Samsung AP36M0A Series User & Installation Manual Download Page 1

Air Conditioner

user & installation manual

imagine

 the possibilities

Thank you for purchasing this Samsung product. 
To receive more complete service, please 
register your product at

www.samsung.com/register

AP36M0A Series

DB98-33839A(1) 

E

AP36M0A_IBIM_E_DB98-33839A-1.indd   49

2011-06-10   오후 1:38:13

Summary of Contents for AP36M0A Series

Page 1: ...ine the possibilities Thank you for purchasing this Samsung product To receive more complete service please register your product at www samsung com register AP36M0A Series DB98 33839A 1 E AP36M0A_IBIM_E_DB98 33839A 1 indd 49 2011 06 10 오후 1 38 13 ...

Page 2: ...on which makes you cool fast for 30 minutes and Long function which makes the cool air goes to much further place Look for Everywhere The elegant and harmonious design gives priority to the esthetics of your space and complements any of your existing interior décor With its soft color and latest design the new air conditioner adds class to any room Enjoy what your air conditioner offers both funct...

Page 3: ...line at www samsung com Important safety symbols and precautions WARNING Hazards or unsafe practices that may result in severe personal injury or death CAUTION Hazards or unsafe practices that may result in minor personal injury or property damage CAUTION To reduce the risk of fire explosion electric shock or personal injury when using your air conditioner follow these basic safety precautions Do ...

Page 4: ...of fire or electric shock Install an exclusive circuit breaker and short circuit breaker for the air conditioner Potential risk of electric shock or fire Do not insert anything such as fingers or branches into the air conditioner vents while the air conditioner is running Keep the children away from the air conditioner to prevent them from putting their finger on the air conditioner Potential risk...

Page 5: ... appropriate measures to prevent the allowable concentration from being exceeded If the refrigerant leaks and cause the concentration limit to be exceeded hazards due to lack of oxygen in the room may result If the indoor unit gets wet turn the power off immediately and call your nearest contact center Potential risk of fire or electric shock Always make sure that the power supply is compliant wit...

Page 6: ...ck or fire if repairs or installations are attempted by a non qualified service technician Do not spray flammable gases such as insecticide near the air conditioner Potential risk of electric shock fire or unit malfunction Do not open the front panel during operation Potential risk of electric shock or unit malfunction Cool air should not flow directly towards people pets and plants It is harmful ...

Page 7: ...erial and used batteries of the remote controller optional must be disposed of in accordance with the national standards The refrigerant used in the air conditioner must be treated as chemical waste Dispose the refrigerant following national standards Have a qualified service technician install the air conditioner and perform a trial operation Firmly connect the drain hose to the air conditioner f...

Page 8: ...t has been designed the indoor unit is not suitable to be installed in areas used for laundry Ensure the off on and protection switches are properly installed Do not use the air conditioner if damaged If problems occur immediately stop operation and disconnect the plug from the power supply If the air conditioner will not be used for an extended period of time for example over several months unplu...

Page 9: ...ng the filter 27 Air filter 28 Maintaining your air conditioner 28 Periodical checks 29 Internal protections via the unit control system 29 Storing the remote controller APPENDIX 30 30 Troubleshooting 31 Operation ranges contents viewing your air conditioner 10 10 Checking the indoor unit and display 10 Main parts 11 Control panel 12 Checking the remote controller 13 Remote controller display 13 U...

Page 10: ...d check the indoor unit to make sure it is not damaged Main parts Your air conditioner may slightly look different from illustration shown above depending on your model Air flow blade right left orientation Heat exchanger cleaning section Air flow blade up down orientation Control panel Air intake Air filter To open the panel Hold the upper part of the panel then pull it slightly forward Don t ope...

Page 11: ...Right button Fans speed adjustment button Temperature adjustment buttons Power button Timer indicator Turbo button Outdoor unit operation indicator Turbo indicator Air swing Left Right indicator Air swing Up Down indicator Long function indicator Lock indicator Temperature setting Operation indicators Mode selection button Heater Purity Heat and Defrost function is not supported by this model AP36...

Page 12: ...ions Air swing Up Down Activate Deactivate air flow blade movement automatically up and down On Timer Set the On Timer on Off Timer Set the Off Timer on This button is not functional viewing your air conditioner CHECKING THE Remote controller You can activate the air conditioner by pointing the remote controller away from it When using the remote controller always point it directly at the air cond...

Page 13: ...n you properly press the button on the remote controller you will hear ring sound from the indoor unit The signal may not be received well of electronic lighting style fluorescent lamps such as inverter fluorescent lamps are in the same space If other electrical products operate by the remote controller call your nearest contact center On Off timer indicator Operation mode indicator When the Heat ...

Page 14: ... mode Press the Mode button on the remote controller until Auto mode and Auto fan speed indicator appear on the remote controller display The air conditioner will automatically set the operation mode to Cool depends on the room temperature Each time you press the Mode button the mode will change in order of Auto Cool Dry and Fan 3 Adjust the temperature if you need to increase or decrease the room...

Page 15: ... the temperature by 1 C 4 Set the fan speed Press the Fan or button on the remote controller to set the desired fan speed If room temperature reaches desired value the air conditioner will shut off cooling for a while and just the fan runs Each time you press the Fan or button fan speed will change in order of Auto Low Medium and High While you are using the remote controller make sure correct ind...

Page 16: ... operates in Dry mode and automatically adjust the fan speed to Auto Each time you press the Mode button the mode will change in order of Auto Cool Dry and Fan 3 Set the temperature Press the Temp or button on the remote controller to increase or decrease the desired temperature You can set the desired temperature between the range of 18 C 30 C You can increase decrease the temperature by 1 C Whil...

Page 17: ... mode and circulate the indoor air Each time you press the Mode button the mode will change in order of Auto Cool Dry and Fan 3 Set the fan speed Press the Fan or button on the remote controller to set the desired fan speed Each time you press the Fan or button fan speed will change in order of Low Medium and High While you are using the remote controller make sure correct indicator which matches ...

Page 18: ... if Dry Fan mode is most recent mode used Turbo function is only available in Cool Auto mode If Turbo function is selected in Dry Fan mode operation mode changes to Auto You cannot use Turbo and Long function at the same time To deactivate Turbo function 1 Press the Turbo Long button on the remote controller twice while Turbo function is on The air conditioner operates in last used mode or in Auto...

Page 19: ...flow blades face upward and vertical air flow direction control is not possible You cannot use Turbo and Long function at the same time To deactivate Long function 1 Press the Turbo Long button on the remote controller while Long function is on The air conditioner operates in last used mode or in Auto mode if Dry Fan mode is most recent mode used While you are using the remote controller make sure...

Page 20: ...your desired position Vertical air flow 1 Press the Air swing Up Down button on the remote controller The air flow blades move up and down To keep the air flow direction in a constant position press the Air swing Up Down button on the remote controller again AP36M0A_IBIM_E_DB98 33839A 1 indd 20 2011 06 10 오후 1 37 46 ...

Page 21: ...roller The air flow blades move right and left To keep the air flow direction in a constant position press the Air swing Left Right button on the remote controller again When using the Long function vertical air flow direction control is not possible AP36M0A_IBIM_E_DB98 33839A 1 indd 21 2011 06 10 오후 1 37 48 ...

Page 22: ... will show the hour s you have set for 3 seconds and set desired temperature will display The air conditioner will operate automatically at set time and then On timer indicator stops blinking and stays on If On timer is not set within 10 seconds the air conditioner will end setting 4 Set the operation mode Press the Mode button on the remote controller until the desired mode appears on the remote ...

Page 23: ...emote controller display will show the hour s you have set for 3 seconds and set desired temperature will display The air conditioner will operate automatically at set time and then Off timer indicator stops blinking and stays on If Off timer is not set within 10 seconds the air conditioner will end setting When the Off Timer setting is done you can press the Off Timer button again to change the p...

Page 24: ...set time of the On Timer is 3 hours and the Off Timer is 5 hours the air conditioner will turn on after 3 hours from the moment you have set the timer Your air conditioner will remain on for 2 hours and then turn off automatically Preset time of On Timer is longer than Off Timer The air conditioner will turn off and then on automatically Set up should be done while the air conditioner is operating...

Page 25: ... Press the or button to adjust the temperature You can set the desired temperature between the range of 18 C 30 C You can increase decrease the temperature by 1 C 3 Press the Fan Speed button to adjust the fan speed Each time you press the Fan Speed button the fan speed will change in order of Auto Low Medium and High 4 Press the Mode button to select operation mode You can select operation mode y...

Page 26: ...bo mode The unit will operate in Turbo mode for 30 minutes LOCKING THE CONTROL PANEL You can lock the control panel on the indoor unit to prevent the children from playing with the air conditioner When the air conditioner is on or off 1 Press the and buttons for 3 seconds You will hear ring and the Lock indicator will appear on the indoor unit display Once Lock is set you cannot control the air co...

Page 27: ...ing 1 Open the panel and pull out the air filter after removing the tape that holds the air filter Pull out the air filter in the direction of the arrow as shown in the below figure 2 Clean the air filter with a vacuum cleaner or in running water If dust is too heavy use warm water mixed with detergent Do not scrub the filter too hard since it may get damaged 3 Dry the air filter in a ventilated a...

Page 28: ...anger 2 Clean the condensate drain pipe 2 Replace the remote controller batteries 1 Outdoor unit Clean the heat exchanger on the outside of the unit 2 Clean the heat exchanger on the inside of the unit 2 Clean the electric components with jets of air 2 Verify that all the electric components are firmly tightened 2 Clean the fan 2 Verify that all the fan assembly is firmly tightened 2 Clean the con...

Page 29: ... Protect compressor The air conditioner does not start operating immediately to protect the compressor of the outdoor unit after it has been started Storing the remote controller When you do not use the remote controller for a long time remove the batteries and store the remote controller in the remote controller holder AP36M0A_IBIM_E_DB98 33839A 1 indd 29 2011 06 10 오후 1 38 01 ...

Page 30: ... for the product protection The fan speed does not change Check if you selected Auto or Dry mode The air conditioner automatically adjusts the fan speed to Auto in Auto Dry mode Timer function does not set Check if you press the Set button on the remote controller after you have set the time Odors permeate in the room during operation Check if the appliance is running in a smoky area or if there i...

Page 31: ...OOR COOLING 18 C to 32 C 21 C to 54 C 80 or less Condensation may occur on the indoor unit with risk to have either water blow off or drops on the floor DRYING 18 C to 32 C 21 C to 54 C Condensation may occur on the indoor unit with risk to have either water blow off or drops on the floor If the cooling operation is used at over 32 C indoor temperature it does not cool at its full capacity AP36M0A...

Page 32: ...units if damaged If problems occur switch the unit off and disconnect it from the power supply In order to prevent electric shocks fires or injuries always stop the unit disable the protection switch and contact SAMSUNG s technical support if the unit produces smoke if the power cable is hot or damaged or if the unit is very noisy Always remember to inspect the unit electric connections refrigeran...

Page 33: ...ided in the wiring diagram included in the manual Always verify that electric connections cable entry section of leads protections are compliant with the electric specifications and with the instructions provided in the wiring scheme Always verify that all connections comply with the standards applicable to the installation of air conditioners Make sure that you earth the cables Do not connect the...

Page 34: ...ng bracket for indoor unit 2 Indoor Unit 2 Remote controller 1 3 Remote controller holder 1 4 M4 X L12 screws 4 5 M4 X L14 screws 4 6 Batteries for remote controller 2 7 Protective piping cover 1 8 Insulation for piping 1 9 Insulation for drain hose 1 10 User and Installation manual 1 AP36M0A_IBIM_E_DB98 33839A 1 indd 34 2011 06 10 오후 1 38 02 ...

Page 35: ... where strong wind does not head against the air outlet of the outdoor unit If a strong wind heads directly against the air outlet at the time of cool operation a safety device can be operated Do not install the outdoor unit at an unstable place such as outer wall of an apartment or building The outdoor unit may fall down causing severe personal or property damage or loss Install the unit at a pla...

Page 36: ...ge 207V 253V Min size of electric wires from to the indoor outdoor units 1mm2 You must compress the solderless ring to the cable and then connect it to the main power terminal Solderless ring selection Thickness of cable mm2 B mm d2 mm 2 5 Less than 9 5 More than 4 5 4 Less than 9 5 More than 4 5 Silver solder TheindoorunitispoweredbytheoutdoorunitbymeansofaH07RN Fconnectioncable oramorepowermodel...

Page 37: ... Make sure that the clamping force of the screw on the terminal is tightened firmly within the range of rated tightening torque The appliance shall be installed in accordance with national wiring regulations for installation SASO 2007 2002 Disconnection means must be incorporated in the fixed wiring in accordance with the wiring rules Connecting the power terminal Connect the cables to the termina...

Page 38: ...op distance Maximum 20m Make no more than ten bending points on the pipe When the pipe length is in excess of the standard pipe length of 5m add the refrigerant R22 of 20g for each additional 1m 1 The piping of this unit can be connected to the right left and rear side When you hit the area for piping connection slightly with a hammer a hole is made Holes for piping connection 4 points When the ho...

Page 39: ...late the pipe with appropriate insulation material 6 Insert the extension drain hose to the drain connection port tightly then fix them with a cable tie or a tape to prevent any water leakage refer to page 42 7 After completion of the installation check the connecting area for any gas leakage 8 Wind a finish tape when the wiring of the refrigerant pipe the unit and the drain piping are completed 9...

Page 40: ...ipe 3 Insert the flare nut into the pipe and then perform the flare processing A D Outer Diameter D A mm ø 9 52mm 1 8 ø 15 88mm 2 2 Inclined Damaged surface Cracked Uneven thickness When installing make sure there is no leakage When recovering the refrigerant ground the compressor first before removing the connection pipe If the refrigerant pipe is not properly connected and the compressor works w...

Page 41: ...ending Tightening of Connection Parts Align the pipes to be connected and tighten the flare nuts first manually and then with a torque wrench applying the following torque Outer Diameter Torque kgf cm ø 9 52mm 250 280 ø 15 88mm 440 480 You can avoid of gas leakage by applying refrigerant oil on the flare connection part Flareconnectionpart Pipe Nut Drilling a Hole in theWall Drill a hole of 60mm i...

Page 42: ...ny water leakage If there is any foreign substance in the drain plate it may clog the drain pipe Therefore be sure to remove the foreign substance inside after installation Do not extend the drain hose Insulated drain hose Extension drain hose Insulationfor extensiondrain hose Fixing the Indoor Unit If the indoor unit is installed on unstable place it may shake or fall down To prevent these accide...

Page 43: ... the valve of the low pressure side of manifold gauge clockwise Turn off the vacuum pump Make sure that pressure gauge show 0 1MPa 76cmHg after about 10 minutes This procedure is very important in order to avoid gas leak Remove the hose of the low pressure side of manifold gauge 5 Set valve cork of both liquid side and gas side of packed valve to the open position 6 Mount the cap and the needle va...

Page 44: ...kg cm2 G outside temperature 35 C Open the tank and refill the refrigerant until arriving at the proper pressure Refill the refrigerant slowly checking the pressure Stop operation Close the gas pipe side valve and loosen the pressure gauge connected Then open the gas pipe side valve again Tighten the cap of each valve using a specified tool OUTDOOR UNIT Gas pipe side Liquid pipe side Always use R2...

Page 45: ...leakage 2 Is the drain hose properly connected 3 Is the insulation of the piping in good condition 4 Is grounding properly made Outdoor connection area More than 30cm 30mm Pipe insulator Over 7mm foamed polyethylene or EPDM foam Pipie connection part insulator Over 5mm foamed polyethylene Indoor connection area AP36M0A_IBIM_E_DB98 33839A 1 indd 45 2011 06 10 오후 1 38 11 ...

Page 46: ... properly connected 1 Turn on the air conditioner and select Cool mode Test is only available in cooling operation Check if the cool air comes out from the indoor unit Check if the fan of outdoor unit rotates 2 If the units don t work as above check if the indoor outdoor unit s connection wires are properly connected The connection wires should be properly connected to the correct terminal number ...

Page 47: ...lready Unit mm 120 60 20 20 20 180 Power cable provided by us 20 Wire tube power cable After peeling off the tube wire you must insert a contraction tube 2 Insert both sides of core wire of the power cable into the connection sleeve Connection sleeve Comp dim Compress it 4 times 5mm 3 Using a compressor compress the two points and flip it over and compress another two points in the same location T...

Page 48: ...m KUWAIT 183 2255 www samsung com BAHRAIN 8000 4726 www samsung com EGYPT 08000 726786 www samsung com JORDAN 800 22273 www samsung com MOROCCO 080 100 2255 www samsung com SAUDI ARABIA 9200 21230 www samsung com TURKEY 444 77 11 www samsung com U A E 800 SAMSUNG 726 7864 www samsung com AP36M0A_IBIM_E_DB98 33839A 1 indd 48 2011 06 10 오후 1 38 13 ...

Reviews: