208/230V
System
Breaker
Separate all Power &
Communications Wiring by 2”
Indoor Unit
(Ground)
Outdoor
Unit
F2
F1
G
L1
L2
F2
F1
G
L1
L2
POWER VOLTAGE:
Power Voltage:
208/230V - 1 Ph - 60 Hz
Control Voltage:
DDC Fuzzy Logic
Main Breaker Size:
30 A
CHARGING:
Unit is charged for:
25 ft. (Factory Charge 88.1oz. R410A)
Additional Charge of R410A:
0.43 oz./ft. over 25 ft.
CHARGE FOR LINE RUN LENGTHS:
Length:
25
35
45
55
65
75
85
95
98
Added Charge (oz.):
0
4.3
8.6 12.9 17.2 21.5 25.8 30.1 32.25
INTERCONNECTING WIRING:
Gauge:
14 AWG Power & 16 AWG Shielded Communication
Number of Interconnecting Wires: 3x14 AWG Power & 2x16 AWG Control = 5 Total
LINE SIZES:
“Liquid” (expanded gas) line:
1/4”
Suction:
5/8”
BOTH LINES MUST BE INSULATED SEPARATELY
Samsung MAX 36,000 BTU Mini-Split
Indoor Unit: #700558 (AQN36VFUAGM)
Outdoor Unit: #700560 (AQX36VFUAGM)
INTERCONNECT LENGTH:
Maximum/Minimum Length:
164 feet / 10 feet
Vertical Lift:
98 feet (Trap required at 26 ft.)
Note: Condenser can be above or below evaporator