Troubleshooting
Samsung Electronics
12-14
12-2-12 O.C.(Over Current) error
1. Checklist :
1) Is the Shunt resistance value correct?
2) Is the condition of surrounding temperature abnormal overload?
3) Is there any problem as like the temperature sensor separation or measurement value error?
4) Is the interphase resistance of compressor normal?
2. Troubleshooting procedure
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Restart after power off.
No
Is the O.C.(Over Current) error occurred?
Terminate the service.
No
Is the Shunt resistance value normal?
Exchange the PCB.
No
Is the interphase resistance value
of compressor(u
↔
v, v
↔
w, w
↔
u) normal?
Exchange the Compressor.
No
No
Yes
Is the compressor body and
interphase resistance insulated?
Exchange the Compressor.
No
Is the connection cable for
the compressor and power terminal normal?
Exchange the PCB.
Correct the cable connection.
No
Is the position of temperature sensor
and the sensing value normal?
Correct the sensor position or
exchange the sensor.
No
Is the condition of
indoor/outdoor temperature normal load?
Restart after returning
to the normal load.
Is the O.C. error occurred again?
Terminate
the service.
24437A(1)_1 1/16/05 9:58 PM Page 12-14
Summary of Contents for AS09BPA
Page 30: ...MEMO Samsung Electronics 5 4 ...
Page 34: ...MEMO Samsung Electronics 5 8 ...
Page 35: ...Samsung Electronics 5 9 5 4 Ass y Control Out AS09BPAX DB93 03450B AS12BPAX DB93 03450A ...
Page 80: ...MEMO 12 23 Samsung Electronics ...
Page 84: ...Block Diagram 13 4 Samsung Electronics DC_LINK CAP B D DIODE IPM OUTDOOR FAN SMPS IGBT ...