Installing and Connecting the Drain Hose of the Indoor Unit
When installing the drain hose for the indoor unit, you should check if condensate draining is adequate.
When you pass the drain hose through the 65mm hole drilled in the wall, check the following.
To install the drain hose, do the following.
1
If necessary, connect the 6.6ft(2m) extension drain hose to the drain hose.
2
If you use the extension drain hose, insulate the inside of the extension drain
hose with a shield.
3
Fit the drain hose into 1 of 2 drain hose holes, and then fix the end of the
drain hose with a clamp tightly.
If you don’t use the other drain hose hole, block it with a rubber stopper.
4
Pass the drain hose under the refrigerant pipe keeping the drain hose tight.
5
Pass the drain hose through the hole in the wall. Check if it slants downwards
as seen in the picture.
The hose will be fixed permanently into position after finishing the
installation and the gas leak test; refer to page 12 for further details.
Installing and Connecting the Drain Hose of the Outdoor Unit
While heating, ice may accumulate. During the process of defrosting, you
should check if condensate draining is adequate.
For the adequate draining, do the following.
1
Insert the drain plug into the drain hole on the underside of the outdoor
unit.
2
Connect the drain hose to the drain plug.
3
Ensure that condensate draining is adequate.
Shield
Drain hose
Extension drain hose
Drain hole
The hose must
NOT slant upwards.
The end of the drain
hose must NOT be
placed under water.
Do NOT bend the hose
in different directions.
Keep a clearance of
at least 2inch(50mm)
between the end
of the hose and the
ground.
2inch
(50mm)
less
Do NOT place the end
of the drain hose in a
hollow.
Ditch