 22 DB67 00581A CAP BEARING SGCC M T0 8 1 1 SA 23 DB73 00285A RUBBER SHAFT CR V0 1 1 SA 24 DB96 04902A COUPLER ASS Y 1 1 SA 25 DB67 00583A BLOWER A ASS Y 1 1 SA 26 DB67 00583B BLOWER B ASS ...

Page 260: ...d Views and Parts List 5 33 Samsung Electronics 12 17 2 16 5 3 9 6 14 15 13 1 14 1 14 3 14 2 14 6 14 5 14 4 14 7 14 8 23 21 18 20 19 22 4 8 11 10 7 5 1 8 Duct type MSP AVXDUH056 071E ND056 071SH 9 6 B B a LQGG ...

Page 261: ...VXDUH071E 1 SNA DB96 10906B ASS Y EVAP UNIT AVXDUH056E 1 SNA 14 DB93 03364B ASS Y CONTROL IN ASS Y 1 1 SNA 14 1 DB90 02981B ASS Y CASE CONTROL ASS Y 1 1 SA 14 2 DB61 02287A CASE PCB ABS V0 T2 5 1 1 SA 14 3 DB26 00080A TRANS POWER AC 230V 50HZ 1 1 SA 14 4 2301 001381 C FILM LEAD OTHER 8000nF 450V BK 1 1 SA 14 5 DB65 00105L TERMINAL BLOCK DAF S6P 1 1 SA 14 6 DB65 00105M TERMINAL BLOCK DAF S6P 1 1 SA...

Page 262: ... Views and Parts List 5 35 Samsung Electronics AVXDUH090E ND090SH 10 11 15 3 14 7 14 8 14 4 15 2 15 9 15 6 15 1 15 5 15 4 15 7 15 8 1 13 12 9 4 7 11 15 10 8 2 14 5 6 2 3 14 6 14 1 14 2 14 3 14 5 9 6 B B a LQGG ...

Page 263: ...43A BRACKET FILTER SGCC M T0 8 4 SA 10 DB32 00142B THERMISTOR IN 10Kohm 103AT 1 SA 11 DB63 01657A COVER CONTROL mA0 DUCT SGCC M T0 8 1 SA 12 DB63 01657A FILTER PRE ASS Y T4 5 NATURE 1 SA 13 DB96 10905A ASS Y EVAP UNIT AVXDUH090E 1 SA 14 DB94 01274A ASS Y FAN IN PARTS H094EAMC 220 240V 1 SA 14 1 DB90 02926A ASS Y CABI FRONT mA0 PJT SSEC 1 SA 14 2 DB90 03030A ASS Y BRACKET OUTLET PART H094EAMC SSEC ...

Page 264: ...d Views and Parts List 5 37 Samsung Electronics AVXDUH112E ND112SH 12 4 10 2 7 11 15 3 16 14 1 9 6 5 13 17 8 14 8 14 7 14 6 14 1 14 5 15 3 15 1 15 2 15 9 15 6 15 8 15 7 15 4 15 5 14 3 14 4 14 2 9 6 B B a LQGG ...

Page 265: ...1 SNA 14 1 DB90 02402A ASS Y CABI FRONT ASS Y SGCC M T1 5 1 SNA 14 2 DB90 02408A ASS Y BRACKET OUTLET PART ASS Y SGCC M T1 0 1 SA 14 3 DB61 02331A BRACKET MOTOR ASS Y SGCC M T2 5 1 SNA 14 4 DB72 03751A BAND MOTOR ASS Y SGCC M T1 6 4 SA 14 5 DB61 02333A CASE FAN LOW ASS Y ABS GF10 T3 0 2 SA 14 6 DB61 02332A CASE FAN UP ASS Y ABS GF10 T3 0 2 SA 14 7 DB67 00583B BLOWER ASS Y ABS GF10 OD230 2 SA 14 8 ...

Page 266: ...rts List 5 39 Samsung Electronics AVXDUH128 140E ND128 140SH 1 5 6 15 16 9 8 10 4 14 13 7 18 20 2 3 17 12 11 17 8 17 4 17 10 17 6 17 3 17 9 17 7 17 1 17 2 18 1 18 8 18 4 18 7 18 2 18 5 17 5 18 6 18 9 19 18 3 9 6 B B a LQGG ...

Page 267: ...DB94 01370A ASS Y BLOWER ASS Y 1 SNA 17 1 DB90 02028A ASS Y CABI FRONT ASS Y SGCC M T1 5 1 SNA 17 2 DB90 02013A ASS Y BRACKET OUTLET PART ASS Y SGCC M T1 0 1 SA 17 3 DB61 02372A BASE MOTOR ASS Y SGCC M T2 5 1 SNA 17 4 DB61 02375A BRACKET MOTOR ASS Y SGCC M T2 5 1 SNA 17 5 DB72 00710A BAND MOTOR ASS Y SGCC M T1 6 4 SA 17 6 DB61 00540B BRACKET MOTOR GUIDE ASS Y SGCC M T1 6 1 SNA 17 7 DB61 02382A CAS...

Page 268: ...iews and Parts List 5 41 Samsung Electronics 5 1 9 Duct type HSP ND140HHXEA 1 2 3 4 5 6 7 8 10 11 13 12 9 14 1 14 2 14 15 16 18 16 11 16 1 16 2 16 3 16 4 16 5 16 6 16 8 16 9 16 10 17 15 1 15 2 16 7 9 6 B B a LQGG ...

Page 269: ...1371A CABINET TOP DUCT 60K SGCC M T1 0 710 1240 SSEC 1 SA 15 DB90 02007B ASSY CABINET BOTTOM DRAIN HH175EZMC SSEC 1 SA 15 1 DB61 02374A BRACKET FILTER DUCT 60K SGCC M T1 0 50 250 SSEC 1 SA 15 2 DB64 01367A CABINET BOTTOM DRAIN DUCT 60K SGCC M T1 0 310 7 1240 SSEC 1 SA 16 DB93 10768A ASSY CONTROL IN HP HSP DUCT 1 SA 16 1 DB90 01992C ASSY CASE CONTROL NS140HHXEA SSEC 1 SA 16 2 DB26 00107A TRANS POWE...

Page 270: ...Exploded Views and Parts List 5 43 Samsung Electronics 5 1 10 Duct type SUPER Body _ _ 9 6 B B a LQGG ...

Page 271: ...A ASS Y BLOWER AL5052P 1 1 SA 7 3 DB31 00552F MOTOR FAN RH OSME 4904SAC 1 SA DB31 00552G MOTOR FAN RH OSME 4904SAC 1 SA 8 DB96 13201A ASS Y EVAP UNIT ASS Y 1 1 SA 8 1 DB96 12781A ASS Y EVAP SUB ASS Y 1 1 SA 8 2 DB96 12776A ASS Y COLLECTOR OUT ASS Y 1 1 SNA 8 3 DB96 13034A ASS Y VALVE EEV ASS Y 1 1 SNA 8 4 DB96 13197A ASS Y TUBECAPILLARY ASS Y 1 1 SNA 9 DB94 02452A ASS Y DRAIN PAN ASS Y SGCC M T1 4...

Page 272: ...Exploded Views and Parts List 5 45 Samsung Electronics Duct type SUPER cont Ass y Control In 9 6 B B a LQGG ...

Page 273: ... 8 6002 001149 SCREW TAPPING TH 2S M4 L12 DACRO SWRCH18A 8 SNA 9 6002 000535 SCREW TAPPING PH 2S M4 L8 ZPC WHT STS304 2 SA 10 6002 000548 SCREW TAPPING TH 2S M4 L25 ZPC WHT STS304 4 SNA 11 DB91 00309A SCREW TAPPING PH M3 L20 ZPC YEL 1 SNA 12 DB61 03922A SUPPORT PCB ABS 4 SNA 13 DB61 04023A SUPPORT SPACER DONG A DASS 13N 1 SA 14 DB65 00182B TERMINAL BLOCK L N 1 SNA 15 DB65 00277A TERMINAL BLOCK F1 ...

Page 274: ...s and Parts List 5 47 Samsung Electronics 5 1 11 Big Duct Body 2 11 1 1 4 3 5 6 12 9 8 10 7 11 11 2 11 3 11 4 11 5 11 6 2 1 2 2 6 9 6 1 6 6 6 10 6 8 6 3 6 7 6 4 6 2 6 5 5 1 5 2 5 3 4 2 4 1 4 4 4 3 4 5 9 6 B B a LQGG ...

Page 275: ...A 5 2 DB63 03007A COVER PIPE SGCC 1 1 1 SNA 5 3 DB61 04984A BRACKET CONTROL BASE SGCC 1 1 1 SNA 6 DB93 11723B ASS Y CONTROL IN 1 1 1 SNA 6 1 DB90 06715A ASS Y CASE CONTROL SGCC 1 1 1 SNA 6 2 DB63 03004A COVER CONTROL SGCC 1 1 1 SNA 6 3 DB26 00095A TRANS POWER 1 1 1 SA 6 4 DB27 00093A COIL CHOKE REACTOR 1 1 1 SA 6 5 DB61 00250A HOLDER WIRE 2 2 2 SNA 6 6 DB93 12654A ASS Y PCB MAIN IN 1 1 1 SA 6 7 DB...

Page 276: ...t 5 49 Samsung Electronics 5 1 12 Ceiling type 14 7 43 37 29 4 23 18 6 41 40 36 34 32 1 38 19 20 16 24 42 13 15 39 30 26 28 27 3 25 46 33 44 1112 22 21 17 8 31 35 2 5 9 10 45 45 6 45 1 45 2 45 8 45 7 45 3 45 4 45 5 9 6 B B a LQGG ...

Page 277: ...31 00158A BLADE V ABS 12 12 19 DB31 00159A BLADE CONNECTOR V ABS 2 2 20 DB31 00164A BLADE CONNECTOR H ABS 2 2 21 DB31 00157A BLADE H ABS 1 1 22 DB31 10113A SWING MOTOR IN ASS Y 1 1 23 DB61 01352A BRACKET DRAIN SGCC M 1 1 24 DB67 00258A DRAIN SUB LF SGCC M 1 1 25 DB67 00259A DRAIN SUB RH ABS 1 1 26 DB96 07272B EVAPORATOR ASS Y 1 1 27 DB96 07656A ASS Y COLLECTOR ASS Y 1 DB96 07656B ASS Y COLLECTOR A...

Page 278: ... V0 1 1 45 DB93 05193B ASS Y CONTROL IN ASS Y 1 DB93 05193A ASS Y CONTROL IN ASS Y 1 45 1 DB61 01154A BASE CONTROL SGCC M 1 1 45 2 DB61 01220A CASE PCB MAIN ABS UL94 V0 1 1 45 3 DB93 05982C CEILING EU PCB ASS Y PCB 1 1 45 4 DB65 00105M TERMINAL BLOCK 6P DAF S6P 1 1 45 5 DB95 01101B TERMINAL BLOCK 6P DAF S6P 1 1 45 6 DB26 00080A TRANS POWER ASS Y 1 1 45 7 2301 001368 CAPACITOR 5uF 450VAC 1 2301 001...

Page 279: ...MEMO Samsung Electronics 5 52 9 6 B B a LQGG ...

Page 280: ...ist 5 53 Samsung Electronics 5 1 13 Console type 35 28 2 3 26 34 32 27 19 29 33 23 15 12 18 14 16 17 21 13 31 9 6 22 7 10 11 8 5 25 4 24 30 1 20 35 1 35 8 35 9 35 2 35 3 35 4 35 5 35 6 35 7 35 13 35 12 35 11 35 10 9 6 B B a LQGG ...

Page 281: ...DB31 00371A MOTOR STEP ABS V0 1 1 SA 23 DB31 00370A MOTOR STEP ABS V0 1 1 SA 24 DB90 03823A ASS Y HALF MIRROR DISPLAY PMMA 1 1 SA 25 DB61 01477A MAGNET 20x10x3 Gauss 2 400 2 600 1 1 SA 26 DB93 04230A COMPACT MPI 1 1 SA 27 DB96 09935A ASS Y EVAP ASS Y 1 SA DB96 09935B ASS Y EVAP ASS Y 1 SA 28 DB61 03542A BRACKET PIPE PP 1 1 SA 29 DB31 00507A FAN TURBO SAN GP20 ø40 H76 1 1 SA 30 DB70 00923A PLATE ST...

Page 282: ... Samsung Electronics 2 1 10 9 15 14 12 11 13 3 4 5 2 1 3 2 3 3 3 5 3 9 3 8 3 4 1 4 1 3 1 1 1 2 3 4 1 3 7 3 1 3 6 2 2 8 3 8 8 8 1 8 9 8 7 8 2 8 4 8 6 8 6 7 8 5 5 1 14 Wall mounted type Montblanc AVXWBH028 036E ND028 036BH 9 6 B B a LQGG ...

Page 283: ...UTTON POWER PMMA 1 SNA 3 8 DB93 05779A ASS Y DISPLAY ASS Y 1 SNA 3 9 DB93 05778A ASS Y DISPLAY MPI ASS Y 1 SNA 4 DB90 03967A ASS Y COVER TERMINAL ASS Y 1 SA 5 DB67 00849A CAP SCREW HIPS 2 SA 6 DB93 05899A ASS Y CONTROL IN ASS Y 1 SA 7 DB63 01850A COVER PBA SGCC M 1 SA 8 DB94 01557A ASS Y TRAY DRAIN ASS Y 1 SA 8 1 DB63 01849A TRAY DRAIN ABS 1 SNA 8 2 DB63 01837A TRAY STABILIZER ABS 1 SA 8 3 DB61 03...

Page 284: ...Exploded Views and Parts List 5 57 Samsung Electronics AVXWBH056 071E ND056 071BH 2 4 5 16 6 7 11 14 15 12 10 9 17 13 2 2 2 1 3 2 1 4 1 3 3 1 1 1 1 2 8 3 8 1 8 2 8 4 8 6 8 8 5 3 1 9 6 B B a LQGG ...

Page 285: ... TERMINAL ASS Y 1 SA 5 DB67 00855B CAP SCREW HIPS 3 SA 6 DB93 05894A ASS Y CONTROL IN ASS Y 1 SA 7 DB63 01859A COVER PBA SGCC M 1 SA 8 DB94 01549B ASS Y TRAY DRAIN ASS Y 1 SA 8 1 DB63 01853A TRAY DRAIN ABS 1 SNA 8 2 DB63 01861A TRAY STABILIZER ABS 1 SA 8 3 DB61 03341B BLADE H ABS 1 SA 8 4 DB61 01976B BLADE V PP 2 SA 8 5 DB73 00180A RUBBER CAP DRAIN GUM EPM 1 SNA 8 6 DB94 00458B ASS Y DRAIN HOSE AS...

Page 286: ...5 59 Samsung Electronics 1 6 1 2 1 9 1 1 2 2 5 2 3 7 1 3 1 4 1 6 9 4 7 2 1 2 5 1 5 4 5 3 8 1 7 1 8 5 3 3 4 3 6 3 8 1 5 3 1 3 2 3 5 3 3 5 1 15 Wall mounted type Neo Forte without EEV AVXWNH022 028 036E ND022 028 036NH 9 6 B B a LQGG ...

Page 287: ...ASS Y EVAP ASS Y 1 SNA 3 DB94 00457J ASS Y TRAY DRAIN ASS Y 1 SA 3 1 DB63 00848A TRAIN DRAIN ABS 1 SNA 3 2 DB61 01635C BRADE H HIPS 1 SA 3 3 DB61 01636A BLADE V PP 1 SA 3 4 DB63 00849A TRAY STABILIZER ABS 1 SNA 3 5 DB69 00839A CUSHION EPS TRAY RH EPS 3 SA 3 6 DB73 00180A RUBBER CAP DRAIN GUM EPM 3 SNA 3 7 DB31 00371A ASS Y MOTOR STEPPING 220 240V 50 60Hz Class E 1 SA 3 8 DB94 00458B ASS Y DRAIN HO...

Page 288: ...d Views and Parts List 5 61 Samsung Electronics 1 6 1 2 1 1 16 2 4 2 3 2 2 2 5 3 7 10 11 13 4 9 7 2 1 2 5 1 5 5 5 2 5 3 8 14 15 5 4 5 3 3 4 3 6 3 8 12 3 1 3 2 3 5 3 3 AVXWNH056 071E ND056 071NH 9 6 B B a LQGG ...

Page 289: ...USHION EPS TRAY RH EPS 1 1 SA 3 6 DB73 00180A RUBBER CAP DRAIN GUM EPM 1 1 SNA 3 7 DB31 00285A ASS Y MOTOR STEPPING 220 240V 50 60Hz Class E 1 1 SA 3 8 DB94 00458B ASS Y DRAIN HOSE ASS Y 1 1 SA 4 DB93 06038C ASS Y CONTROL IN ASS Y 1 1 SA 5 DB92 01235A ASS Y PANEL FRONT ASS Y 1 1 SA 5 1 DB64 01184C PANEL FRONT HIPS 1 1 SA 5 2 DB64 02045A ASS Y GRILLE AIR INLET ASS Y 1 1 SA 5 3 DB64 02046A DECORATON...

Page 290: ...Exploded Views and Parts List 5 63 Samsung Electronics 5 1 16 Wall mounted type Neo Forte with EEV ND022 028 036QHXE 9 6 B B a LQGG ...

Page 291: ...R BUTYL BUTYL 1 SA 2 7 DB73 00570A RUBBER BUTYL BUTYL 1 SA 3 DB94 00457J ASS Y TRAY DRAIN ASS Y 1 SA 3 1 DB63 00848A TRAIN DRAIN ABS 1 SNA 3 2 DB61 01635C BRADE H HIPS 1 SA 3 3 DB61 01636A BLADE V PP 1 SA 3 4 DB63 00849A TRAY STABILIZER ABS 1 SNA 3 5 DB69 00839A CUSHION EPS TRAY RH EPS 3 SA 3 6 DB73 00180A RUBBER CAP DRAIN GUM EPM 3 SNA 3 7 DB31 00371A ASS Y MOTOR STEPPING 220 240V 50 60Hz Class E...

Page 292: ...Exploded Views and Parts List 5 65 Samsung Electronics ND045 056 071QHXE 9 6 B B a LQGG ...

Page 293: ...B61 01975C BRADE H HIPS 1 1 SA 3 3 DB61 01976A BLADE V PP 1 1 SA 3 4 DB63 01066A TRAY STABILIZER ABS 1 1 SNA 3 5 DB69 01024A CUSHION EPS TRAY RH EPS 1 1 SA 3 6 DB73 00180A RUBBER CAP DRAIN GUM EPM 1 1 SNA 3 7 DB31 00285A ASS Y MOTOR STEPPING 220 240V 50 60Hz Class E 1 1 SA 3 8 DB94 00458B ASS Y DRAIN HOSE ASS Y 1 1 SA 4 DB93 09504C ASS Y CONTROL IN ASS Y 1 1 SA 5 DB92 01235A ASS Y PANEL FRONT ASS ...

Page 294: ...st 5 67 Samsung Electronics 5 1 17 Wall mounted type Vivace 9 17 12 11 15 10 13 14 16 5 4 8 7 3 6 1 2 13 1 13 3 13 2 2 5 2 4 2 1 2 2 2 6 2 3 1 1 1 14 1 13 1 5 1 7 1 6 1 8 1 4 1 10 1 9 1 11 1 12 1 15 1 9 1 2 1 3 1 2 9 6 B B a LQGG ...

Page 295: ... DB61 03139A SPRING ETC GRILLE STS 1 1 1 SA 1 11 DB63 01630A COVER DISPLAY ABS FR 17 1 1 1 SA 1 12 DB93 04452F ASS Y DISPLAY ASS Y 1 1 1 SA 1 13 DB61 02910A FRAME GRILLE ASS Y 1 1 1 SA 1 14 DB92 01052A WINDOW MIRROR ACRYL 1 SNA DB64 01052B WINDOW MIRROR ACRYL 1 1 SNA 1 15 DB61 03139B SPING ETC GRILLE STS 1 1 1 SA 2 DB94 01237A ASS Y TRAY DRAIN ASS Y 1 SA DB94 01245A ASS Y TRAY DRAIN ASS Y 1 1 SA 2...

Page 296: ...SPRING SENSOR STS301 2 2 2 SNA 10 DB94 00455A ASS Y BEARING RUBBER ASS Y 1 1 1 SA 11 DB94 00456A ASS Y CROSS FAN ASS Y 1 SA DB94 00456B ASS Y CROSS FAN ASS Y 1 1 SA 12 DB31 00219A MOTOR FAN ASS Y 1 SA DB31 00267A MOTOR FAN ASS Y 1 1 SA 13 DB94 01152B ASS Y BODY BACK ASS Y 1 SA DB94 01153B ASS Y BODY BACK ASS Y 1 1 SA 13 1 DB61 03028A BODY BACK HIPS 1 SA DB61 03029A BODY BACK HIPS 1 1 SA 13 2 DB93 ...

Page 297: ...MEMO Samsung Electronics 5 70 9 6 B B a LQGG ...

Page 298: ...5 71 Samsung Electronics 2 15 17 18 19 12 11 16 21 20 13 14 5 1 3 10 8 9 4 6 7 A D B C 5 2 1 RD080HHXGA RD100HHXGA RD120HHXGA 5 2 Outdoor Unit 9 6 B B a LQGG ...

Page 299: ... Parts List Samsung Electronics 5 72 25 26 22 24 23 33 28 29 30 31 27 32 52 46 53 59 58 38 37 35 34 36 39 49 57 40 42 41 45 48 54 55 56 47 43 44 51 50 60 66 67 61 6362 64 65 73 72 71 70 69 68 74 75 A C B D 9 6 B B a LQGG ...

Page 300: ...CH GRAY 1 1 1 SA 20 DB64 02368B CABINET FRONT LOW 12HP SECC P TOUCH GRAY 1 1 1 SA 21 DB61 04537A PLATE COVER INSTALLATION SECC P TOUCH GRAY 1 1 1 SA 22 DB90 05864A ASS Y CABINET CONTROL BOX ASS Y 1 1 1 SA 23 DB61 04527A CASE HUB PCB ABS 5VA 1 1 1 SA 24 DB61 04528A CASE CONTROL MAIN ABS 5VA 1 1 1 SA 25 DB63 02725A COVER FAN WIRE ABS 5VA 1 1 1 SA 26 DB64 02531A CABINET CONTROL BOX SGCC M 0 8T 1 1 1 ...

Page 301: ...3 DB95 01468C ASS Y COMP EVI ZPJ61KCE TFD 496 1 1 SA DB95 01468E ASS Y COMP EVI ZPJ83KCE TFD 496 1 SA 54 DB95 01456C ASS Y COMP EVI ZPI61KCE TFD 496 1 1 SA DB95 01456E ASS Y COMP EVI ZPI83KCE TFD 496 1 SA 55 DB97 15950A ASS Y CLOTH COMP SOUND SIDE COMP FELT 1st 1 1 1 SA 56 DB97 15951A ASS Y CLOTH COMP SOUND SIDE COMP FELT 2nd 1 1 1 SA 57 DB63 02031A COVER COMP SOUND TOP COMP COVER 1st 1 1 1 SA 58 ...

Page 302: ...Exploded Views and Parts List 5 75 Samsung Electronics 2 15 17 18 19 12 11 16 21 20 13 14 5 1 3 10 8 9 4 6 7 A D B C 5 2 2 RD080 100 120HHXGB RD080 100 120HHXGASTK RD080 100 120HHXGBXSE 9 6 B B a LQGG ...

Page 303: ...arts List Samsung Electronics 5 76 25 26 22 24 23 33 28 29 30 31 27 32 76 52 46 53 59 58 38 37 35 34 36 39 49 57 40 42 41 45 48 54 55 56 47 43 44 51 50 60 66 67 61 6362 64 65 73 72 71 70 69 68 74 75 A C B D 9 6 B B a LQGG ...

Page 304: ...3 02406A COVER WINDOW DISPLAY SECC P TOUCH GRAY 1 1 1 SA 20 DB64 02368B CABINET FRONT LOW 12HP SECC P TOUCH GRAY 1 1 1 SA 21 DB61 04537A PLATE COVER INSTALLATION SECC P TOUCH GRAY 1 1 1 SA 22 DB90 06719A ASS Y CABINET CONTROL BOX ASS Y 1 1 1 SA 23 DB61 04527A CASE HUB PCB ABS 5VA 1 1 1 SA 24 DB61 04528A CASE CONTROL MAIN ABS 5VA 1 1 1 SA 25 DB63 02725A COVER FAN WIRE ABS 5VA 1 1 1 SA 26 DB64 02794...

Page 305: ...95 01468C ASS Y COMP EVI ZPJ61KCE TFD 496 1 1 SA DB95 01468E ASS Y COMP EVI ZPJ83KCE TFD 496 1 SA 54 DB95 01456C ASS Y COMP EVI ZPI61KCE TFD 496 1 1 SA DB95 01456E ASS Y COMP EVI ZPI83KCE TFD 496 1 SA 55 DB97 15950A ASS Y CLOTH COMP SOUND SIDE COMP FELT 1st 1 1 1 SA 56 DB97 15951A ASS Y CLOTH COMP SOUND SIDE COMP FELT 2nd 1 1 1 SA 57 DB63 02031A COVER COMP SOUND TOP COMP COVER 1st 1 1 1 SA 58 DB63...

Page 306: ...Exploded Views and Parts List 5 79 Samsung Electronics 2 3 1 4 12 8 9 11 16 5 6 13 15 7 1 7 2 22 23 24 14 17 18 21 2 21 1 19 20 10 C D A B 5 2 3 RD140HHXGA 9 6 B B a LQGG ...

Page 307: ... Parts List Samsung Electronics 5 80 28 29 25 27 26 36 31 32 33 34 30 35 44 51 56 42 40 38 37 39 41 60 61 43 49 54 53 52 59 58 62 63 55 45 46 47 50 57 48 69 70 6665 67 68 64 76 75 74 73 72 71 77 78 A C B D 9 6 B B a LQGG ...

Page 308: ...19 DB90 05197A ASS Y CABI FRONT MID LF 20HP ASS Y 1 SA 20 DB90 05194B CABI FRONT LOW LF SECC P TOUCH GRAY 1 SA 21 1 DB90 05195A ASS Y CABI FRONT MID RH 20HP ASS Y 1 SA 21 2 DB63 02406A COVER WINDOW DISPLAY SECC P TOUCH GRAY 1 SA 22 DB90 05193C ASS Y CABI FRONT LOW RH ASS Y 1 SA 23 DB90 05219A ASS Y CABINET BEAM FRONT 20HP ASS Y 1 SA 24 DB61 04537A PLATE COVER INSTALLATION SECC P TOUCH GRAY 1 SA 25...

Page 309: ...01456E ASS Y COMP EVI ZPI83KCE TFD 496 1 SA 58 DB97 15950A ASS Y CLOTH COMP SOUND SIDE COMP FELT 1st 1 SA 59 DB97 15951A ASS Y CLOTH COMP SOUND SIDE COMP FELT 2nd 1 SA 60 DB63 02031A COVER COMP SOUND TOP COMP COVER 1st 1 SA 61 DB63 02032A COVER COMP SOUND TOP COMP COVER 2nd 1 SA 62 DB95 00766P ASS Y COMP HEATER ASS Y 1 SA 63 DB95 00766Q ASS Y COMP HEATER ASS Y 1 SA 64 DB95 04693A ASS Y THEMISTOR 2...

Page 310: ...Exploded Views and Parts List 5 83 Samsung Electronics 2 3 1 4 12 8 9 11 16 5 6 13 15 7 1 7 2 22 23 24 14 17 18 21 2 21 1 19 20 10 C D A B 5 2 4 RD140HHXGB RD140HHXGASTK RD140HHXGBXSE 9 6 B B a LQGG ...

Page 311: ...arts List Samsung Electronics 5 84 28 29 25 27 26 36 31 32 33 34 30 35 79 44 51 56 42 40 38 37 39 41 60 61 43 49 54 53 52 59 58 62 63 55 45 46 47 50 57 48 69 70 6665 67 68 64 76 75 74 73 72 71 77 78 A C B D 9 6 B B a LQGG ...

Page 312: ...SS Y FRONT BEAM POWER BOX ASS Y 1 SA 19 DB90 05197A ASS Y CABI FRONT MID LF 20HP ASS Y 1 SA 20 DB90 05194B CABI FRONT LOW LF SECC P TOUCH GRAY 1 SA 21 1 DB90 05195A ASS Y CABI FRONT MID RH 20HP ASS Y 1 SA 21 2 DB63 02406A COVER WINDOW DISPLAY SECC P TOUCH GRAY 1 SA 22 DB90 05193C ASS Y CABI FRONT LOW RH ASS Y 1 SA 23 DB90 05219A ASS Y CABINET BEAM FRONT 20HP ASS Y 1 SA 24 DB61 04537A PLATE COVER I...

Page 313: ... 1 SA 57 DB95 01456E ASS Y COMP EVI ZPI83KCE TFD 496 1 SA 58 DB97 15950A ASS Y CLOTH COMP SOUND SIDE COMP FELT 1st 1 SA 59 DB97 15951A ASS Y CLOTH COMP SOUND SIDE COMP FELT 2nd 1 SA 60 DB63 02031A COVER COMP SOUND TOP COMP COVER 1st 1 SA 61 DB63 02032A COVER COMP SOUND TOP COMP COVER 2nd 1 SA 62 DB95 00766P ASS Y COMP HEATER ASS Y 1 SA 63 DB95 00766Q ASS Y COMP HEATER ASS Y 1 SA 64 DB95 04693A ASS...

Page 314: ...Exploded Views and Parts List 5 87 Samsung Electronics 5 2 5 RD160HHXGA RD180HHXGA RD200HHXGA 2 3 1 4 12 8 9 11 16 5 6 13 15 7 1 7 2 22 23 24 14 17 18 21 2 21 1 19 20 10 C D A B 9 6 B B a LQGG ...

Page 315: ... Samsung Electronics 5 88 28 29 25 27 26 37 32 31 33 34 35 30 36 39 38 40 44 61 62 62 51 45 47 48 49 55 56 46 43 41 42 50 53 58 58 52 63 64 65 59 60 60 54 57 72 73 73 68 70 67 69 68 71 80 79 78 77 76 75 84 85 A C D B 9 6 B B a LQGG ...

Page 316: ...LF 20HP ASS Y 1 1 1 SA 20 DB90 05194B CABI FRONT LOW LF SECC P TOUCH GRAY 1 1 1 SA 21 1 DB90 05195A ASS Y CABI FRONT MID RH 20HP ASS Y 1 1 1 SA 21 2 DB63 02406A COVER WINDOW DISPLAY SECC P TOUCH GRAY 1 1 1 SA 22 DB90 05193C ASS Y CABI FRONT LOW RH ASS Y 1 1 1 SA 23 DB90 05219A ASS Y CABINET BEAM FRONT 20HP ASS Y 1 1 1 SA 24 DB61 04537A PLATE COVER INSTALLATION SECC P TOUCH GRAY 1 1 1 SA 25 DB90 05...

Page 317: ...VI ZPJ83KCE TFD 496 1 1 SA 58 DB95 01456D ASS Y COMP EVI ZPI72KCE TFD 496 2 SA DB95 01456E ASS Y COMP EVI ZPI83KCE TFD 496 2 2 SA 59 DB97 15950A ASS Y CLOTH COMP SOUND SIDE COMP FELT 1st 1 1 1 SA 60 DB97 15951A ASS Y CLOTH COMP SOUND SIDE COMP FELT 2nd 3rd 2 2 2 SA 61 DB63 02031A COVER COMP SOUND TOP COMP COVER 1st 1 1 1 SA 62 DB63 02032A COVER COMP SOUND TOP COMP COVER 2nd 3rd 2 2 2 SA 63 DB95 00...

Page 318: ...iews and Parts List 5 91 Samsung Electronics 5 2 6 RD160 180 200HHXGB RD160 180 200HHXGASTK RD160 180 200HHXGBXSE 2 3 1 4 12 8 9 11 16 5 6 13 15 7 1 7 2 22 23 24 14 17 18 21 2 21 1 19 20 10 C D A B 9 6 B B a LQGG ...

Page 319: ...amsung Electronics 5 92 28 29 25 27 26 37 32 31 33 34 35 30 36 83 39 38 40 44 61 62 62 51 45 47 48 49 55 56 46 43 41 42 50 53 58 58 52 63 64 65 59 60 60 54 57 72 73 74 68 70 67 69 66 71 80 79 78 77 76 75 81 82 A C D B 9 6 B B a LQGG ...

Page 320: ...ASS Y CABI FRONT MID LF 20HP ASS Y 1 1 1 SA 20 DB90 05194B CABI FRONT LOW LF SECC P TOUCH GRAY 1 1 1 SA 21 1 DB90 05195A ASS Y CABI FRONT MID RH 20HP ASS Y 1 1 1 SA 21 2 DB63 02406A COVER WINDOW DISPLAY SECC P TOUCH GRAY 1 1 1 SA 22 DB90 05193C ASS Y CABI FRONT LOW RH ASS Y 1 1 1 SA 23 DB90 05219A ASS Y CABINET BEAM FRONT 20HP ASS Y 1 1 1 SA 24 DB61 04537A PLATE COVER INSTALLATION SECC P TOUCH GRA...

Page 321: ...J83KCE TFD 496 1 1 SA 58 DB95 01456D ASS Y COMP EVI ZPI72KCE TFD 496 2 SA DB95 01456E ASS Y COMP EVI ZPI83KCE TFD 496 2 2 SA 59 DB97 15950A ASS Y CLOTH COMP SOUND SIDE COMP FELT 1st 1 1 1 SA 60 DB97 15951A ASS Y CLOTH COMP SOUND SIDE COMP FELT 2nd 3rd 2 2 2 SA 61 DB63 02031A COVER COMP SOUND TOP COMP COVER 1st 1 1 1 SA 62 DB63 02032A COVER COMP SOUND TOP COMP COVER 2nd 3rd 2 2 2 SA 63 DB95 00766P ...

Page 322: ...Exploded Views and Parts List 5 95 Samsung Electronics 2 15 17 18 19 12 11 16 21 20 13 14 5 1 3 10 8 9 4 6 7 A D B C 5 2 7 RD080 100 120HRXGA 9 6 B B a LQGG ...

Page 323: ... Parts List Samsung Electronics 5 96 25 26 22 24 23 33 28 29 30 31 27 32 40 41 42 46 52 58 44 35 36 34 38 37 39 45 51 48 47 53 54 43 59 55 56 57 60 50 49 66 67 61 6362 64 65 73 72 71 70 69 68 74 75 A C B D 9 6 B B a LQGG ...

Page 324: ...UCH GRAY 1 1 1 SA 20 DB64 02368B CABINET FRONT LOW 12HP SECC P TOUCH GRAY 1 1 1 SA 21 DB61 04537A PLATE COVER INSTALLATION SECC P TOUCH GRAY 1 1 1 SA 22 DB90 05864A ASS Y CABINET CONTROL BOX ASS Y 1 1 1 SA 23 DB61 04527A CASE HUB PCB ABS 5VA 1 1 1 SA 24 DB61 04528A CASE CONTROL MAIN ABS 5VA 1 1 1 SA 25 DB63 02725A COVER FAN WIRE ABS 5VA 1 1 1 SA 26 DB64 02531A CABINET CONTROL BOX SGCC M 0 8T 1 1 1...

Page 325: ...1 SA DB95 01468E ASS Y COMP EVI ZPJ83KCE TFD 496 1 SA 54 DB95 01456C ASS Y COMP EVI ZPI61KCE TFD 496 1 1 SA DB95 01456E ASS Y COMP EVI ZPI83KCE TFD 496 1 SA 55 DB97 15950A ASS Y CLOTH COMP SOUND SIDE COMP FELT 1st 1 1 1 SA 56 DB97 15951A ASS Y CLOTH COMP SOUND SIDE COMP FELT 2nd 1 1 1 SA 57 DB63 02031A COVER COMP SOUND TOP COMP COVER 1st 1 1 1 SA 58 DB63 02032A COVER COMP SOUND TOP COMP COVER 2nd ...

Page 326: ...Exploded Views and Parts List 5 99 Samsung Electronics 2 15 17 18 19 12 11 16 21 20 13 14 5 1 3 10 8 9 4 6 7 A D B C 5 2 8 RD080 100 120HRXGB RD080 100 120HRXGASTK 9 6 B B a LQGG ...

Page 327: ...arts List Samsung Electronics 5 100 25 26 22 24 23 33 28 29 30 31 27 32 76 40 41 42 46 52 58 44 35 36 34 38 37 39 45 51 48 47 53 54 43 59 55 56 57 60 50 49 66 67 61 6362 64 65 73 72 71 70 69 68 74 75 A C B D 9 6 B B a LQGG ...

Page 328: ...AY SECC P TOUCH GRAY 1 1 1 SA 20 DB64 02368B CABINET FRONT LOW 12HP SECC P TOUCH GRAY 1 1 1 SA 21 DB61 04537A PLATE COVER INSTALLATION SECC P TOUCH GRAY 1 1 1 SA 22 DB90 06719A ASS Y CABINET CONTROL BOX ASS Y 1 1 1 SA 23 DB61 04527A CASE HUB PCB ABS 5VA 1 1 1 SA 24 DB61 04528A CASE CONTROL MAIN ABS 5VA 1 1 1 SA 25 DB63 02725A COVER FAN WIRE ABS 5VA 1 1 1 SA 26 DB64 02794A CABINET CONTROL BOX SGCC ...

Page 329: ...PJ83KCE TFD 496 1 SA 54 DB95 01456C ASS Y COMP EVI ZPI61KCE TFD 496 1 1 SA DB95 01456E ASS Y COMP EVI ZPI83KCE TFD 496 1 SA 55 DB97 15950A ASS Y CLOTH COMP SOUND SIDE COMP FELT 1st 1 1 1 SA 56 DB97 15951A ASS Y CLOTH COMP SOUND SIDE COMP FELT 2nd 1 1 1 SA 57 DB63 02031A COVER COMP SOUND TOP COMP COVER 1st 1 1 1 SA 58 DB63 02032A COVER COMP SOUND TOP COMP COVER 2nd 1 1 1 SA 59 DB95 00766P ASS Y COM...

Page 330: ...Exploded Views and Parts List 5 103 Samsung Electronics 2 3 1 4 12 8 9 11 16 5 6 13 15 7 1 7 2 22 23 24 14 17 18 21 2 21 1 19 20 10 C D A B 5 2 9 RD140HRXGA 9 6 B B a LQGG ...

Page 331: ...d Parts List Samsung Electronics 5 104 28 29 25 27 26 36 31 32 33 34 30 35 53 51 52 48 60 59 44 54 43 47 42 41 38 37 39 40 45 46 49 50 61 57 58 62 55 56 69 70 6665 67 68 64 76 75 74 73 72 71 77 78 A C B D 9 6 B B a LQGG ...

Page 332: ...A 19 DB90 05197A ASS Y CABI FRONT MID LF 20HP ASS Y 1 SA 20 DB90 05194B CABI FRONT LOW LF SECC P TOUCH GRAY 1 SA 21 1 DB90 05195A ASS Y CABI FRONT MID RH 20HP ASS Y 1 SA 21 2 DB63 02406A COVER WINDOW DISPLAY SECC P TOUCH GRAY 1 SA 22 DB90 05193C ASS Y CABI FRONT LOW RH ASS Y 1 SA 23 DB90 05219A ASS Y CABINET BEAM FRONT 20HP ASS Y 1 SA 24 DB61 04537A PLATE COVER INSTALLATION SECC P TOUCH GRAY 1 SA ...

Page 333: ...ZPI83KCE TFD 496 1 SA 57 DB97 15950A ASS Y CLOTH COMP SOUND SIDE COMP FELT 1st 1 SA 58 DB97 15951A ASS Y CLOTH COMP SOUND SIDE COMP FELT 2nd 1 SA 59 DB63 02031A COVER COMP SOUND TOP COMP COVER 1st 1 SA 60 DB63 02032A COVER COMP SOUND TOP COMP COVER 2nd 1 SA 61 DB95 00766P ASS Y COMP HEATER ASS Y 1 SA 62 DB95 00766Q ASS Y COMP HEATER ASS Y 1 SA 64 DB95 04694A ASS Y THEMISTOR 2COMP TOTAL ASS Y 1 SA ...

Page 334: ...Exploded Views and Parts List 5 107 Samsung Electronics 2 3 1 4 12 8 9 11 16 5 6 13 15 7 1 7 2 22 23 24 14 17 18 21 2 21 1 19 20 10 C D A B 5 2 10 RD140HRXGB RD140HRXGASTK 9 6 B B a LQGG ...

Page 335: ...Parts List Samsung Electronics 5 108 28 29 25 27 26 36 31 32 33 34 30 35 79 53 51 52 48 60 59 44 54 43 47 42 41 38 37 39 40 45 46 49 50 61 57 58 62 55 56 69 70 6665 67 68 64 76 75 74 73 72 71 77 78 A C B D 9 6 B B a LQGG ...

Page 336: ...S Y FRONT BEAM POWER BOX ASS Y 1 SA 19 DB90 05197A ASS Y CABI FRONT MID LF 20HP ASS Y 1 SA 20 DB90 05194B CABI FRONT LOW LF SECC P TOUCH GRAY 1 SA 21 1 DB90 05195A ASS Y CABI FRONT MID RH 20HP ASS Y 1 SA 21 2 DB63 02406A COVER WINDOW DISPLAY SECC P TOUCH GRAY 1 SA 22 DB90 05193C ASS Y CABI FRONT LOW RH ASS Y 1 SA 23 DB90 05219A ASS Y CABINET BEAM FRONT 20HP ASS Y 1 SA 24 DB61 04537A PLATE COVER IN...

Page 337: ...Y COMP EVI ZPI83KCE TFD 496 1 SA 57 DB97 15950A ASS Y CLOTH COMP SOUND SIDE COMP FELT 1st 1 SA 58 DB97 15951A ASS Y CLOTH COMP SOUND SIDE COMP FELT 2nd 1 SA 59 DB63 02031A COVER COMP SOUND TOP COMP COVER 1st 1 SA 60 DB63 02032A COVER COMP SOUND TOP COMP COVER 2nd 1 SA 61 DB95 00766P ASS Y COMP HEATER ASS Y 1 SA 62 DB95 00766Q ASS Y COMP HEATER ASS Y 1 SA 64 DB95 04694A ASS Y THEMISTOR 2COMP TOTAL ...

Page 338: ...Exploded Views and Parts List 5 111 Samsung Electronics 5 2 11 RD160 180 200HRXGA 2 3 1 4 12 8 9 11 16 5 6 13 15 7 1 7 2 22 23 24 14 17 18 21 2 21 1 19 20 10 C D A B 9 6 B B a LQGG ...

Page 339: ... List Samsung Electronics 5 112 28 29 25 27 26 37 32 31 33 34 35 30 36 44 39 38 40 41 49 43 56 55 51 46 52 53 48 58 47 50 54 63 62 61 45 57 59 64 65 60 72 73 74 68 70 67 69 66 71 80 79 78 77 76 75 81 82 A C D B 9 6 B B a LQGG ...

Page 340: ...LF 20HP ASS Y 1 1 1 SA 20 DB90 05194B CABI FRONT LOW LF SECC P TOUCH GRAY 1 1 1 SA 21 1 DB90 05195A ASS Y CABI FRONT MID RH 20HP ASS Y 1 1 1 SA 21 2 DB63 02406A COVER WINDOW DISPLAY SECC P TOUCH GRAY 1 1 1 SA 22 DB90 05193C ASS Y CABI FRONT LOW RH ASS Y 1 1 1 SA 23 DB90 05219A ASS Y CABINET BEAM FRONT 20HP ASS Y 1 1 1 SA 24 DB61 04537A PLATE COVER INSTALLATION SECC P TOUCH GRAY 1 1 1 SA 25 DB90 05...

Page 341: ...VI ZPJ83KCE TFD 496 1 1 SA 58 DB95 01456D ASS Y COMP EVI ZPI72KCE TFD 496 2 SA DB95 01456E ASS Y COMP EVI ZPI83KCE TFD 496 2 2 SA 59 DB97 15950A ASS Y CLOTH COMP SOUND SIDE COMP FELT 1st 1 1 1 SA 60 DB97 15951A ASS Y CLOTH COMP SOUND SIDE COMP FELT 2nd 3rd 2 2 2 SA 61 DB63 02031A COVER COMP SOUND TOP COMP COVER 1st 1 1 1 SA 62 DB63 02032A COVER COMP SOUND TOP COMP COVER 2nd 3rd 2 2 2 SA 63 DB95 00...

Page 342: ...Exploded Views and Parts List 5 115 Samsung Electronics 5 2 12 RD160 180 200HRXGB RD160 180 200HRXGASTK 2 3 1 4 12 8 9 11 16 5 6 13 15 7 1 7 2 22 23 24 14 17 18 21 2 21 1 19 20 10 C D A B 9 6 B B a LQGG ...

Page 343: ...List Samsung Electronics 5 116 44 39 38 40 41 49 43 56 55 51 46 52 53 48 58 47 50 54 63 62 61 45 57 59 64 65 60 28 29 25 27 26 37 32 31 33 34 35 30 36 83 72 73 74 68 70 67 69 66 71 80 79 78 77 76 75 81 82 A C D B 9 6 B B a LQGG ...

Page 344: ...ASS Y CABI FRONT MID LF 20HP ASS Y 1 1 1 SA 20 DB90 05194B CABI FRONT LOW LF SECC P TOUCH GRAY 1 1 1 SA 21 1 DB90 05195A ASS Y CABI FRONT MID RH 20HP ASS Y 1 1 1 SA 21 2 DB63 02406A COVER WINDOW DISPLAY SECC P TOUCH GRAY 1 1 1 SA 22 DB90 05193C ASS Y CABI FRONT LOW RH ASS Y 1 1 1 SA 23 DB90 05219A ASS Y CABINET BEAM FRONT 20HP ASS Y 1 1 1 SA 24 DB61 04537A PLATE COVER INSTALLATION SECC P TOUCH GRA...

Page 345: ...PJ83KCE TFD 496 1 1 SA 58 DB95 01456D ASS Y COMP EVI ZPI72KCE TFD 496 2 SA DB95 01456E ASS Y COMP EVI ZPI83KCE TFD 496 2 2 SA 59 DB97 15950A ASS Y CLOTH COMP SOUND SIDE COMP FELT 1st 1 1 1 SA 60 DB97 15951A ASS Y CLOTH COMP SOUND SIDE COMP FELT 2nd 3rd 2 2 2 SA 61 DB63 02031A COVER COMP SOUND TOP COMP COVER 1st 1 1 1 SA 62 DB63 02032A COVER COMP SOUND TOP COMP COVER 2nd 3rd 2 2 2 SA 63 DB95 00766P...

Page 346: ...Exploded Views and Parts List 5 119 Samsung Electronics 5 2 13 MCU 4EAE3 6EAE3 14 13 10 2 3 4 5 6 7 8 9 11 12 1 14 3 6 1 6 2 14 1 14 2 14 5 14 4 10 2 10 1 13 1 13 2 13 4 13 5 13 3 9 6 B B a LQGG ...

Page 347: ...CASE CABI LF ASS Y 1 1 SNA 10 1 DB61 03096A CASE CABI LF SGCC M T 1 0 1 1 SNA 10 2 DB61 00712A HOLDER SIDE CABI SGCC M T2 3 2 2 SNA 11 DB61 03095A CASE BASE SGCC M T 1 0 1 SNA DB61 03095B CASE BASE SGCC M T 1 0 1 SNA 12 DB67 00620A DRAIN BOX HIPS T2 0 BLK 1 1 SNA 13 DB96 08861A ASS Y LIQUID LINE ASS Y 1 SNA DB96 08838A ASS Y LIQUID LINE ASS Y 1 SNA 13 1 DB62 04065A VALVE EXPANSION BODY DPF Q 1 65C...

Page 348: ...C12V 2 5 Louver control 1 3 DC12V 2 Error CHK Out 4 Comp CHK Out 1 Comm Signal F1 2 Comm Signal F2 1 Comm Signal F3 2 Comm Signal F4 1 ROOMTemp Sensor 2 GND 3 EVA INTemp sensor 4 GND 1 GND 2 Float S W 1 On off Contact point input 2 GND 1 6 DC12V 2 5 Motor Control 7 10 Not used CN74 Ventilator CN74 Drain Pump CN73 Fan Motor CN71 AC Power CN44 RPM Feedback CN32 Remocon DC12V CN10 Micom Download CN91 ...

Page 349: ...GND 9 VCC 1 4 EEV Output Signal 5 DC12V 1 DC12V 2 5 Louver Output Signal 1 F1 Red 2 F2 Blue 1 F3 Red 2 F4 Blue 1 V1 White 2 V2 Black 1 Room Sensor 3 EVA IN Sensor 5 EVA Out Sensor 2 4 6 GND CN100 POWER INPUT CN74 DRAIN CN73 BLDC FAN CN86 DISPLAY CN85 EEV CN81 V LOUVER CN31 COMM1 CN33 COMM2 CN32 12V Power CN41 Indoor Unit Sensor Slim 1 way cassette type cont MAIN PCB ND0561 0711 HXE Series 1 2 4 6 ...

Page 350: ...Electronics Panel AVXCSH022 028 036E ND022 028 0361H DC connecting connector 1 5 Control Display LED 6 Not used 7 Receive signals from wireless remote controller 8 GND 9 VCC DC5V CN01 Connect the Main PBA of the Indoor Unit 1 9 6 B B a LQGG ...

Page 351: ...t Samsung Electronics 6 4 Panel ND0561 0711HXE Series DC connecting connector 1 5 Display LED Control 6 Not in use 7 Send Wireless Remote Controller Signal 8 GND 9 VCC DC5V Cn01 Indoor Unit Main Pba Connection 1 9 6 B B a LQGG ...

Page 352: ...PCB Diagram and Parts List 6 5 Samsung Electronics 6 1 2 2 way cassette type A B 14 15 17 16 18 13 7 6 5 4 3 2 1 22 21 20 19 12 11 10 9 8 23 24 25 9 6 B B a LQGG ...

Page 353: ...1 N Phase 3 FAN CAP output 1 input operating capacitor motor 2 4 no used 3 Motor control signal 5 N phase voltage 1 input operating capacitor motor 2 4 no used 3 Motor control signal 5 N phase voltage 1 L phase 2 N phase 1 3 DC12V 2 ERROR CHK OUT 4 COMP CHK OUT 1 On off Contact point input 2 GND CN75 Ventilator CN31 Indoor Outdoor Unit Communication CN33 Wired Remote Controller Communication CN52 R...

Page 354: ...nication F1 2 Communication F2 1 DC12V 2 GND 1 5 Display Control Signal 7 Remote Sihnal Receive 8 GND 9 VCC DC5V 1 DV310V 2 N C 3 GND 4 DC15V 5 Motor Control Signal 6 Motor Feedback Signal 1 L Phase 2 N Phase 1 N Phase 2 Drain Pump Control 1 N Phase 2 Ventilator Control CN83 EXTANAL CONTROL CN51 FLOAT S W CN41 ROOM EVA IN CN42 EVA OUT TEMP SENSOR CN62 EEV CN76 EXTERNAL OPTION CN60 LOUVER CN81 EXTE...

Page 355: ...GND 1 EVA OutThermistor 2 GND 1 GND 2 Heater Discharge Output 1 5V input 2 GND 3 Hall IC output 1 Comm Signal F3 2 Comm Signal F4 1 Comm Signal F1 2 Comm Signal F2 1 DC12V 2 GND 1 5 LED Control 6 AUTO_S W 7 REMOCON_SIGNAL 8 GND 9 VCC 1 DC12V 2 FAN SSR OUT CN62 Electrically Operated Valve Control CN76 SUB PCB Connection CN60 Louver CN81 External Control Out CN75 Ventilator CN74 Drain pump CN73 Fan ...

Page 356: ...PCB Diagram and Parts List 6 9 Samsung Electronics 22 2 21 1 2 3 4 5 6 7 8 9 10 11 13 12 20 19 18 17 16 15 14 6 1 5 Duct type Slim MAIN PCB 9 6 B B a LQGG ...

Page 357: ...Remocon receiving signal 10 GND 11 DC5V 1 Comm Signal F1 2 Comm Signal F2 1 Comm Signal F3 2 Comm Signal F4 1 3 Trans OUtput connect 1 AC Power L 2 AC Power N 1 AC Power L 2 AC Power N None 1 DC12V 2 Fan Control Signal None 1 N phase 2 heated water coil signal 1 N phase 2 Drain signal 1 N phase 2 Ventilator signal CN43 CCH Temp sensor CN81 External CHECK CN32 Wire Remocon Power CN83 External Contr...

Page 358: ...1 Duct type Slim SUB PCB 1 AC Power L 2 AC Power N 1 ROOMTemp Sensor 2 GND 3 EVA INTemp sensor 4 GND 1 DC310V 2 not used 3 GND 4 DC15V 5 Motor Control signal 6 Motor Feedback Signal CN71 AC Input CN35 MAIN PCB Connection CN72 FAN Motor output 9 6 B B a LQGG ...

Page 359: ...MEMO Samsung Electronics 6 12 9 6 B B a LQGG ...

Page 360: ...PCB Diagram and Parts List 6 13 Samsung Electronics 22 21 11 10 14 1 2 3 4 5 6 7 8 9 20 12 13 19 18 17 16 15 6 1 6 Duct type MSP MAIN PCB 9 6 B B a LQGG ...

Page 361: ...ANS outpu connnection 1 L phase 3 N phase 1 AC power L 3 AC power N 1 N phase output 3 SSR Control signal L phase 5 N phase output 1 SSR Output 3 SSR Iuput 1 12V 3 Control Signal 1 N phase 2 heated water coil signal 1 N phase 2 Drain pump signal 1 N phase 2 Ventilator signal CN51 Float Switch CN41 Temp Sensor CN42 Temp Sensor CN43 Heater Discharge CN32 Wired Remocon Power CN83 External Control CN6...

Page 362: ...PCB Diagram and Parts List 6 15 Samsung Electronics 20 19 18 10 12 1 2 3 4 5 6 7 8 11 17 16 15 14 13 6 1 7 Duct type HSP MAIN PCB 9 9 6 B B a LQGG ...

Page 363: ...K 1 3 TRANS outpu connnection 1 L phase 3 N phase 1 AC power L 3 AC power N 1 N phase output 3 SSR Control signal L phase 5 N phase output 1 SSR Output 3 SSR Iuput 1 12V 3 Control Signal 1 N phase 2 heated water coil signal 1 N phase 2 Drain pump signal 1 N phase 2 Ventilator signal CN51 Float Switch CN41 Temp Sensor CN42 Temp Sensor CN32 Wired Remocon Power CN83 External Control CN62 EEV CN91 Dis...

Page 364: ... 3 12Vdc 2 Error Check Out 4 Comp Check Out 1 2 Room 3 4 EVA1 IN 1 2 EVA1 OUT 3 4 EVA2 IN 5 6 EVA2 OUT 1 12Vdc 2 Ground CN62 EEV1 CN61 EEV2 CN81 Operation Check Signal CN10 Download CN73 Fan Motor1 CN72 Fan Motor2 CN91 Display CN83 External Control Signal CN41 Temperature Sensor CN42 Temperature Sensor CN31 Communication1 CN33 Wired Remote Controller Communication CN32 2PIn WHT 12Vdc 6 17 Samsung ...

Page 365: ...MEMO Samsung Electronics 6 18 9 6 B B a LQGG ...

Page 366: ...PCB Diagram and Parts List 6 19 Samsung Electronics 6 1 9 Duct type BIG MAIN PCB 19 18 15 14 13 1 2 4 5 6 7 8 9 3 17 16 12 11 10 9 6 B B a LQGG ...

Page 367: ...3 2 Comm Signal F4 1 3 Trans Output 1 AC Power L 2 AC Power N 1 AC Power L 2 AC Power N 1 DC12V 2 Error Check Signal 3 DC12V 4 Comp Check Signal 1 DC12V 3 Fan Control Signal 1 N phase 2 Drain Pump Signal 1 N Phase 2 Ventilator Signal CN32 Wired Remocon Power CN83 External Control CN62 EEV CN91 Display CN51 Floating Switch CN41 Room Eva In Temp Sensor CN42 Eva Out Temp Sensor CN43 Discharge Temp Se...

Page 368: ...PCB Diagram and Parts List 6 21 Samsung Electronics Duct type BIG cont EMI PCB 3 4 5 2 1 Power Output N Power Input L Power Input N Earth Power Output L 9 6 B B a LQGG ...

Page 369: ...2 1 1 DC12V 2 GND 3 DC5V 4 FAN Signal 5 FAN RPM 8 Inrush 1 AC Power L 2 AC Power N 1 AC Power L 2 AC Power N 1 3 5 U V W Feedback 2 DC5V 4 GND 6 MotorTemperature 7 GND 1 U 2 V 3 W CN13 Motor Control CN11 Main PCB Connection CN14 AC Power 10 AC Power CN12 Motor DC Connector 9 6 B B a LQGG ...

Page 370: ...OMTemp Sensor 2 GND 3 EVA INTemp sensor 4 GND 1 On off Contact point input 2 GND 1 GND 2 Float S W 1 DC12V 2 5 LOUVER control 1 DC12V 2 3 GND 1 N 2 L 1 EEV 2 DC12V CN32 Remocon DC12V CN31 Indoor Outdoor Unit Communication CN33 Wired Remocon Communication CN91 Display CN71 AC Power CN74 Drain Pump CN75 Ventilator CN73 Fan Motor CN81 External Control OUT CN42 Temp Sensor CN41 Temp sensor CN83 Externa...

Page 371: ...e REMOCON signal 9 GND 10 VCC DC5V 1 DC12V 2 5 Control Signal 1 Comm Signal F1 2 Comm Signal F2 1 DC12V 2 5 Control Signal 1 Comm Signal F1 2 Comm Signal F2 For developer only Not available in Actual Site 7 Pin Down Loader For Developer only Not available in Actual Site 10 Pin Down Loader CN70 GND CN100 AC Power Input CN75 Ventilator Output CN73 Fan Motor Output BLDC CN86 Sub PBA CN42 EVA Out CN41...

Page 372: ...tronics Console cont DISPLAY DC Connector 1 2 3 4 5 Display LED Control 6 TOUCH S W Reset DC5V 7 TOUCH S W out DC5V 8 Receive REMOCON Signal 9 GND 10 VCC DC5V CN01 Panel Display 1 DAMPER 1 DC Connector 1 DC5V 2 GND CN01 Damper S W 9 6 B B a LQGG ...

Page 373: ...MEMO Samsung Electronics 6 26 9 6 B B a LQGG ...

Page 374: ...PCB Diagram and Parts List 6 27 Samsung Electronics 6 1 12 Wall mounted type Montblanc MAIN 1 2 4 16 13 14 15 12 3 5 6 7 8 9 10 9 6 B B a LQGG ...

Page 375: ... 11 14 GND 15 External Control Signal 16 Comp Check Signal 17 19 12V 18 Error Check Signal 1 GND 2 5V 3 Recomon Receiver Signal 4 Operating Switch 1 4 EEV Control Signal 5 12V 1 4 Display Control 5 5V 6 GND 7 Recomon Receiver Signal 8 12V 9 MPI LED 1 12V 2 5 Auto Grille Control CN73 Fan Motor CN71 AC Power CN82 MPI CN60 Up Down Louver CN33 Wired Remocon comm CN32 Wired Remocon Power CN61 Option Se...

Page 376: ...B Diagram and Parts List 6 29 Samsung Electronics Wall mounted type Montblanc cont SUB SWITCH No CN COLOR FUNCTION CN61 Black Main Sub PCB Connecor CN83 White External Contact Control 17 18 9 6 B B a LQGG ...

Page 377: ...MEMO Samsung Electronics 6 30 9 6 B B a LQGG ...

Page 378: ...PCB Diagram and Parts List 6 31 Samsung Electronics 6 1 13 Wall mounted type Neo Forte without EEV MAIN 1 2 4 16 13 14 15 12 3 5 6 7 8 9 10 11 9 6 B B a LQGG ...

Page 379: ...4 GND 15 External Control Signal 16 Comp Check Signal 17 19 12V 18 Error Check Signal 1 Display Control 3 Operating switch 4 5V 5 Remocon Receiver signal 6 GND 1 4 EEV control Signal 5 12V 1 4 Electrically Operated Valve Signal 5 12V 1 12V 2 5 Auto Grille Control CN73 Fan Motor CN71 AC Power CN82 MPI Not Used CN60 Up Down Louver CN33 Communication 2 REMOCON CN32 Wired Remocon Power CN61 Option Set...

Page 380: ...ram and Parts List 6 33 Samsung Electronics Wall mounted type Neo Forte without EEV cont SUB SWITCH No CN COLOR FUNCTION CN61 Black Main Sub PCB Connecor CN83 White External Contact Control 15 16 9 6 B B a LQGG ...

Page 381: ...MEMO Samsung Electronics 6 34 9 6 B B a LQGG ...

Page 382: ...PCB Diagram and Parts List 6 35 Samsung Electronics 6 1 14 Wall mounted type Neo Forte with EEV MAIN 7 1 2 3 4 5 6 8 9 10 11 13 12 9 6 B B a LQGG ...

Page 383: ...l 17 19 12V 18 Error Check Signal 1 DC12V 2 5 Louver Control Signal 1 L Phase 3 N Phase 1 2 14 15 DISPLAY Signal 3 Operation S W 4 DC5V 5 Wireless Remocon Signal 6 GND 1 Start Capacitor 3 Motor Control 5 N Phase 1 4 EEV Control 5 6 DC12V CN42 Temp Sensor CN41 Temp Sensor CN44 RPM Feedback CN31 Outdoor Comm CN71 AC Power CN33 Wired Remocon Comm CN32 Wired Remocon DC Power CN61 Connect to SUB CN62 E...

Page 384: ...ung Electronics Wall mounted type Neo Forte with EEV cont SUB SWITCH 15 14 16 1 On Off Contact Switch Input 2 GND 1 3 DC12V 2 Error Check Out 4 Comp Check Out CN83 External Control CN61 Connect to Main CN42 External Control 9 6 B B a LQGG ...

Page 385: ...MEMO Samsung Electronics 6 38 9 6 B B a LQGG ...

Page 386: ...PCB Diagram and Parts List 6 39 Samsung Electronics 6 1 15 Wall mounted type Vivace 15 14 13 1 2 3 12 10 4 5 6 7 8 9 11 9 6 B B a LQGG ...

Page 387: ...20 Option Switch Address Signal 11 14 GND 15 External Control Signal 16 Comp Check Signal 17 19 12V 18 Error Check Signal 1 Not Used 2 12 Display Control 13 Operating Switch 14 5V 15 Remocon Receiver Signal 16 GND 1 4 EEV Control Signal 5 12V 1 12V 2 5 Auto Grille Control CN73 Fan Motor CN71 AC Power CN82 MPI CN60 Up Down Louver CN33 Wired Remocon Comm CN32 Wired Remocon Power CN61 Option Setup Su...

Page 388: ...CB Diagram and Parts List 6 41 Samsung Electronics Wall mounted type Vivace cont SUB SWITCH No CN COLOR FUNCTION CN61 Black Main Sub PCB Connecor CN83 White External Contact Control 15 16 9 6 B B a LQGG ...

Page 389: ...MEMO Samsung Electronics 6 42 9 6 B B a LQGG ...

Page 390: ...6 43 Samsung Electronics 2 1 11 10 4 5 9 6 7 8 6 2 Outdoor Unit 6 2 1 ASS Y PCB MAIN RD HHXGA RD HRXGA Series 9 6 B B a LQGG ...

Page 391: ...essure sensor 6 Low pressure sensor 7 ZERO_CROSSING 8 PWM_VALVE 9 VCC 10 GND 1 2 Communication 1 VCC 2 3 4 CT 1 2 3 5 12V 6 7 8 9 10 RELAY 1 2 3 4 5 11 12 13 3phase detect 14 GND 1 12V 2 GND CN92 MAIN TO BLDC CN31 Communication CN13 Transmitter DC Power 12V CN42 MAIN TO HUB CN33 Comm Inspection CN41 MAINTO CT CN12 DC power for backup tool OPT1 MODE SELECTOR CN85 Check condition CN22 Download using...

Page 392: ...PCB Diagram and Parts List 6 45 Samsung Electronics 2 1 11 3 10 4 5 6 7 8 9 12 6 2 2 ASS Y PCB MAIN RD HHXGB RD HRXGB Series 9 6 B B a LQGG ...

Page 393: ...ssure sensor 6 Low pressure sensor 7 ZERO_CROSSING 8 PWM_VALVE 9 VCC 10 GND 1 2 Communication 1 VCC 2 3 4 CT 1 2 3 5 12V 6 7 8 9 10 RELAY 1 2 3 4 5 11 12 13 3phase detect 14 GND 1 12V 2 GND CN92 MAIN TO BLDC CN31 Communication CN13 Transmitter DC Power 12V CN42 MAIN TO HUB CN33 Comm Inspection CN41 MAINTO CT CN12 DC power for backup tool OPT1 MODE SELECTOR CN85 Check condition CN22 Download using ...

Page 394: ...PCB Diagram and Parts List 6 47 Samsung Electronics 6 2 3 ASS Y PCB MAIN HUB AC 1 2 3 4 5 7 9 11 13 15 17 6 8 10 12 14 16 9 6 B B a LQGG ...

Page 395: ...H1 L 2 N 1 ACCUM CCH L 2 N 1 LIQUID1 L 2 N 1 LIQUID1 L 2 N 1 OD EEV L 2 N 1 EVI L 2 N 1 HOTGAS L 2 N 1 COOLING L 2 N 1 OILGAS L 2 N 1 4WAY L 2 N 1 PWM L 2 N CN701 High Pressure S W CN70 AC 220V CN91 1 EVI1 2 3 V V CN75 OIL1 2 3 V V CN73 CCH3 V V CN72 CCH2V V CN71 CCH1 V V CN74 ACCUM CCH V V CN85 LIQUID1 V V CN86 LIQUID2V V CN88 OD EEV V V HOTGAS V V COOLINGV V OILGAS V V PWM V V CN89 EVI V V 4WAY ...

Page 396: ...PCB Diagram and Parts List 6 49 Samsung Electronics 18 21 22 24 26 27 25 28 29 30 31 32 23 19 20 ASS Y PCB MAIN HUB cont DC 9 6 B B a LQGG ...

Page 397: ...GE 5 SUCTION1 6 SUCTION1 7 LIQUID 8 LIQUID 1 COMP1 SUMP 2 COMP1 SUMP 3 EVI IN 4 EVI IN 5 EVI OUT 6 EVI OUT 7 SUCTION2 8 SUCTION2 1 Signal 1 2 Signal 2 3 Signal 3 4 Signal 4 5 12V 1 Signal 1 2 Signal 2 3 Signal 3 4 Signal 4 5 12V 1 Signal 1 2 Signal 2 3 Signal 3 4 Signal 4 5 12V 1 Signal 1 2 Signal 2 3 Signal 3 4 Signal 4 5 12V 1 VCC 2 MODE 3 RESET 4 Signal 1 5 Signal 2 6 Signal 3 7 GND 1 Comm RX 2...

Page 398: ...PCB Diagram and Parts List 6 51 Samsung Electronics 6 2 4 ASS Y BLDC EMI DRIVER RD HHXGA RD HRXGA Series 3 2 4 5 6 7 1 9 6 B B a LQGG ...

Page 399: ... 5V 3 SIGNAL V 4 DGND 5 SIGNAL W 6 OVER TEMP SIGNAL 7 DGND 1 SIGNAL U 2 5V 3 SIGNAL V 4 DGND 5 SIGNAL W 6 OVER TEMP SIGNAL 7 DGND 1 12V 2 GND 3 5V 4 FAN SIGNAL 1 FAN 5 FAN FEEDBACK 1 FAN 6 FAN SIGNAL 2 FAN 7 FAN FEEDBACK 2 FAN 8 INRUSH 1 L 2 N 1 GND CN301 MOTOR 2 CN302 MOTOR 1 CN101 MOTOR SIGNAL 1 CN201 MOTOR SIGNAL 2 CN501 BLDC TO MAIN CN401 AC 220V CN702 EARTH 9 6 B B a LQGG ...

Page 400: ...PCB Diagram and Parts List 6 53 Samsung Electronics 6 2 5 ASS Y BLDC EMI DRIVER RD HHXGB RD HRXGB Series 3 4 5 2 6 7 1 9 6 B B a LQGG ...

Page 401: ...AL U 2 5V 3 SIGNAL V 4 DGND 5 SIGNAL W 6 OVER TEMP SIGNAL 7 DGND 1 SOGNAL U 2 5V 3 SIGNAL V 4 DGND 5 SIGNAL W 6 OVER TEMP SIGNAL 7 DGND 1 12V 2 GND 3 5V 4 FAN SIGNAL 1 FAN 5 FAN FEEDBAC 1 FAN 6 FAN SIGNAL 2 FAN 7 FAN FEEDBACK 2 FAN 8 INRUSH 1 L 2 N 1 GND CN301 MOTOR OUTPUT 2 FAN CN302 MOTOR OUTPUT 1 FAN CN101 MOTOR SIGNAL 1 FAN CN201 MOTOR SIGNAL 2 FAN CN501 BLDC TO MAIN CN401 AC 220V CN702 EARTH ...

Page 402: ...PCB Diagram and Parts List 6 55 Samsung Electronics 6 2 6 ASS Y PCB SUB SENSOR CT UP 3 5 6 7 8 1 4 2 9 6 B B a LQGG ...

Page 403: ...RELAY2 Signal 8 RELAY3 Signal 9 RELAY4 Signal 10 RELAY5 Signal 11 3phase Signal R 12 3phase Signal S 13 3phase SignalT 14 GND 1 5V 2 COMP3 Current SENSING 3 RELAY4 Signal 4 RELAY5 Signal 5 12V 6 GND 1 R 3 S 5 T 1 R 2 S 3 T 1 R 2 S 3 T 1 R 3 S 5 T CN201 COMP2 Power CN101 COMP1 Power CN401 UP CT TO LOW CT CN402 CT TO MAIN CN103 COMP1 Power Factor Compensation CN102 COMP1 Power CN202 COMP2 Power CN20...

Page 404: ...ronics 1 5V 2 COMP3 Current SENSING 3 RELAY4 Signal 4 RELAY5 Signal 5 12V 6 GND 1 R 2 S 3 T 1 R 2 S 3 T 1 R 3 S 5 T CN201 COMP2 Power CN101 COMP1 Power CN401 UP CT TO LOW CT CN402 CT TO MAIN 6 2 7 ASS Y PCB SUB SENSOR CT LOW 1 2 3 4 9 6 B B a LQGG ...

Page 405: ... B C D E F PORT ENABLE ROOM B ROOM C ROOM D ROOM E ROOM F Y G G G G G R HEAT RECOVERY 1 10 CN10_SUB X701 X501 3 4 5 8 9 1 10 12 RY01 PC01 IC01 F701 D101 C101 X702 X502 F702 R103 C103 R104 C105 ON SW07 C107 ON SW08 C108 ON SW09 1 10 CN10 1 2 3 4 5 7 6 ST11 CD11 NTC1 G2 b c e d G1 f a g DIS1 1 2 CN31 G2 b c e d G1 f a g DIS2 SW10 1 SW06 1 SW05 1 SW04 1 SW03 1 SW02 1 SW01 1 4 1 CN41 4 1 CN42 1 2 CN49...

Page 406: ...54A LED DISPLAY SSD A3202GS A13 LED DISPLAY 2 DIGIT 1 1 SNA 16 SEGMENT 2 DIGIT 16 6x16x13mm GREEN 50mW 9 DP52 DB07 00054A LED DISPLAY SSD A3202GS A13 LED DISPLAY 2 DIGIT 1 1 SNA 16 SEGMENT 2 DIGIT 16 6x16x13mm GREEN 50mW 9 C102 2401 000287 C AL 100uF 20 16V WT TP 6 3x11 5 1 1 SNA C211 2401 000287 C AL 100uF 20 16V WT TP 6 3x11 5 1 1 SNA C131 2401 000733 C AL 2200uF 20 35V WT TP 16x25 7 5 1 1 SNA C...

Page 407: ... D532 0401 001099 DIODE SWITCHING 1N4148WS 75V 150mA SOD 323 TP 1 1 SNA D533 0401 001099 DIODE SWITCHING 1N4148WS 75V 150mA SOD 323 TP 1 1 SNA D534 0401 001099 DIODE SWITCHING 1N4148WS 75V 150mA SOD 323 TP 1 1 SNA D541 0401 001099 DIODE SWITCHING 1N4148WS 75V 150mA SOD 323 TP 1 1 SNA D542 0401 001099 DIODE SWITCHING 1N4148WS 75V 150mA SOD 323 TP 1 1 SNA D543 0401 001099 DIODE SWITCHING 1N4148WS 75...

Page 408: ...5 5uA ST 1 1 SNA R202 2007 000043 R CHIP 1Kohm 1 1 10W TP 1608 1 1 SNA R315 2007 000070 R CHIP 0ohm 5 1 10W TP 1608 1 1 SNA R340 2007 000070 R CHIP 0ohm 5 1 10W TP 1608 1 1 SNA R420 2007 000074 R CHIP 100ohm 5 1 10W TP 1608 1 1 SNA R421 2007 000074 R CHIP 100ohm 5 1 10W TP 1608 1 1 SNA R205 2007 000078 R CHIP 1Kohm 5 1 10W TP 1608 1 1 SNA R303 2007 000078 R CHIP 1Kohm 5 1 10W TP 1608 1 1 SNA R304 ...

Page 409: ...000090 R CHIP 10Kohm 5 1 10W TP 1608 1 1 SNA R203 2007 000097 R CHIP 47Kohm 5 1 10W TP 1608 1 1 SNA R204 2007 000097 R CHIP 47Kohm 5 1 10W TP 1608 1 1 SNA R201 2007 000116 R CHIP 120ohm 5 1 10W TP 1608 1 1 SNA R335 2007 000116 R CHIP 120ohm 5 1 10W TP 1608 1 1 SNA R336 2007 000116 R CHIP 120ohm 5 1 10W TP 1608 1 1 SNA R401 2007 000763 R CHIP 330ohm 1 1 10W TP 1608 1 1 SNA R403 2007 000763 R CHIP 3...

Page 410: ...203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 1 SNA C209 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 1 SNA C212 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 1 SNA C213 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 1 SNA C214 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 1 SNA C216 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 1 SNA C304 2203 005249 C CER CHIP 100nF 10 50V...

Page 411: ...VMPLUS4 UP FR 4 T1 6 2 600 1 1 SNA IC04 DB91 01136A ASSY MIC DVM Plus4 V UP Out Main Micom STM 1008 OS 1 1 SNA S3F4A1H 100TQFP RAM 512KB K1 DB98 19891A ASSY TACT SWITCH 12V 50mA SMD 6x6mm actuator 4 3mm 1 1 SNA K2 DB98 19891A ASSY TACT SWITCH 12V 50mA SMD 6x6mm actuator 4 3mm 1 1 SNA K3 DB98 19891A ASSY TACT SWITCH 12V 50mA SMD 6x6mm actuator 4 3mm 1 1 SNA K4 DB98 19891A ASSY TACT SWITCH 12V 50mA ...

Page 412: ... FUSE CARTRIDGE 250V 2A TIME LAG GLASS 5x20mm 1 SNA F902 1 3601 000248 FUSE CARTRIDGE 250V 2A TIME LAG GLASS 5x20mm 1 SNA F901 3602 001012 FUSE BLOCK 500V 100MOhm 1 SNA F902 3602 001012 FUSE BLOCK 500V 100MOhm 1 SNA CN701 3711 000176 HEADER BOARD TO CABLE 1WALL 2P 1R 3 96mm STRAIGHT SN BLU 1 SNA CN83 3711 000203 HEADER BOARD TO CABLE 1WALL 2P 3P 1R 7 92mm STRAIGHT SN WHT 1 SNA CN75 3711 000360 CON...

Page 413: ...C210 2401 000037 C AL 470uF 20 16V GP TP 8x11 5 5 1 SNA C216 2401 000037 C AL 470uF 20 16V GP TP 8x11 5 5 1 SNA C207 2401 000151 C AL 1000uF 20 25V GP TP 10x20 5 1 SNA C232 2401 000151 C AL 1000uF 20 25V GP TP 10x20 5 1 SNA C613 2401 000287 C AL 100uF 20 16V WT TP 6 3x11 5 1 SNA C611 2401 000303 C AL 100uF 20 25V WT TP 6 3x11mm 5mm 1 SNA C206 2401 000480 C AL 10uF 20 50V GP TP 5x11 5 1 SNA C213 24...

Page 414: ... CHIP 330ohm 5 1 10W TP 1608 1 SNA R422 2007 000076 R CHIP 330ohm 5 1 10W TP 1608 1 SNA R446 2007 000076 R CHIP 330ohm 5 1 10W TP 1608 1 SNA R208 2007 000077 R CHIP 470ohm 5 1 10W TP 1608 1 SNA R522 2007 000078 R CHIP 1Kohm 5 1 10W TP 1608 1 SNA R521 2007 000090 R CHIP 10Kohm 5 1 10W TP 1608 1 SNA R600 2007 000090 R CHIP 10Kohm 5 1 10W TP 1608 1 SNA R601 2007 000090 R CHIP 10Kohm 5 1 10W TP 1608 1...

Page 415: ...TP 1608 1 SNA R408 2007 000763 R CHIP 330ohm 1 1 10W TP 1608 1 SNA R442 2007 000763 R CHIP 330ohm 1 1 10W TP 1608 1 SNA R443 2007 000763 R CHIP 330ohm 1 1 10W TP 1608 1 SNA R833 2007 000869 R CHIP 4 7Kohm 1 1 10W TP 1608 1 SNA R513 2007 000944 R CHIP 47Kohm 5 1 4W TP 3216 1 SNA R514 2007 000944 R CHIP 47Kohm 5 1 4W TP 3216 1 SNA R515 2007 000944 R CHIP 47Kohm 5 1 4W TP 3216 1 SNA R516 2007 000944 ...

Page 416: ...TP 1608 1 SNA C421 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 SNA C422 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 SNA C603 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 SNA C604 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 SNA C605 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 SNA C606 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 SNA C607 2203 005249 C CER CHIP 100n...

Page 417: ...t Hub Micom STM 1009 OS S3F4A1H 1 SNA 100TQFP RAM 512KB 0011 DB09 00535A IC MICOM S3F4A1H 100P DC5V 12 MHz TQFP 16 Bit 16 Bit TQFP QFP 1 SNA 16 Bit 40 105 512K ASSY HEAT SINK DB95 04699A ASSY HEAT SINK DVMPLUS4 UP HUB PBA 1 SNA 001 0404 001489 DIODE SCHOTTKY SBR20A200CTFP 200V 20000mA ITO 220AB ST 1 SNA 001 6002 000630 SCREW TAPPING PH 2S M3 L8 ZPC WHT SWRCH18A 1 SNA 001 DB62 03581A HEAT SINK DPM ...

Page 418: ...OWER 12V 200mW 5000mA 1FormA 10ms 10ms 0 1 SNA RY93 3501 001264 RELAY POWER 12V 200mW 5000mA 1FormA 10ms 10ms 0 1 SNA RY93 3501 001264 RELAY POWER 12V 200mW 5000mA 1FormA 10ms 10ms 0 1 SNA SS71 3502 000115 SSR 12V 2A 1ms 1ms 1 1 SNA F901 1 3601 000248 FUSE CARTRIDGE 250V 2A TIME LAG GLASS 5x20mm 1 1 SNA F902 1 3601 000248 FUSE CARTRIDGE 250V 2A TIME LAG GLASS 5x20mm 1 1 SNA F901 3602 001012 FUSE B...

Page 419: ...ARBON S 22ohm 5 1 2W AA TP 2 4x6 4mm 1 1 SNA R270 2001 000020 R CARBON S 22ohm 5 1 2W AA TP 2 4x6 4mm 1 1 SNA R281 2001 000020 R CARBON S 22ohm 5 1 2W AA TP 2 4x6 4mm 1 1 SNA C220 2201 000285 C CERAMIC DISC 1nF 10 1000V Y5P 8x5mm 5mm 1 1 SNA C221 2201 000285 C CERAMIC DISC 1nF 10 1000V Y5P 8x5mm 5mm 1 1 SNA C270 2201 000285 C CERAMIC DISC 1nF 10 1000V Y5P 8x5mm 5mm 1 1 SNA C251 2201 000987 C CERAM...

Page 420: ...SNA R901 2007 000074 R CHIP 100ohm 5 1 10W TP 1608 1 1 SNA R902 2007 000074 R CHIP 100ohm 5 1 10W TP 1608 1 1 SNA R416 2007 000076 R CHIP 330ohm 5 1 10W TP 1608 1 1 SNA R417 2007 000076 R CHIP 330ohm 5 1 10W TP 1608 1 1 SNA R418 2007 000076 R CHIP 330ohm 5 1 10W TP 1608 1 1 SNA R419 2007 000076 R CHIP 330ohm 5 1 10W TP 1608 1 1 SNA R420 2007 000076 R CHIP 330ohm 5 1 10W TP 1608 1 1 SNA R421 2007 0...

Page 421: ... TP 3216 1 1 SNA R216 2007 000614 R CHIP 24Kohm 1 1 10W TP 1608 1 1 SNA R401 2007 000614 R CHIP 24Kohm 1 1 10W TP 1608 1 1 SNA R410 2007 000614 R CHIP 24Kohm 1 1 10W TP 1608 1 1 SNA R440 2007 000614 R CHIP 24Kohm 1 1 10W TP 1608 1 1 SNA R405 2007 000763 R CHIP 330ohm 1 1 10W TP 1608 1 1 SNA R406 2007 000763 R CHIP 330ohm 1 1 10W TP 1608 1 1 SNA R407 2007 000763 R CHIP 330ohm 1 1 10W TP 1608 1 1 SN...

Page 422: ...406 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 1 SNA C407 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 1 SNA C408 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 1 SNA C409 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 1 SNA C410 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 1 SNA C411 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 1 SNA C420 2203 005249 C CER CHIP 100nF 1...

Page 423: ...nF 10 25V X5R TP 1608 1 1 SNA X501 2802 001165 RESONATOR CERAMIC 4MHz 0 5 TP 4 5x2 0x1 15mm 1 1 SNA BEAD200 3301 001120 BEAD SMD 30 2012 TP 1 1 SNA PCB DB41 01026A PCB MAIN HUB DVMPLUS4 UP FR 4 T1 6 2 600 1 1 SNA IC04 DB91 01137A ASSY MIC DVM Plus4 V UP Out Hub Micom STM 1009 OS 1 1 SNA S3F4A1H 100TQFP RAM 512KB ASSY HEAT SINK DB95 04699A ASSY HEAT SINK DVMPLUS4 UP HUB PBA 1 1 SNA 001 0404 001489 ...

Page 424: ...N BLU 0 1 SNA CN101 3711 001082 HEADER BOARD TO CABLE BOX 7P 1R 2 5MM STRAIGHT SN WHT 1 1 SNA CN501 3711 004712 HEADER BOARD TO CABLE BOX 9P 1R 2mm STRAIGHT SN WHT 1 1 SNA CN401 3711 007649 CONNECTOR HEADER 2 1R 10mm STRAIGHT BRASS BLK 1 1 SNA IC301 4719 002484 POWER MODULE Smart Power Module FNA41560B2 600V 15A 41W 20kHz 1 1 SNA IC302 4719 002484 POWER MODULE Smart Power Module FNA41560B2 600V 15...

Page 425: ...1548 C AL 47uF 20 25V WT TP 5x11 5 0 1 SNA C611 2401 003036 C AL 100uF 20 16V GP TP 5X11mm 5mm 1 1 SNA C613 2401 003036 C AL 100uF 20 16V GP TP 5X11mm 5mm 1 1 SNA CE405 2401 003585 C AL 220uF 20 35V WT TP 8x11 5mm 5 1 1 SNA CE425 2401 003585 C AL 220uF 20 35V WT TP 8x11 5mm 5 0 1 SNA C703 2401 003617 C AL 680uF 20 400V WT BK 35x50mm 10 0 1 SNA C704 2401 003617 C AL 680uF 20 400V WT BK 35x50mm 10 0...

Page 426: ... 55mm 1 1 SNA LD603 0601 001816 LED SMD Y GRN 1 6X0 8X0 55MM 570NM 1 6x0 8x0 55mm 1 1 SNA LD502 0601 002345 LED SMD RED 1 6x0 8x0 55mm 660nm 1 6x0 8x0 55mm 1 1 SNA LD503 0601 002345 LED SMD RED 1 6x0 8x0 55mm 660nm 1 6x0 8x0 55mm 1 1 SNA LD522 0601 002345 LED SMD RED 1 6x0 8x0 55mm 660nm 1 6x0 8x0 55mm 0 1 SNA LD523 0601 002345 LED SMD RED 1 6x0 8x0 55mm 660nm 1 6x0 8x0 55mm 0 1 SNA PC501 0604 001...

Page 427: ...0 1 SNA R508 2007 000080 R CHIP 2Kohm 5 1 10W TP 1608 1 1 SNA R527 2007 000080 R CHIP 2Kohm 5 1 10W TP 1608 0 1 SNA R528 2007 000080 R CHIP 2Kohm 5 1 10W TP 1608 0 1 SNA R608 2007 000080 R CHIP 2Kohm 5 1 10W TP 1608 1 1 SNA R604 2007 000084 R CHIP 4 7Kohm 5 1 10W TP 1608 1 1 SNA R532 2007 000090 R CHIP 10Kohm 5 1 10W TP 1608 0 1 SNA R562 2007 000090 R CHIP 10Kohm 5 1 10W TP 1608 1 1 SNA R813 2007 ...

Page 428: ...8W TP 2012 1 1 SNA R108 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 1 SNA R109 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 1 SNA R127 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 0 1 SNA R128 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 0 1 SNA R129 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 0 1 SNA R801 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 1 SNA R815 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 1 SNA R818 2007 ...

Page 429: ...1608 0 1 SNA ER14 2007 000924 R CHIP 470Kohm 1 1 4W TP 3216 1 1 SNA ER15 2007 000924 R CHIP 470Kohm 1 1 4W TP 3216 1 1 SNA ER24 2007 000924 R CHIP 470Kohm 1 1 4W TP 3216 0 1 SNA ER25 2007 000924 R CHIP 470Kohm 1 1 4W TP 3216 0 1 SNA R205 2007 000928 R CHIP 470ohm 1 1 8W TP 2012 1 1 SNA R225 2007 000928 R CHIP 470ohm 1 1 8W TP 2012 0 1 SNA R808 2007 000941 R CHIP 47Kohm 5 1 8W TP 2012 1 1 SNA R828 ...

Page 430: ...F 80 20 50V Y5V TP 2012 1 1 SNA C808 2203 000192 C CER CHIP 100nF 80 20 50V Y5V TP 2012 1 1 SNA C811 2203 000192 C CER CHIP 100nF 80 20 50V Y5V TP 2012 1 1 SNA C812 2203 000192 C CER CHIP 100nF 80 20 50V Y5V TP 2012 1 1 SNA C813 2203 000192 C CER CHIP 100nF 80 20 50V Y5V TP 2012 1 1 SNA C828 2203 000192 C CER CHIP 100nF 80 20 50V Y5V TP 2012 0 1 SNA C831 2203 000192 C CER CHIP 100nF 80 20 50V Y5V ...

Page 431: ...C CER CHIP 100nF 10 50V X7R TP 1608 0 1 SNA C423 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 0 1 SNA C428 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 0 1 SNA C806 2203 005261 C CER CHIP 1000nF 10 25V X7R TP 3216 1 1 SNA C807 2203 005261 C CER CHIP 1000nF 10 25V X7R TP 3216 1 1 SNA C826 2203 005261 C CER CHIP 1000nF 10 25V X7R TP 3216 0 1 SNA C827 2203 005261 C CER CHIP 1000nF 10 25V X7R TP...

Page 432: ...000630 SCREW TAPPING PH NO 2S M3 L8 ZPC WHT SWRCH18A 1 1 SNA DB62 04075A HEAT SINK DVMPLUS2 A6023 1 20 32 4 WHT SJ 052 0 678kg m 21 1 1 SNA DB98 16586A ASSY DIODE 600V GS1B2560 600V 25A 1 1 SNA Location No Code No Description Specification SA SNA DB93 11624C DB93 11624D 9 6 B B a LQGG ...

Page 433: ...76 CONNECTOR HEADER 3P 1R 10mm STRAIGHT AU BLK 1 SNA CN102 3711 007276 CONNECTOR HEADER 3P 1R 10mm STRAIGHT AU BLK 1 SNA CN201 3711 007276 CONNECTOR HEADER 3P 1R 10mm STRAIGHT AU BLK 1 SNA CN202 3711 007276 CONNECTOR HEADER 3P 1R 10mm STRAIGHT AU BLK 1 SNA FUSE COVER DB63 02452A COVER FUSE DVM PLUS4 ABS BLACK SC 90073R 5VA 2 SNA R401 2009 001233 R METAL GLAZE 200Kohm 5 2W AA TP 4x12mm 1 SNA R402 2...

Page 434: ... CHIP 3 3Kohm 5 1 10W TP 1608 1 SNA R804 2007 000082 R CHIP 3 3Kohm 5 1 10W TP 1608 1 SNA R805 2007 000082 R CHIP 3 3Kohm 5 1 10W TP 1608 1 SNA R101 2007 000084 R CHIP 4 7Kohm 5 1 10W TP 1608 1 SNA R102 2007 000084 R CHIP 4 7Kohm 5 1 10W TP 1608 1 SNA R201 2007 000084 R CHIP 4 7Kohm 5 1 10W TP 1608 1 SNA R202 2007 000084 R CHIP 4 7Kohm 5 1 10W TP 1608 1 SNA R407 2007 000090 R CHIP 10Kohm 5 1 10W T...

Page 435: ...1 SNA C202 2203 000440 C CER CHIP 1nF 10 50V X7R TP 1608 1 SNA C801 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 SNA CT101 3201 001920 SENSOR MAG ACS710KLATR 25CB T 40 to 125C 5V 25A 1 SNA CT201 3201 001920 SENSOR MAG ACS710KLATR 25CB T 40 to 125C 5V 25A 1 SNA PCB DB41 01037A PCB SUB SENSOR DVMPLUS4 UP FR 4 T1 6 1 600 1 SNA Location No Code No Description Specification SA SNA Remark 9 6 B B a...

Page 436: ...T SN NTR 1 SNA CN301 3711 007276 CONNECTOR HEADER 3P 1R 10mm STRAIGHT AU BLK 1 SNA CN302 3711 007276 CONNECTOR HEADER 3P 1R 10mm STRAIGHT AU BLK 1 SNA FUSE COVER DB63 02452A COVER FUSE DVM PLUS4 ABS BLACK SC 90073R 5VA 1 SNA D301 0401 001099 DIODE SWITCHING 1N4148WS 75V 150mA SOD 323 TP 1 SNA D302 0401 001099 DIODE SWITCHING 1N4148WS 75V 150mA SOD 323 TP 1 SNA ZD301 0403 000258 DIODE ZENER BZX84C5...

Page 437: ...TP SNA 1 D938 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP SNA 1 D939 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP SNA 1 D940 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP SNA 1 D941 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP SNA 1 D942 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP SNA 1 D943 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP S...

Page 438: ...979 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP SNA 1 D980 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP SNA 1 D981 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP SNA 1 D982 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP SNA 1 D983 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP SNA 1 D984 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP SNA 1 D985 ...

Page 439: ...RRAY 2003 NPN 7 1W SOP 16 ST 1000 SNA 1 IC16 0506 000175 TR ARRAY 2003 NPN 7 1W SOP 16 ST 1000 SNA 1 LED6 0601 001373 LED ROUND RED 3PI 630nm 3 8x5 3mm SNA 1 LED1 0601 001375 LED ROUND GRN 3mm 570nm 3 8x5 3mm SNA 1 LED12 0601 001375 LED ROUND GRN 3mm 570nm 3 8x5 3mm SNA 1 LED2 0601 001375 LED ROUND GRN 3mm 570nm 3 8x5 3mm SNA 1 LED3 0601 001375 LED ROUND GRN 3mm 570nm 3 8x5 3mm SNA 1 LED4 0601 001...

Page 440: ...R CHIP 10Kohm 5 1 8W TP 2012 SNA 1 R404 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 SNA 1 R905 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 SNA 1 R906 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 SNA 1 R907 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 SNA 1 R908 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 SNA 1 R909 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 SNA 1 R910 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 SNA 1 R...

Page 441: ...Y5V TP 2012 SNA 1 C08 2203 000192 C CER CHIP 100nF 80 20 50V Y5V TP 2012 SNA 1 C09 2203 000192 C CER CHIP 100nF 80 20 50V Y5V TP 2012 SNA 1 C10 2203 000192 C CER CHIP 100nF 80 20 50V Y5V TP 2012 SNA 1 C102 2203 000192 C CER CHIP 100nF 80 20 50V Y5V TP 2012 SNA 1 C104 2203 000192 C CER CHIP 100nF 80 20 50V Y5V TP 2012 SNA 1 C11 2203 000192 C CER CHIP 100nF 80 20 50V Y5V TP 2012 SNA 1 C110 2203 0001...

Page 442: ...V TP 2012 SNA 1 C302 2203 001562 C CER CHIP 10nF 80 20 50V Y5V TP 2012 SNA 1 C303 2203 001562 C CER CHIP 10nF 80 20 50V Y5V TP 2012 SNA 1 C905 2203 001562 C CER CHIP 10nF 80 20 50V Y5V TP 2012 SNA 1 C906 2203 001562 C CER CHIP 10nF 80 20 50V Y5V TP 2012 SNA 1 C907 2203 001562 C CER CHIP 10nF 80 20 50V Y5V TP 2012 SNA 1 C908 2203 001562 C CER CHIP 10nF 80 20 50V Y5V TP 2012 SNA 1 C909 2203 001562 C...

Page 443: ... 3501 001154 RELAY MINIATURE 12V 200mW 3000mA 1FormA 10ms 10ms SA 1 RY75 3501 001154 RELAY MINIATURE 12V 200mW 3000mA 1FormA 10ms 10ms SA 1 RY76 3501 001154 RELAY MINIATURE 12V 200mW 3000mA 1FormA 10ms 10ms SA 1 RY77 3501 001154 RELAY MINIATURE 12V 200mW 3000mA 1FormA 10ms 10ms SA 1 RY78 3501 001154 RELAY MINIATURE 12V 200mW 3000mA 1FormA 10ms 10ms SA 1 RY79 3501 001154 RELAY MINIATURE 12V 200mW 3...

Page 444: ...m STRAIGHT SN BLK SNA 1 DIS1 DB07 00054A LED DISPLAY SSD A3202GS A13 LED DISPLAY 2 DIGIT 16 SEGMENT 2 SNA 1 DIGIT 16 6x16x13mm GREEN 50mW 9 DIS2 DB07 00054A LED DISPLAY SSD A3202GS A13 LED DISPLAY 2 DIGIT 16 SEGMENT 2 SNA 1 DIGIT 16 6x16x13mm GREEN 50mW 9 ST11 DB26 00015A TRANS SWITCHING JT1916 09 310V FERRITE EI1916 130KHZ 1 65MH SNA 1 SHIELD FT71 DB27 00019A COIL CHOKE SSC1905200B Line Filter 20...

Page 445: ...Slim 1way cassette type AVXCSH022 028 036E ND022 028 0361H This Document can not be used without Samsung s authorization Fan Motor Part Indoor Eva In Out Sensor Part Drain Pump Part Display Part Float S W Part EEV Control Part Rouver Control Part 9 6 B B LQGG ...

Page 446: ...tronics Panel Display Part Slim 1way cassette type cont ND0561 0711HXE Series This Document can not be used without Samsung s authorization Indoor Eva In Out Sensor Part Rouver Control Part Fan Motor Part Drain Pump Part 9 6 B B LQGG ...

Page 447: ...2 2way cassette type Fan Motor 1 Part Display Part Indoor Eva In Eva Out Sensor Part Float S W Part This Document can not be used without Samsung s authorization EEV Control Part Drain Pump Part Fan Motor 2 Part Rouver Control Part 9 6 B B LQGG ...

Page 448: ...onics 7 1 3 4way cassette type This Document can not be used without Samsung s authorization Indoor Eva In Eva Out Sensor Part Display Part Rouver Control Part Fan Motor Part Float S W Part EEV Control Part Drain Pump Part 9 6 B B LQGG ...

Page 449: ... 5 7 1 4 Mini 4way cassette type This Document can not be used without Samsung s authorization Indoor Eva In Eva Out Sensor Part Display Part Rouver Control Part Fan Motor Part Float S W Part EEV Control Part Drain Pump Part 9 6 B B LQGG ...

Page 450: ...DUCT type Slim I II AVXDSH022 028 036 045 056 071E ND022 028 036 045 056 071L This Document can not be used without Samsung s authorization Indoor Eva In Eva Out Sensor Part Display Part Fan Motor Part EEV Control Part Float S W Part 9 6 B B LQGG ...

Page 451: ...onics 7 7 7 1 6 DUCT type Slim III AVXDSH090 112 128 140E ND0090 122 128 140L This Document can not be used without Samsung s authorization Indoor Eva In Eva Out Sensor Part Display Part Fan Motor Part EEV Control Part 9 6 B B LQGG ...

Page 452: ...g Diagram 7 8 Samsung Electronics 7 1 7 DUCT type MSP Indoor Eva In Eva Out Sensor Part Display Part Fan Motor Part EEV Control Part This Document can not be used without Samsung s authorization 9 6 B B LQGG ...

Page 453: ...g Diagram Samsung Electronics 7 9 7 1 8 DUCT type HSP Indoor Eva In Eva Out Sensor Part EEV Control Part Display Part Fan Motor Part This Document can not be used without Samsung s authorization 9 6 B B LQGG ...

Page 454: ...Wiring Diagram 7 10 Samsung Electronics 7 1 9 DUCT type SUPER Indoor Eva In Eva Out Sensor Part EEV Control Part Fan Motor Part This Document can not be used without Samsung s authorization 9 6 B B LQGG ...

Page 455: ...ung Electronics 7 11 7 1 10 DUCT type BIG Motor Part Main PBA EEV Control Part Sensor Part Sensor Part BLDC PBA Motor Control EMI PBA Power Input This Document can not be used without Samsung s authorization 9 6 B B LQGG ...

Page 456: ...m 7 12 Samsung Electronics 7 1 11 Ceiling Indoor Eva In Eva Out Sensor Part Display Part Fan Motor Part EEV Control Part This Document can not be used without Samsung s authorization Rouver Control Part 9 6 B B LQGG ...

Page 457: ...cs 7 13 7 1 12 Console This Document can not be used without Samsung s authorization Display Part Damper Part EEV Control Part Rouver Control Part Indoor Eva In Eva Out Sensor Part Ventilator Part Fan Motor Part MPI Part 9 6 B B LQGG ...

Page 458: ...Electronics 7 1 13 Wall Mounted type Montblanc This Document can not be used without Samsung s authorization Display Part Indoor Eva In Eva Out Sensor Part Fan Motor Part MPI Part Auto Grille Part Rouver Control Part 9 6 B B LQGG ...

Page 459: ...g Electronics 7 15 7 1 14 Wall Mounted type Neo Forte without EEV Display Part This Document can not be used without Samsung s authorization Indoor Eva In Eva Out Sensor Part Fan Motor Part Rouver Control Part 9 6 B B LQGG ...

Page 460: ...Electronics 7 1 15 Wall Mounted type Neo Forte with EEV Display Part This Document can not be used without Samsung s authorization Indoor Eva In Eva Out Sensor Part Fan Motor Part Rouver Control Part EEV Control Part 9 6 B B LQGG ...

Page 461: ...7 17 7 1 16 Wall Mounted type Vivace Display Part This Document can not be used without Samsung s authorization Indoor Eva In Eva Out Sensor Part Fan Motor Part Rouver Control Part Auto Grille Part MPI Part EEV Control Part 9 6 B B LQGG ...

Page 462: ...ng Diagram 7 18 Samsung Electronics 7 1 17 Distributor kit This Document can not be used without Samsung s authorization C Room EEV Control Part B Room EEV Control Part A Room EEV Control Part 9 6 B B LQGG ...

Page 463: ...Samsung Electronics 7 19 7 2 Outdoor Unit 7 2 1 Outdoor HP This Document can not be used without Samsung s authorization 9 6 B B LQGG ...

Page 464: ...Wiring Diagram 7 20 Samsung Electronics Outdoor cont HR This Document can not be used without Samsung s authorization 9 6 B B LQGG ...

Page 465: ...Wiring Diagram Samsung Electronics 7 21 7 2 2 MCU Valves Part EEV Control Part This Document can not be used without Samsung s authorization Temp Sensor Part 9 6 B B LQGG ...

Page 466: ...oor Sensor Part Wired Remote Controller Join SMPS Circuit Part Buzzer Circuit Part EEV Circuit Part External Contact Point Control Part Louver Drive Part Slide Panel Drive Part Display Receiving Part Main Adress Setting Switch RMC Adress Setting Switch 485 Comm Part COM1 8 1 This Document can not be used without Samsung s authorization Samsung Electronics 9 6 B B LQGG ...

Page 467: ... not be used without Samsung s authorization Samsung Electronics AC Power Part SMPS Circuit Part External Contact Point Control Part Buzzer Circuit Part EEV Circuit Part Zero Crossing Circuit Part BLDE Fan Drive Part Indoor Sensor Part Motor Drive Part Display Cuicit Part Address Option Setting Switch 9 6 B B LQGG ...

Page 468: ... Diagram Slim 1 way cassette type cont PANEL This Document can not be used without Samsung s authorization Samsung Electronics 8 3 Display LED Part Remocon Signal Receiving Module Timer Fan Filter Operation Deforest 9 6 B B LQGG ...

Page 469: ...s Document can not be used without Samsung s authorization Samsung Electronics 8 4 SMPS Part Zero Crossing Part Motor Control Part Temperature Sensor Part Communication Part EEV Control Part External Control Part Louver Control Part Display Control Part 9 6 B B LQGG ...

Page 470: ...t be used without Samsung s authorization Samsung Electronics 8 5 SMPS Part Loading Part BLCD Fan Motor Control Part Temperature Sensor Part 485 Communication Part EEV SUB PCB Part External Control Part Louver Control Part Display PCB Part Address Option Switch Set Part 9 6 B B LQGG ...

Page 471: ... Crossing Part Motor Control Part Temperature Sensor Part Communication Part EEV Control Part External Control Part Louver Control Part Display Control Part Address Setting Switch Part This Document can not be used without Samsung s authorization Samsung Electronics 8 6 9 6 B B LQGG ...

Page 472: ...Document can not be used without Samsung s authorization Samsung Electronics 8 7 SMPS Part Zero Crossing Part Motor Control Part Temperature Sensor Part Communication Part EEV Control Part External Control Part Display Control Part Address Setting Switch Part 9 6 B B LQGG ...

Page 473: ...UPER SMPS Part Zero Crossing Part Motor Control Part Temperature Sensor Part Communication Part EEV Control Part External Control Part Display Control Part This Document can not be used without Samsung s authorization Samsung Electronics 8 8 9 6 B B LQGG ...

Page 474: ...cument can not be used without Samsung s authorization Samsung Electronics 8 9 SMPS Part Zero Crossing Part Motor Control Part Temperature Sensor Part Communication Part EEV Control Part External Control Part Display Control Part Address Setting Switch Part 9 6 B B LQGG ...

Page 475: ...16 20 13 4 21 9 8 10 11 12 5 6 7 1 2 3 P RTH VTH NU W V IN WL VFO CSC NV NW VS W U IN VL IN UH VCC L VB W VB U COM IN VH IN WH IN UL VS V VB V VS U VCC H 15VDC 0 2W DTA114EKA Q903 2 1 3 O I G PDC310V 0 1W F 3 9K R108 2 1 630V 10nF C101 2 1 KA7805A IC102 2 3 1 IN OUT GND IPM_TH_OUT 0 2W DTA114EKA Q904 2 1 3 O I G 0 1W J 2K R926 2 1 5V AGND 5V 5V 0 2W DTC114EKA Q901 2 1 3 O I G 0 125W J 560 R908 2 1...

Page 476: ... be used without Samsung s authorization Samsung Electronics 8 11 SMPS Part Zero Crossing Part Motor Control Part Temperature Sensor Part Communication Part EEV Control Part External Control Part Louver Control Part Display Control Part Address Setting Switch Part 9 6 B B LQGG ...

Page 477: ... be used without Samsung s authorization Samsung Electronics SMPS Part Zero Crossing Part Motor Control Part MPI Part Temperature Sensor Part Communication Part EEV Control Part Ventilation Part EMI Filter Part Buzzer Part EEPROM Part Louver control Part Display Control Part 9 6 B B LQGG ...

Page 478: ...Schematic Diagram Samsung Electronics 8 13 Console type cont DISPLAY This Document can not be used without Samsung s authorization 9 6 B B LQGG ...

Page 479: ...Schematic Diagram Samsung Electronics 8 14 Console type cont DAMPER This Document can not be used without Samsung s authorization 9 6 B B LQGG ...

Page 480: ...OTOR 8 15 This Document can not be used without Samsung s authorization SMPS Part Zero Crossing Part Motor Control Part MPI Part Temperature Sensor Part Communication Part EEV Control Part Cross wire checking Part Buzzer Part EEPROM Melody Part Louver control Part Display Control Part 9 6 B B LQGG ...

Page 481: ...ace EEV MOTOR 8 16 This Document can not be used without Samsung s authorization SMPS Part Zero Crossing Part Motor Control Part MPI Part Temperature Sensor Part Communication Part EEV Control Part Cross wire checking Part Buzzer Part EEPROM Melody Part Louver control Part Display Control Part 9 6 B B LQGG ...

Page 482: ... Document can not be used without Samsung s authorization Power Supply Part Zero Crossing Detect Part Buzzer Control Part Display Part EEPROM Part Address External Control MICOM Part EEV Control Part Communication Part Cross Wire Check Part Temperature Sensor Part Fan Control Part MICOM Reset Part 9 6 B B LQGG ...

Page 483: ...door Unit 8 2 1 ASS Y PCB MAIN 8 18 Samsung Electronics This Document can not be used without Samsung s authorization Micom part 485 Communication Part 7 Seg Display Part Main Address Switch Part 9 6 B B LQGG ...

Page 484: ...c Diagram 8 19 Samsung Electronics This Document can not be used without Samsung s authorization AC Power Part Micom Part SMPS Part Sensor Control Part Valve Control Part Zero Crossing Part 8 2 2 ASS Y PCB MAIN HUB 9 6 B B LQGG ...

Page 485: ... Samsung Electronics 8 20 This Document can not be used without Samsung s authorization 8 2 3 ASS Y PCB SUB DRIVER AC Power Part EMI Filter Part IPM Control Part Motor Control Part Motor Hall Sensing Part Motor Protect Part 9 6 B B LQGG ...

Page 486: ...matic Diagram Samsung Electronics 8 21 This Document can not be used without Samsung s authorization ASS Y PCB SUB DRIVER cont IPM Input Output part Motor Control Part Motor Hall Sensing Part Motor Protect Part 9 6 B B LQGG ...

Page 487: ...Schematic Diagram Samsung Electronics 8 22 This Document can not be used without Samsung s authorization 8 2 4 ASS Y PCB SUB SENSOR CT UP 3 phase Detect Part Comp Current Sensing Part Comp Relay Control Part 9 6 B B LQGG ...

Page 488: ... Diagram Schematic Diagram Samsung Electronics 8 23 This Document can not be used without Samsung s authorization 8 2 5 ASS Y PCB SUB SENSOR CT LOW Comp Current Sensing Part Comp Relay Control Part 9 6 B B LQGG ...

Page 489: ...on Cooilng Heating 022 2 2 2 5 028 2 8 3 2 036 3 6 4 0 045 4 5 5 0 056 5 6 6 3 071 7 1 8 0 090 9 0 10 0 112 11 2 12 5 128 12 8 13 8 140 14 0 16 0 Products I N D O O R Cassette C Duct D COVERTIBLE T RAC W Mode C O C H P H H P Heater E C O Heater G C O HotWater Heater N Design Indoor Cassette Slim 1 way S 2 way 2 4 way 4 S 4 way M Duct Slim S Mid pressure U RAC Montblanc B Neo Forte N Vivace V CONV ...

Page 490: ...ax U Hydro Unit HYDRO W Water tank Refrigerant R R22 Value S R22 Tender X R410A STD Y R410A DLX W R410A PRM Z R410A Flagship Mode C C O H H P RagingVoltage A 115V 60Hz B 220V 60Hz C 208 230V 60Hz D 200 220V 50Hz E 220 240V 50Hz F 208 230V 60Hz 3phasea G 380 415V 50Hz 3phasea M 127V 50Hz H 380V 60Hz 3phasea J 460V 60Hz 3phasea Version A Z Export S Solar Water Tank Z High efficiency EER mode indoor ...

Page 491: ...ni DVM M DVM PLUS III DVM PLUS III HR V Mode Heat Pump H Heat recovery R Airflow direction Upward airflows T Frontward airflow F Version Export A Z Cacacity x1 10HP 3 Digits Rating voltage 3Ø 380V 60Hz H 3Ø 380 415V 50Hz G 1Ø 220 240V 50Hz E 9 1 2 Outdoor Unit Index for Model Name cont 9 6 B B LQGG ...

Page 492: ... S SLIM G GHP M MINI J HOME D WDVM E GEO P ECO Heating Refrigerant R R22 X R410A Mode C C O H H P R H R T TROPICAL C O Q TROPICAL H P RagingVoltage A 115V 60Hz B 220V 60Hz C 208 230V 60Hz D 200 220V 50Hz E 220 240V 50Hz F 208 230V 60Hz 3phasea G 380 415V 50Hz 3phasea M 127V 50Hz H 380V 60Hz 3phasea J 460V 60Hz 3phasea Version A Z Export MCD Dummy Mockup madel RD H 100 V X F A Buyer Code Index for ...

Page 493: ...temperature sensor of FVI compressor 2 15 AH Crank case heater of accumulator 50 T3 Suction 1 temperature sensor 16 F Reversing solenoid valve 4Way valve 51 T31 Suction 2 temperature sensor 17 V1 PWM solenoid valve 52 T4 Ambient air temperature sensor 18 V2 Hot gas bypass solenoid valve 53 T5 Cond out temperature sensor 19 V3 Oil gas bypass solenoid valve 54 T6 EVI in temperature sensor 20 V4 Liqu...

Page 494: ...ion Compressor FVI Fixed Vapor Injection Compressor Pressure High Low pressure sensor Valve Solenoid V Solenoid valve Oil seperator Oil seperator Expansion Electronic Expansion Valve EEV Accumulator Accumulator Reversing Reversing valve 4 way valve Check Check valve Heat Exchanger Condensing or Evaporating unit Service Service valve Angle ball type Sub cooler Turbo intercooler or Sub cooler Switch...

Page 495: ...Compressor FVI Fixed Vapor Injection Compressor Pressure High Low pressure sensor Valve Solenoid V Solenoid valve Oil seperator Oil seperator Expansion Electronic Expansion Valve EEV Accumulator Accumulator Reversing Reversing valve 4 way valve Check Check valve Heat Exchanger Condensing or Evaporating unit Service Service valve Angle ball type Sub cooler Turbo intercooler or Sub cooler Switch Hea...

Page 496: ... Injection Compressor FVI Fixed Vapor Injection Compressor Pressure High Low pressure sensor Valve Solenoid V Solenoid valve Oil seperator Oil seperator Expansion Electronic Expansion Valve EEV Accumulator Accumulator Reversing Reversing valve 4 way valve Check Check valve Heat Exchanger Condensing or Evaporating unit Service Service valve Angle ball type Sub cooler Turbo intercooler or Sub cooler...

Page 497: ...or Injection Compressor FVI Fixed Vapor Injection Compressor Pressure High Low pressure sensor Valve Solenoid V Solenoid valve Oil seperator Oil seperator Expansion Electronic Expansion Valve EEV Accumulator Accumulator Reversing Reversing valve 4 way valve Check Check valve Heat Exchanger Condensing or Evaporating unit Service Service valve Angle ball type Sub cooler Turbo intercooler or Sub cool...

Page 498: ...Injection Compressor FVI Fixed Vapor Injection Compressor Pressure High Low pressure sensor Valve Solenoid V Solenoid valve Oil seperator Oil seperator Expansion Electronic Expansion Valve EEV Accumulator Accumulator Reversing Reversing valve 4 way valve Check Check valve Heat Exchanger Condensing or Evaporating unit Service Service valve Angle ball type Sub cooler Turbo intercooler or Sub cooler ...

Page 499: ...ital Vapor Injection Compressor FVI Fixed Vapor Injection Compressor Pressure High Low pressure sensor Valve Solenoid V Solenoid valve Oil seperator Oil seperator Expansion Electronic Expansion Valve EEV Accumulator Accumulator Reversing Reversing valve 4 way valve Check Check valve Heat Exchanger Condensing or Evaporating unit Service Service valve Angle ball type Sub cooler Turbo intercooler or ...

Page 500: ...ling Operation Unit Outdoor Unit Indoor Unit Outdoor Unit Cooling operation Heating operation RROLQJ RROLQJ RROLQJ V V RROLQJ V V V ª RROLQJ V V V V V V RZ WHPSHUDWXUH SUHVVXUH JDV RROLQJ RZ WHPSHUDWXUH SUHVVXUH OLTXLG LJK WHPSHUDWXUH SUHVVXUH JDV LJK WHPSHUDWXUH SUHVVXUH OLTXLG S S J 9 6 B B LQGG ...

Page 501: ...ting Operation Unit Outdoor Unit Indoor Unit Outdoor Unit Cooling operation Heating operation HDWLQJ HDWLQJ HDWLQJ V V ª HDWLQJ V V V HDWLQJ V V V V V V RZ WHPSHUDWXUH SUHVVXUH JDV HDWLQJ RZ WHPSHUDWXUH SUHVVXUH OLTXLG LJK WHPSHUDWXUH SUHVVXUH JDV LJK WHPSHUDWXUH SUHVVXUH OLTXLG S S J 9 6 B B LQGG ...

Page 502: ...ation Main heating operation Cycle Operation Mode cont DVM PLUS 4 Europe Type H R Cooling Operation V V V RROLQ J V V V V V RROLQ J J V V V V V V RROLQ J V V V V V V ª V V V V RROLQ J V V V V RROLQ J RZ WHPSHUDWXUH SUHVVXUH OLTXLG LJK WHPSHUDWXUH SUHVVXUH JDV L K W W OL LG RZ WHPSHUDWXUH SUHVVXUH JDV RROLQ J LJK WHPSHUDWXUH SUHVVXUH OLTXLG 9 6 B B LQGG ...

Page 503: ...peration Main heating operation Cycle Operation Mode cont DVM PLUS 4 Europe Type H R Main Cooling Operation V V V V ծ կ RROLQJ V V V V V V V RROLQJ V V V V V RROLQJ V V V V V V ª V V V ձ հ HDWLQ J V V V RROLQJ RZ WHPSHUDWXUH SUHVVXUH OLTXLG LJK WHPSHUDWXUH SUHVVXUH JDV LJK WHPSHUDWXUH SUHVVXUH OLTXLG RZ WHPSHUDWXUH SUHVVXUH JDV HDWLQ J 9 6 B B LQGG ...

Page 504: ...peration Main heating operation Cycle Operation Mode cont DVM PLUS 4 Europe Type H R Heating Operation ª V V V HDWLQ J ª V V V V V HDWLQ J J V V V V V V HDWLQ J V V V V V V V V V V HDWLQ J V V V HDWLQ J RZ WHPSHUDWXUH SUHVVXUH OLTXLG LJK WHPSHUDWXUH SUHVVXUH JDV LJK WHPSHUDWXUH SUHVVXUH OLTXLG RZ WHPSHUDWXUH SUHVVXUH JDV HDWLQ J 9 6 B B LQGG ...

Page 505: ...operation ⒶⒷ Ⓒ Cycle Operation Mode cont DVM PLUS 4 Europe Type H R Main Heating Operation ª V V V HDWLQ J V V V V V V HDWLQ J V V V V V V V HDWLQ J V V V V V V V V V ծ կ հ RROLQJ V V V HDWLQ J RZ WHPSHUDWXUH SUHVVXUH OLTXLG LJK WHPSHUDWXUH SUHVVXUH JDV LJK WHPSHUDWXUH SUHVVXUH OLTXLG RZ WHPSHUDWXUH SUHVVXUH JDV RROLQJ LJK WHPSHUDWXUH SUHVVXUH OLTXLG 9 6 B B LQGG ...

Page 506: ...he low pressure is 12 2kg cm g 4 If the low pressure goes below around 2kg cm g then immediately close the SVC valve for the gas and finish the pump down operation Finish the pump down operation press K2 button two more times or reset the operation by pressing the K3 button once more 9 3 3 When Two or More Outdoor Units are Installed 1 Close the gas valves of each sub unit 2 Press the K2 button of...

Page 507: ...rigerant container valve so that the refrigerant flows from the liquid pipe to the refrigerant container 6 Check the changes in the weight of the container using the scale Once the desired amount of refrigerant is filled up inside the container close the valves and then remove the Manifold gauge 7 The amount of refrigerant that can be contained inside the container is about 50 of the amount of ref...

Page 508: ...o Ltd Sep 2011 Printed in Korea Code No DB98 33425A 3 GSPN Global Service Partner Network Area Web Site North America http service samsungportal com Latin America http latin samsungportal com CIS http cis samsungportal com Europe http europe samsungportal com China http china samsungportal com Asia http asia samsungportal com Mideast Africa http mea samsungportal com 9 6 B BFR LQGG ...