8-
6
Samsung Electronics
8-
Wire connecting the indoor unit terminal blocks
1. Terminal press of Ring terminal shall be set facing up before connecting wire.
Is inverted
Terminalhasbeencut.
2. There shall be no empty space between Ring terminal and Screw after Clamp.
If not, there exists a possibility
ich can be caused by electric heat in the connecting part.
, : Good
Bad : Ring terminal is connected reversely
Bad : Not clamped Screw
Bad : In the gap between Ring terminal & Screw
Bad : Unused Ring Terminal