8 . C O M P U L S O RY O P E R ATION :
For operating the air conditioner without
the remote contro l l e r.
* A U TO : The operating is the same func-
tion that A U TO MODE in the remote con-
t ro l l e r.
9 .
SWING : BLADE-H is rotated vertically by
the stepping motor.
*Memory louver : When ON/OFF button is
p ressed at stop state, the BLADE-H re t u r n s
to its original location which is operating
state before stop
*Swing auto : The BLADE-H can ro t a t e
within about 10,500 in the original position
set by the SWING SET button.
*Swing Set : Press the button under the
remote control is displayed on LCD the ,
and the blades move up and down, about 43°.
If the one more time press the button, bla-
tles location is stop.
1 0 . Quick OFF TIMER: OFF timer (quick timer)
allows reservation or cancel the timer on
and timer off quickly
When OFF timer button is pressed at oper-
ating state, LCD displays the polling state
s e q u e n t i a l l y.
The LCD also displays the time re m a i n i n g .
11 . 24-Hour ON/OFF Real Setting Ti m e r. : The
air conditioner is turned ON at a specified
time using .
OFF TIMER : The air Conditioner is turned
OFF at a specified time using .
*ON TIMER : Only timer LED lights on.
*OFF TIMER : Both timer and operation
LED lights on.
*3 minutes delay timer.
1 4 . SELF Diagnosis
1 5 . TIME SHORTENING : If the "Time short"
connector pin is shorted on the main P. C. B,
the compressor's three minutes delay func-
tion is cancelled, and each operation time is
shortened to one fiftieth of its original time.
1 6 . BUZZER SOUND : Whenever the ON/OFF
button is pressed or whenever change
occurs to the condition which is set up or
select, the compulsory operation mode,
buzzer is sounded "beep"
Operating Instructions and Installation
ON TIMER
OFF TIMER
I n t e r ruption of electric power and Power on.
Check Point
LED DISPLAY
o p e r-
a t i o n T I M E R FA N
L E D
:
b l i n k i n g
: LED off
Tu r b o
Abnormal condition of the room sensor.
Indoor unit fan motor lock.
Abnormal condition of the indoor unit's heat exchanger sensor.
Summary of Contents for AS070VE
Page 2: ... Samsung Electronics Co Ltd JAN 1998 Printed in Korea Code No DB81 10123A 1 ...
Page 4: ...1 2 Samsung Electronics MEMO ...
Page 14: ...2 10 Samsung Electronics MEMO ...
Page 28: ...3 14 Samsung Electronics MEMO ...
Page 34: ...4 6 Samsung Electronics MEMO ...
Page 44: ...Samsung Electronics 6 1 6 Exploded Views and Parts List 6 1 Indoor Unit ...
Page 46: ...Samsung Electronics 6 3 6 2 Outdoor Unit 25 1 25 26 2 26 1 ...
Page 50: ...6 7 Samsung Electronics MEMO ...
Page 52: ...Samsung Electronics 8 1 8 PCB Diagrams 8 1 a Main PCB 7000Btu DB93 10484A ...
Page 54: ...Samsung Electronics 8 3 8 1 b Main PCB 9000Btu DB93 10486A 12000Btu DB93 10482A ...
Page 57: ...Samsung Electronics 9 1 9 Wiring Diagrams 9 1 Indoor Unit ...
Page 59: ...Samsung Electronics 9 3 MEMO ...
Page 60: ...Samsung Electronics 9 4 MEMO ...
Page 61: ...10 1 10 Schematic Diagrams 10 1 Indoor Unit Samsung Electronics ...
Page 62: ...Samsung Electronics 10 2 10 2 Remote Control ...