Troubleshooting
Samsung Electronics
37
Installation options for the 02 series (detailed)
Option No. for an indoor unit address: 02XXXX-1XXXXX-2XXXXX-3XXXXX
Option
SEG1
SEG2
SEG3
SEG4
SEG5
SEG6
Function
Page
Mode
-
Use of external temperature sensor /
Minimizing fan operation when thermostat
is off
Use of central control
Compensation of the
fan RPM
Indication and
details
Indication Details Indication Details
-
Indication
Details
Indication
Details
Indication
Details
Use of
external
temperature
sensor
Minimizing fan
operation when
thermostat is off
0
2
-
0
Disuse
(Cooling, Heating)
Disuse
0
Disuse
0
Disuse
(recessed
installation)
1
Use
(Cooling, Heating)
Disuse
2
Disuse
(Heating) Use (*2)
1
Use
1
High-ceiling
mode (recessed
installation)
3
Use
(Heating) Use (*2)
4
Disuse
(Cooling) Use
4
Disuse
(exposed
installation)
5
Use
(Cooling) Use
6
Disuse
(Cooling, Heating)
Use (*2)
5
High-ceiling
mode (exposed
installation)
7
Use
(Cooling, Heating)
Use (*2)
Option
SEG7
SEG8
SEG9
SEG10
SEG11
SEG12
Function
Page
Use of drain pump
Use of hot water
heater
-
EEV step when
heating stops
-
Indication and
detail
Indication Details Indication Details Indication Details
-
Indication
Details
-
1
0
Disuse
0
Disuse
0
Default
1
Use
1
Use (*3)
1
Noise
decreasing
setting
2
Use with
3 minute
delay
2
-
3
Use (*3)