Operating Instructions and Installation
3-7
Samsung Electronics
3-2-2(c) Connecting the Assembly Cable.
N1 L1
1
2
3
4
N
L
N1 L1
1
2
3
4
1
L1
N1
E
1
L1
N1
E
E
N
L
E
Indoor
unit
Outdoor unit
Circuit Breaker
(Main Power)
The indoor unit is powered from the outdoor unit via the assembly cable. If the outdoor unit is more than
five metres away from the indoor unit, the cable must first be extended to a maximum of 15 metres.
1. Extend the assembly cable if necessary.
2. Open the front grille by pulling on the tabs on the lower right and left sides of the indoor unit.
3. Remove the screw securing the connector cover.
4. Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals
N1, L1, 1, 2, 3.
• Each wire is labelled with the corresponding terminal number.
5. Firmly fix the ass’y cable with clamp wire holder.
6. Pass the other end of the cable through the 65mm hole in the wall.
7. Replace the connector cover, carefully tightening the screw.
8. Close the front grille.
9. For further details on how to plug the other end of the assembly cable into the outdoor unit, refer to
page 3-8.
<
✳✳
18
✳✳
>
N1 L1
1
2
3
4
N
L
N1 L1
1
2
3
4
Indoor
unit
Outdoor
unit
Circuit Breaker
(Main Power)
3
2
1
L1
N1
E
3
2
1
L1
N1
E
E
N
L
E
<
✳✳
24
✳✳
>
DB98-05464A(1)-1 4/18/02 8:01 PM Page 3-7
Summary of Contents for ASA24C5
Page 3: ...MEMO Samsung Electronics 1 2...
Page 9: ...MEMO Samsung Electronics 2 6...
Page 40: ...MEMO 5 13 Samsung Electronics...
Page 49: ...MEMO Samsung Electronics 6 9...
Page 53: ...Samsung Electronics 8 3 8 2 Main PCB 8 2 1 Outdoor Unit PE S1452R 00 SC18AC9 0...
Page 56: ...9 1 Samsung Electronics 9 Wiring Diagrams 9 1 Indoor Unit SC24AC5 6 ASA24C5 6 ME...
Page 57: ...Samsung Electronics 9 2 Wiring Diagrams SC18AC9 0 ASA18C9 0 ME...
Page 62: ...MEMO Samsung Electronics 10 7...
Page 64: ...ELECTRONICS Samsung Electronics Co Ltd Apr 2002 Printed in Korea Code No DB98 05464A 1...