Wiring work
Selecting a solderless ring terminal
f
f
Select the solderless ring terminal depending on the nominal dimension of the power cable .
f
f
Cover and insulate the solderless ring terminal and connection part of the power cable .
Silver soldering
Nominal dimension for a cable (mm
2
)
1 .5
2 .5
4
Nominal dimension for a screw (mm)
4
4
4
4
4
B
Standard dimension (mm)
6 .6
8
6 .6
8 .5
9 .5
Allowance (mm)
±0 .2
±0 .2
±0 .2
D
Standard dimension (mm)
3 .4
4 .2
5 .6
Allowance (mm)
+0 .3
-0 .2
+0 .3
-0 .2
+0 .3
-0 .2
d1
Standard dimension (mm)
1 .7
2 .3
3 .4
Allowance (mm)
±0 .2
±0 .2
±0 .2
E
Min. (mm)
4 .1
6
6
F
Min. (mm)
6
6
5
L
Max. (mm)
16
17 .5
20
d2
Standard dimension (mm)
4 .3
4 .3
4 .3
Allowance (mm)
+ 0 .2
+ 0 .2
+ 0 .2
t
Min. (mm)
0 .7
0 .8
0 .9
ENGLISH-16
DVM PAC Mirage_IM_05674A-00_EN.indd 16
2016-04-04 오전 11:46:08