7-4
Samsung Electronics
7-4 Refrigerating Cycle Block Diagram
Heat
exchanger
(Evaporator)
Gas side
3-way valve
3-way valve
Liquid side
Cooling
Gas leak check point
Heat
exchanger
(Condenser)
Heating
Capillary tube
Check valve
Compressor
4-way valve
Capillary tube
Refrigerating cycle temperature and pressure
*
Amount of refilling per extension length of 1m;
When extending the pipe length by more than 5m, 40g of R-22 refrigerant should be refilled per
extension length of 1m.
Allowavle pipe length:Maximum 15m
Allowable pipe drop distance:Maximum 10m
Operating Condition
STD Pressure
(kg/cm
2
G)
(GAS SIDE)
Piping Temp.
Use Temp. Condition (°C)
T1
T2
Indoor
Outdoor
DB
27
32
21
20
27
20
40~45
50~55
30~35
32~36
36~40
28~32
4.5~5.5
6.5~7.5
3~4
18.5~20.5
-
-
Cooling
Heating
Standard
Max over load
Low temp
Standard
Max over load
Deice
9~12
14~18
1~4
65~75
70~80
40~45
19
23
16
-
-
-
35
43
21
7
21
2
24
26
16
6
16
1
WB
WB
DB
INDOOR UNIT
OUTDOOR UNIT
Summary of Contents for APH180HD
Page 4: ...2 2 Samsung Electronics 2 2 Dimensions Indoor Unit Outdoor Unit unit mm 330...
Page 31: ...Samsung Electronics 6 7 6 2 Outdoor unit...
Page 38: ...Samsung Electronics 8 1 8 PCB Diagrams 8 1 Ass y Main PCB...
Page 42: ...Samsung Electronics 8 5 8 2 Ass y PANEL PCB...
Page 45: ...Samsung Electronics 9 1 9 Wiring Diagrams 9 1 Indoor Unit 9 1 1...
Page 46: ...Samsung Electronics 9 2 9 1 2 Wiring Diagrams...
Page 47: ...Samsung Electronics 9 3 Wiring Diagrams 9 1 3...
Page 49: ...10 1 10 Schematic Diagrams 10 1 Indoor Unit Samsung Electronics...
Page 50: ...Samsung Electronics 10 2 10 2...
Page 51: ...Samsung Electronics 10 3 10 3...