Deciding the Installation Place
You should observe the following restrictions when you decide the installation place.
General
Do NOT install the air conditioner under the following conditions;
Combustible gases
Saline air
Machine oil
Sulfide gas
Special environmental conditions
If you have no alternative place to install it, first consult your dealer or a qualified person.
Indoor Unit
There must be no obstacles near the air inlet and outlet.
Install the indoor unit on a surface that can support its weight.
Choose a place where you can easily connect the pipes and cables to the outdoor unit.
The recommended length of the pipes and cables is 24.7ft(7.5m). The maximum length is 98.4ft(30m).
Leave sufficient space below the indoor unit to remove the filters easily.
Maintain sufficient space around the indoor unit as seen in the picture on page 5.
Make sure that the water dripping from the drain hose runs off correctly and safely.
Install the indoor unit higher than 8.2ft(2.5m) from the ground.
Outdoor Unit
NEVER place the outdoor unit on its side or upside down. The compressor lubricating oil may run into the circuit and
damage the outdoor unit seriously.
Choose a dry and sunny place avoiding direct sunlight or strong winds.
Do not obstruct the passage.
Avoid a place that may disturb your neighbor. A noise may occur from the outdoor unit and the discharged air may
run into the neighborhood.
Choose a place where you can easily connect the pipes and cables to the indoor unit. The recommended length of
the pipes and cables is 24.7ft(7.5m). The maximum length is 98.4ft(30m).
Install the outdoor unit on a flat and stable surface. Otherwise it may slant and make some noise and vibration.
Install the outdoor unit on a hard and even place that can support its weight.
Place the outdoor unit so as to let the discharged air out properly.
Maintain sufficient space around the outdoor unit as seen in the picture on page 5.
When you install the outdoor unit at a height, you should firmly fix it in its place. The maximum height is 49.4ft(15m).
Make sure that the water dripping from the drain hose runs off correctly and safely.
The air conditioner must be installed according to the national electrical rules.
Max input power & current is measured according to IEC standard and input power & current is
measured according to ISO standard.
CAUTION
P
REPARING
THE
I
NSTALLATION