Samsung Electronics
34
Feature & Operation
6-2-4 Dry Operation Control
●
Operation pattern
●
Operation Specification
◆
1. ON/OFF Time by Dry Modes
1
1) Select a dry operation mode (
I
,
II
,
III
or
IV
) based on the room temperature.
1
"Room Temp. > Ts+4" = Dry
I
-Mode
1
"Room Temp. < Ts+1" = Dry
III
-Mode
1
Other than Dry
I
-Mode and
III
-Mode = Dry
II
-Mode
1
In Dry
III
-Mode, "Room Temp.
≤
Set Temp.-1" = Dry
IV
-Mode
◆
2. Compressor and Indoor Fan Operation Cycle
(
I
-Mode)
Room Temp.(˚C)
✳
Ts=Remote Control Set Temp.
(
II
-Mode)
(
III
-Mode)
(
IV
-Mode)
Ts+4
Ts+3
Ts+2
Ts+2
Ts
Ts-1
Compressor
Operation
Indoor Fan
Operation
Initial setup
6 min.
Operation
Judge the next dry mode after 3 min. from Compressor ON.
Compressor &
Operation Cycle(Min.)
Outdoor Fan
I
-Mode
II
-Mode
III
-Mode
IV
-Mode
ON Time
6 Min.
5 Min.
4 Min.
COMPRESSOR=OFF
OFF Time
4 Min.
5 Min.
6 Min.
ON
OFF
ON
LL
1st CYCLE
3 min
3 min
3 min
2nd CYCLE
OFF
ON
OFF