E-
31
ENGLISH
Fixing the Installation Plate
30mm
(1
)
3
16
65mm
0
Pipe Hole
(2
)
9
16
(10)
252
(11)
275
(5
)
140
1
2
(3
)
90
5
8
(2
)
60
3
8
(1
)
30
3
16
410~730
16
~
1
8
28
3
4
()
Before fixing the installation plate to a wall or window frame, you
must determine the position of the 65mm( inch) hole through
which the cable, piping and hose pass to connect the indoor unit up
to the outdoor unit. When facing the air conditioner in position on
the wall, the piping and cable can be connected from the:
◆
Right
◆
Left
◆
Rear (right or left)
1
Determine the position of the pipe and drain hose hole using the right
figure and drill the hole with an inner diameter of 65mm( inch) so that it
slants slightly downwards.
2
If you are fixing the indoor unit to a...
Then follow Steps...
Wall
3.
Window frame
4 to 6.
3
Fix the installation plate to the wall in a manner appropriate to the weight
of the indoor unit.
➢
If you are mounting the plate on a concrete wall with anchor bolts, the
anchor bolts must not project by more than 20mm( inch).
4
Determine the positions of the wooden uprights to be attached to the
window frame.
5
Attach the wooden uprights to the window frame in a manner appropriate
to the weight of the indoor unit.
6
Using tapped screws, attach the installation plate to the wooden uprights,
as illustrated in the last figure opposite.
Installation plate
Unit : mm(inch)
Unit : mm(inch)
I
NSTALLING THE
I
NDOOR
U
NIT
2
9
16
3
4
2
9
16
Unit : mm(inch)
✴✴
07/09/12
✴✴
✴✴
18/24
✴✴
45mm/
(1
)
3
4
65mm
0
Pipe Hole
(2
)
9
16
Installation plate
Unit : mm(inch)
(10)
255
(12
)
325
3
4
(16
)
415
3
8
(20)
512
(2
)
60
3
8
(1
)
45
3
4
410~730
(16
)
~
1
8
28
3
4
Unit : mm(inch)
Unit : mm(inch)
Summary of Contents for AS12A5
Page 26: ...E 26 INSTALLATION MANUAL...