38_ installation part
When using the rubber leg
When using the anchor bolt
INSTALLATION METhOd
Outdoor Unit
Anchor bolt fixing dimensions
B
A
660mm
340mm
Outdoor unit
leg
Rubber leg
1. Fix the unit on a flat, rigid floor using the anchor bolt.
(Anchor bolt : M10 x 4 points - separately purchased)
1. Put the rubber leg to the outdoor unit leg.
Installation Procedures
2. Open the front panel and separate it from the unit.
- Be careful of the power lines connected to control panel when removing.
3. Bend the connection pipe to an appropriate length using the spring bender depending upon the installation
place.
- Allowable pipe length : Maximum 30m
- Allowable pipe drop distance : Maximum 20m
- Make no more than ten bending points on the pipe
※
When the pipe length is in excess of the standard pipe length of 5m, add the refrigerant (R22) of 20g for
each additional 1m.
1. The piping of this unit can be connected to the right, left, and rear side.
When you hit the area for piping connection slightly with a hammer, a hole is made.
Holes for piping
connection (4 points)
When the hole on the wall is higher
than the hole for piping connection.
When the hole on the wall is lower
than the hole for piping connection.
Piping
Drain hose
Protective
piping cover
If the pipe is lengthened, the performance of the unit is degraded, and the service life is shortened.
Therefore, the pipe length should be as short as possible (less than 15m).
Piping
Drain
hose
Protective
piping
cover