Samsung Electronics
10-29
10-2-24 No power outdoor (Initial Diagnosis) (Not displayed)
1. Checklist :
1) Is input power normal?
2) Is AC power linked correctly? (L,N,E)
3) Is mis-wiring between communication wire and Power wire?
4) Is mis-wiring between Main PBA and SMPS PBA wire?
5) Is input voltage of SMPS AC in Main PBA (CN150) normal?
6) Is the voltage of SMPS DC in Main PBA (CN151,CN152) normal?
2. Troubleshooting procedure
Unplug the power cord
Restart after power o .
Check SMPS wire connection
Is the power cable from
terminal block to PBA is correct?L :CN002, N:CN001,
EARTH:CN003
Is the power normal?
Check the fuse open or not? (F001)
Is AC power is normal for SMPS?
CN150 : 220Vac~240Vac
NO
NO
NO
NO
Reconnect the power wire correctly.
Check the power source.
Exchange the Main PBA
Exchange the Main PBA
YES
YES
YES
YES
MODEL
ALL
YES
Exchange the PBA
Summary of Contents for AR18NSFHBWKNEU
Page 11: ......
Page 12: ......
Page 17: ......
Page 24: ...4 10 s c i n o r t c e l E g n u s m a S 2 2 ...
Page 41: ...DB68 05092A 4 ...
Page 42: ...7 2 _18K DB68 06674A 1 ...
Page 43: ...7 3 7 2 Outdoor Unit_24K DB68 06675A DB68 06675A 00 ...
Page 45: ...S a m s u n g C o n f i d e n t i a l S a m s u n g ...
Page 46: ...8 3 8 3 Refrigerating Cycle Diagram ...
Page 53: ...9 1 2 9 2 AR18NSFPEWQXEU AR24NSFPEWQXEU AR18NSFHBWKXEU AR24NSFHBWKXEU Outdoor Unit ...
Page 90: ...10 3 10 36 ...
Page 91: ......
Page 92: ......
Page 95: ...12 3 12 3 ...
Page 96: ...12 4 12 4 ...
Page 97: ...12 5 ...
Page 98: ...12 6 ...
Page 100: ...12 5 2 12 8 ...
Page 101: ...12 6 12 9 12 6 1 12 6 2 ...
Page 102: ...12 7 12 7 1 12 10 ...
Page 103: ...12 7 2 12 11 ...
Page 105: ......