Samsung Electronics
5-2
5-2 Fault Diagnosis by Symptom
5-2-1 No Power (completely dead)-Initial diagnosis
1) Checklist :
(1) Is input voltage normal? (the rating voltage
±
10% range)
(2) Is AC power linked corre c t l y ?
(3) Are connections between primary side, secondary side of the power transformer and PCB good.
(4) Is output voltage of DC regulator IC KA7812 (IC01) normal? (11 V D C - 1 2 . 5 V D C )
(5) Is output voltage of DC regulator IC KA7805 (IC02) normal? (4.5VDC-5.5VDC)
2 )
Troubleshooting pro c e d u re
Replace PCB
display
Is DC voltage of PCB
display normal?
Remove power cord and plug in again
in approx. 5 seconds
Is operation lamp blinking?
Does operation start when
run/stop button on the remote
controller unit pushed?
Is transmission display of the remote
controller unit blinking?
Is "beep"sound heard from the main
unit?
Is DC voltage of the PCB module
normal?
Are voltages of #57 (compressor),
#48 (4 way valve) and #58 (outdoor fan)
of the micom normal? (5VDC)
Is voltage of #1 (indoor fan) of the
micom normal?
Is voltage at #32 terminal of the Micom normal?
; 0VDC
Is voltage at #64 terminal of the Micom normal?
; 5VDC
Is the input rating
±
10%
range applied to the
primary side of the power
transformer?
•Check linkage between
power cord and
terminal tap
•Check fuse
Is 14~18VAC appear in
the secondary side of the
power transformer?
Replace power
transformer
YES
NO
YES
NO
YES
YES
YES
NO
YES
YES
YES
DC5V
10ms
10ms
100ns
NO
NO
OK
YES
YES
YES
YES
NO
NO
YES
Normal
Refer to remote control
unit fault diagnosis
Replace PCB
module.
Is output voltage of ICO2 normal?(DC5V)
Check connections
compressor 4-way
valve, outdoor fan and
indoor fan.
Are voltages at RY71(Compressor)
RY73 (4 way vale) and RY 72 (Outdoor fan)
normal? (DC12V)
Is voltage at SS71(indoor fan)
Replace
RY71, RY73,
RY72 and
SS71
NO
NO
NO
Is voltage output terminal of
D101~D105(IN4007) normal?
Replace ICO2
Check PCB pattern .
Replace main PCB.
Replace IN4007
Replace
micom
Is voltage at #25 terminal of the micom
normal?
Are voltage at #30 and #31 of the
micom normal?
NO
NO
NO
YES
NO
NO
NO
YES
OK
Is operation normal?
Replace resonator (X501)
Summary of Contents for AQT24A1QE/B
Page 2: ...Samsung Electronics Co Ltd DEC 1998 Printed in Korea Code No DB81 00029A 1...
Page 4: ...1 2 Samsung Electronics MEMO...
Page 9: ...2 5 Samsung Electronics 2 4 Pressure Graph 24K BTU 18K BTU...
Page 10: ...2 6 Samsung Electronics MEMO...
Page 28: ...4 5 Samsung Electronics MEMO...
Page 38: ...Samsung Electronics 6 1 6 Exploded Views and Parts List 6 1 Indoor Unit...
Page 46: ...6 9 Samsung Electronics MEMO...
Page 48: ...Samsung Electronics 8 1 8 PCB Diagrams 8 1 Main PCB B B B...
Page 51: ...Samsung Electronics 9 1 9 Wiring Diagrams 9 1 Indoor Unit...
Page 54: ...Samsung Electronics 10 1 10 Schematic Diagrams 10 1 Indoor Unit PNA4612MOOXD...