4 Alignment and Adjustments
4-4
AP17K*/AP17J*
4-2-7 Parallelogram Adjustment
CONDITIONS
Scanning Frequency:
68 kHz/85 Hz
Display image:
Crosshatch pattern
Brightness:
Maximum
Contrast:
Maximum
Use control bar after selecting “PARALLEL” in
left menu to make the image area rectangular.
Figure 4-6. Parallelogram
4-2-8 Side Pincushion Adjustment
CONDITIONS
Scanning frequency:
68 kHz/85 Hz
Display image:
Crosshatch pattern
Use control bar after selecting “PINCUSHION” in
left menu to straighten the sides of the image area.
4-2-9 Degauss
No adjustments are available for the degaussing
circuit. The degaussing circuit can effectively
function only once per 30 minutes.
4-2-10 To Delete the User Mode Data
To delete the adjustment data from the user
modes, click “@4: USER DELETE” in right ment
.
4-2-11 Save the Data
To save the adjustment data for a mode, press
“@3: ALL MODE SAVE”
in right ment
.
| C1 |, | C2 |
≤
2.0 mm, | D1 |, | D2 |
≤
2.0 mm.
Figure 4-7. Pincushion
C2
C1
D1
D2
4 mm