5-2-3 When the Indoor Unit Fan Does Not Operate. (Initial Diagnosis)
1) Checklist :
(1) Is the indoor unit fan motor properly connected with the connector (CN73)?
(2) Is the AC voltage corre c t ?
(3) Is HALL IC in indoor fan motor properly connected with the connector (CN43)?
(4) Is the running capacitor properly connected with the terminal?
2 ) Troubleshooting pro c e d u re
Troubleshooting
After unplugging out the power cord should
be reconnected within five seconds.
Does the operating lamp(Green) blink?
Does the Solid State Relay(SS71) work
properly?
Is the supply voltage of the fan
motor sufficient?
Test rod location
PCB CN73
Condition
Fan operate
AC 180V
Normal
voltage
YES
YES
YES
NO
NO
NO
Check as in the procedur “NO power parts”
Refer tp page 5-2.
Microcomputer is out of order.
PCB is
out of order.
PCB should
be replaced.
Replace MFC
Fan motor
should be replaced.
Fan motor
is out of order.
MF-C is out of order
YES
-
Test rod location
+
SS71-
SS71-
12V
Normal
Voltage
Summary of Contents for AM14A1E07
Page 4: ...Samsung Electronics 9 2 9 2 Outdoor Unit UM20A1 B1 E3 UM14A1 B1 E2...
Page 8: ...Samsung Electronics 8 3 8 1 2 AM20A1 B1 E08 DB93 00072A PCB Diagrams...
Page 10: ...Samsung Electronics 8 5 8 1 3 AM20A1 B1 E06 DB93 10628A PCB Diagrams...
Page 21: ...Samsung Electronics 6 3 Exploded Views and Parts List 6 1 b AM20A1 B1 E06...
Page 23: ...Samsung Electronics 6 5 6 2 Outdoor Unit UM20A1 B1 E3 9 9 1 9 5 6 2 a UM20A1 B1 E3...
Page 25: ...Samsung Electronics 6 7 6 2 b UM14A1 B1 E2 Exploded Views and Parts List...
Page 71: ...Samsung Electronics 2 5 2 3 2 b UM20A1 B1 E3 Product Specifications...
Page 72: ...Samsung Electronics 10 1 10 Schematic Diagrams 10 1 Indoor Unit 10 1 1 AM14A1 B1 E07...
Page 73: ...Samsung Electronics 10 2 10 1 2 AM20A1 B1 E06...
Page 74: ...Samsung Electronics 10 3 10 2 1 UM20A1 B1 E3 UM14A1 B1 E2 10 2 Outdoor Unit...